메뉴 건너뛰기




Volumn 94, Issue 2, 2004, Pages 252-255

Comparison of percutaneous closure of large patent ductus arteriosus by multiple coils versus the Amplatzer duct occluder device

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTERY DIAMETER; ARTICLE; CHILD; CONTROLLED STUDY; COST EFFECTIVENESS ANALYSIS; DEVICE; FOLLOW UP; HEMODYNAMICS; HUMAN; INFANT; MAJOR CLINICAL STUDY; PATENT DUCTUS ARTERIOSUS; PRIORITY JOURNAL; TRANSLUMINAL CORONARY ANGIOPLASTY; TREATMENT OUTCOME;

EID: 3142536703     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjcard.2004.03.079     Document Type: Article
Times cited : (29)

References (20)
  • 1
    • 4243676711 scopus 로고
    • Patent ductus arteriosus
    • F.H. Adams, G.C. Emmanoulides, & T.A. Reimenscheider. Baltimore, MD: Williams & Wilkins
    • Heymann M.A. Patent ductus arteriosus. Adams F.H., Emmanoulides G.C., Reimenscheider T.A. Heart Disease in Infants, Children and Adolescents. 1994;209-223 Williams & Wilkins, Baltimore, MD
    • (1994) Heart Disease in Infants, Children and Adolescents , pp. 209-223
    • Heymann, M.A.1
  • 2
    • 0028092055 scopus 로고
    • Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils
    • Hijazi Z.M., Geggel R.L. Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple Gianturco coils. Am J Cardiol. 74:1994;925-929
    • (1994) Am J Cardiol , vol.74 , pp. 925-929
    • Hijazi, Z.M.1    Geggel, R.L.2
  • 6
    • 0033857330 scopus 로고    scopus 로고
    • Closure of the patent ductus arteriosus with the Amplatzer PDA device: Immediate results of the international clinical trial
    • Faella H.J., Hijazi Z.M. Closure of the patent ductus arteriosus with the Amplatzer PDA device immediate results of the international clinical trial. Catheter Cardiovasc Interv. 51:2000;50-54
    • (2000) Catheter Cardiovasc Interv , vol.51 , pp. 50-54
    • Faella, H.J.1    Hijazi, Z.M.2
  • 7
    • 0031539325 scopus 로고    scopus 로고
    • Evaluation of Gianturco coils for closure of large (≥3.5 mm) patent ductus arteriosus
    • Owada C.Y., Teitel D.F., Moore P. Evaluation of Gianturco coils for closure of large (≥3.5 mm) patent ductus arteriosus. J Am Coll Cardiol. 30:1997;1856-1862
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1856-1862
    • Owada, C.Y.1    Teitel, D.F.2    Moore, P.3
  • 8
    • 0033133414 scopus 로고    scopus 로고
    • The snare-assisted technique for transcatheter coil occlusion of moderate-to-large patent ductus arteriosus: Immediate and intermediate results
    • Ing F.F., Sommer R.J. The snare-assisted technique for transcatheter coil occlusion of moderate-to-large patent ductus arteriosus immediate and intermediate results. J Am Coll Cardiol. 33:1999;1710-1718
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1710-1718
    • Ing, F.F.1    Sommer, R.J.2
  • 9
    • 0035103089 scopus 로고    scopus 로고
    • Simultaneous double or triple coil technique for closure of moderate sized (≥3.0 mm) patent ductus arteriosus
    • Akagi T., Iemura M., Tananari Y., Ishii M., Yoshizawa S., Kato H. Simultaneous double or triple coil technique for closure of moderate sized (≥3.0 mm) patent ductus arteriosus. J Interv Cardiol. 14:2001;91-96
    • (2001) J Interv Cardiol , vol.14 , pp. 91-96
    • Akagi, T.1    Iemura, M.2    Tananari, Y.3    Ishii, M.4    Yoshizawa, S.5    Kato, H.6
  • 10
    • 0034858089 scopus 로고    scopus 로고
    • Bioptome-assisted simultaneous delivery of multiple coils for occlusion of the large patent ductus arteriosus
    • Kumar R.K., Krishnan M.N., Venugopal K., Sivakumar K., Anil S.R. Bioptome-assisted simultaneous delivery of multiple coils for occlusion of the large patent ductus arteriosus. Catheter Cardiovasc Interv. 54:2001;95-100
    • (2001) Catheter Cardiovasc Interv , vol.54 , pp. 95-100
    • Kumar, R.K.1    Krishnan, M.N.2    Venugopal, K.3    Sivakumar, K.4    Anil, S.R.5
  • 11
    • 0030478046 scopus 로고    scopus 로고
    • Transcatheter closure of large patent ductus arteriosus (>4 mm) with multiple Gianturco coils: Immediate and mid-term results
    • Hijazi Z.M., Geggel R.L. Transcatheter closure of large patent ductus arteriosus (>4 mm) with multiple Gianturco coils immediate and mid-term results. Heart. 76:1996;536-540
    • (1996) Heart , vol.76 , pp. 536-540
    • Hijazi, Z.M.1    Geggel, R.L.2
  • 12
    • 0034012882 scopus 로고    scopus 로고
    • Transcatheter closure of large PDA using 0.052" Gianturco coils: Controlled delivery using a bioptome catheter through a 4 French sheath
    • Grifka M.D.R.G., Jones T.K. Transcatheter closure of large PDA using 0.052" Gianturco coils controlled delivery using a bioptome catheter through a 4 French sheath. Catheter Cardiovasc Interv. 49:2000;301-306
    • (2000) Catheter Cardiovasc Interv , vol.49 , pp. 301-306
    • Grifka, M.D.R.G.1    Jones, T.K.2
  • 13
    • 0036229028 scopus 로고    scopus 로고
    • Safety and efficacy of using 0.052-inch Gianturco coil for closure of large (≥4 mm) patent ductus arteriosus
    • Huang T.C., Hsieh K.S., Lee C.L., Lin C.C. Safety and efficacy of using 0.052-inch Gianturco coil for closure of large (≥4 mm) patent ductus arteriosus. J Invasive Cardiol. 14:2002;173-177
    • (2002) J Invasive Cardiol , vol.14 , pp. 173-177
    • Huang, T.C.1    Hsieh, K.S.2    Lee, C.L.3    Lin, C.C.4
  • 14
    • 17444447441 scopus 로고    scopus 로고
    • Catheter closure of moderate-to large-sized patent ductus arteriosus using the new Amplatzer Duct Occluder: Immediate and short-term results
    • Masura J., Walsh K.P., Thanopoulos B., Chan C., Bass J., Goussous Y., Gavora P., Hijazi Z.M. Catheter closure of moderate-to large-sized patent ductus arteriosus using the new Amplatzer Duct Occluder immediate and short-term results. J Am Coll Cardiol. 31:1998;878-882
    • (1998) J Am Coll Cardiol , vol.31 , pp. 878-882
    • Masura, J.1    Walsh, K.P.2    Thanopoulos, B.3    Chan, C.4    Bass, J.5    Goussous, Y.6    Gavora, P.7    Hijazi, Z.M.8
  • 15
    • 0024558526 scopus 로고
    • Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion
    • Krichenko A., Benson L.N., Burrows P., Moes C.A.F., McLaughlin P., Freedom R.M. Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol. 63:1989;877-880
    • (1989) Am J Cardiol , vol.63 , pp. 877-880
    • Krichenko, A.1    Benson, L.N.2    Burrows, P.3    Moes, C.A.F.4    McLaughlin, P.5    Freedom, R.M.6
  • 16
    • 0035451040 scopus 로고    scopus 로고
    • Late follow-up of occlusion of the patent ductus arteriosus with the Rashkind device with emphasis on long-term efficacy and risk for infections
    • Formigari R., Toscano A., Herraiz I., Bialkowski J., Donti A., Picchio F.M., Bermudez-Canete R., Ballerini L. Late follow-up of occlusion of the patent ductus arteriosus with the Rashkind device with emphasis on long-term efficacy and risk for infections. Am J Cardiol. 88:2001;586-588
    • (2001) Am J Cardiol , vol.88 , pp. 586-588
    • Formigari, R.1    Toscano, A.2    Herraiz, I.3    Bialkowski, J.4    Donti, A.5    Picchio, F.M.6    Bermudez-Canete, R.7    Ballerini, L.8
  • 17
    • 0026004716 scopus 로고
    • Transcatheter closure of a large patent ductus arteriosus with the clamshell septal umbrella
    • Bridges N.D., Perry S.B., Parness I., Keane J.F., Lock J.E. Transcatheter closure of a large patent ductus arteriosus with the clamshell septal umbrella. J Am Coll Cardiol. 18:1991;1297-1302
    • (1991) J Am Coll Cardiol , vol.18 , pp. 1297-1302
    • Bridges, N.D.1    Perry, S.B.2    Parness, I.3    Keane, J.F.4    Lock, J.E.5
  • 18
    • 0035022606 scopus 로고    scopus 로고
    • The Sideris buttoned devices for transcatheter closure of patent ductus arteriosus
    • Sideris E.B., Rao P.S., Zamora R. The Sideris buttoned devices for transcatheter closure of patent ductus arteriosus. J Interv Cardiol. 14:2001;239-246
    • (2001) J Interv Cardiol , vol.14 , pp. 239-246
    • Sideris, E.B.1    Rao, P.S.2    Zamora, R.3
  • 19
    • 0030587275 scopus 로고    scopus 로고
    • Transcatheter patent ductus arteriosus closure in an infant using the Gianturco-Grifka Vascular Occlusion Device
    • Grifka R.G., Vincent J.A., Nihill M.R., Ing F.F., Mullins C.E. Transcatheter patent ductus arteriosus closure in an infant using the Gianturco-Grifka Vascular Occlusion Device. Am J Cardiol. 78:1996;721-723
    • (1996) Am J Cardiol , vol.78 , pp. 721-723
    • Grifka, R.G.1    Vincent, J.A.2    Nihill, M.R.3    Ing, F.F.4    Mullins, C.E.5
  • 20
    • 0036197985 scopus 로고    scopus 로고
    • Catheter closure of ductus arteriosus in adolescents and adults: What to use?
    • Hijazi Z.M. Catheter closure of ductus arteriosus in adolescents and adults what to use? Catheter Cardiovasc Interv. 55:2002;519-520
    • (2002) Catheter Cardiovasc Interv , vol.55 , pp. 519-520
    • Hijazi, Z.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.