메뉴 건너뛰기




Volumn 169, Issue 2, 2004, Pages 187-195

Reduction of wave phenomena in high-field MRI experiments using absorbing layers

Author keywords

Electromagnetics; FDTD; Numerical calculation; Radiofrequency; Simulation; Wave interference

Indexed keywords

COMPUTER SIMULATION; FINITE DIFFERENCE METHOD; IMAGE QUALITY; IONIZATION; MATHEMATICAL MODELS; SIGNAL TO NOISE RATIO; WAVE INTERFERENCE;

EID: 3142535158     PISSN: 10907807     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jmr.2004.03.027     Document Type: Article
Times cited : (14)

References (23)
  • 6
    • 0035006349 scopus 로고    scopus 로고
    • Dielectric resonances and B1 field inhomogeneity in UHFMRI: Computational analysis and experimental findings
    • Ibrahim T.S., Lee R., Abduljalil A.M., Baertlein B.A., Robitaille P.-M.L. Dielectric resonances and B1 field inhomogeneity in UHFMRI: computational analysis and experimental findings. Magn. Reson. Imag. 19:2001;219-226.
    • (2001) Magn. Reson. Imag. , vol.19 , pp. 219-226
    • Ibrahim, T.S.1    Lee, R.2    Abduljalil, A.M.3    Baertlein, B.A.4    Robitaille, P.-M.L.5
  • 7
    • 0033945956 scopus 로고    scopus 로고
    • Sensitivity and power deposition in a high-field imaging experiment
    • Hoult D.I. Sensitivity and power deposition in a high-field imaging experiment. J. Magn. Reson. Imag. 12:2000;46-67.
    • (2000) J. Magn. Reson. Imag. , vol.12 , pp. 46-67
    • Hoult, D.I.1
  • 9
    • 0035685766 scopus 로고    scopus 로고
    • Effect of RF coil excitation on field inhomogeneity at ultra high fields: A field optimized TEM resonator
    • Ibrahim T.S., Lee R., Baertlein B.A., Abduljalil A.M., Zhu H., Robitaille P.-M.L. Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. Magn. Reson. Imag. 19:2001;1339-1347.
    • (2001) Magn. Reson. Imag. , vol.19 , pp. 1339-1347
    • Ibrahim, T.S.1    Lee, R.2    Baertlein, B.A.3    Abduljalil, A.M.4    Zhu, H.5    Robitaille, P.-M.L.6
  • 10
    • 0031865774 scopus 로고    scopus 로고
    • A spiral volume coil for improved RF field homogeneity at high static magnetic field strength
    • Alsop D.C., Connick T.J., Mizsei G. A spiral volume coil for improved RF field homogeneity at high static magnetic field strength. Magn. Reson. Med. 40:1998;49-54.
    • (1998) Magn. Reson. Med. , vol.40 , pp. 49-54
    • Alsop, D.C.1    Connick, T.J.2    Mizsei, G.3
  • 11
    • 0026567364 scopus 로고
    • Reduction of RF penetration effects in high field imaging
    • Foo T.K.F., Hayes C.E., Kang Y.W. Reduction of RF penetration effects in high field imaging. Magn. Reson. Med. 23:1992;287-301.
    • (1992) Magn. Reson. Med. , vol.23 , pp. 287-301
    • Foo, T.K.F.1    Hayes, C.E.2    Kang, Y.W.3
  • 14
    • 0034900050 scopus 로고    scopus 로고
    • Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: Experimental and theoretical dependence on sample properties
    • Alecci M., Collins C.M., Smith M.B., Jezzard P. Radio frequency magnetic field mapping of a 3 Tesla birdcage coil: experimental and theoretical dependence on sample properties. Magn. Reson. Med. 46:2001;379-385.
    • (2001) Magn. Reson. Med. , vol.46 , pp. 379-385
    • Alecci, M.1    Collins, C.M.2    Smith, M.B.3    Jezzard, P.4
  • 16
    • 0018190215 scopus 로고
    • RF magnetic field penetration, phase shift and power dissipation in biological tissue: Implications for NMR imaging
    • Bottomley P.A., Andrew E.R. RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging. Phys. Med. Biol. 23:1978;630-643.
    • (1978) Phys. Med. Biol. , vol.23 , pp. 630-643
    • Bottomley, P.A.1    Andrew, E.R.2
  • 17
    • 84894021661 scopus 로고
    • Numerical solution of initial boundary value problems involving Maxwell's equations in isotropic media
    • Yee K.S. Numerical solution of initial boundary value problems involving Maxwell's equations in isotropic media. IEEE Trans. Ant. Propag. 14:1966;302-307.
    • (1966) IEEE Trans. Ant. Propag. , vol.14 , pp. 302-307
    • Yee, K.S.1
  • 19
    • 0035088728 scopus 로고    scopus 로고
    • Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil
    • Collins C.M., Smith M.B. Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil. Magn. Reson. Med. 45:2001;684-691.
    • (2001) Magn. Reson. Med. , vol.45 , pp. 684-691
    • Collins, C.M.1    Smith, M.B.2
  • 20
    • 0033770165 scopus 로고    scopus 로고
    • Computational analysis of the high pass birdcage resonator: Finite difference time domain simulations for high-field MRI
    • Ibrahim T.S., Lee R., Baertlein B.A., Yu Y., Robitaille P.-M.L. Computational analysis of the high pass birdcage resonator: finite difference time domain simulations for high-field MRI. Magn. Reson. Imag. 18:2000;835-843.
    • (2000) Magn. Reson. Imag. , vol.18 , pp. 835-843
    • Ibrahim, T.S.1    Lee, R.2    Baertlein, B.A.3    Yu, Y.4    Robitaille, P.-M.L.5
  • 22
    • 0034405181 scopus 로고    scopus 로고
    • The principle of reciprocity in signal strength calculations - A mathematical guide
    • Hoult D.I. The principle of reciprocity in signal strength calculations - a mathematical guide. Conc. Magn. Reson. 12(4):2000;173-187.
    • (2000) Conc. Magn. Reson. , vol.12 , Issue.4 , pp. 173-187
    • Hoult, D.I.1
  • 23
    • 28044459877 scopus 로고
    • A perfectly matched layer for the absorption of electromagnetic waves
    • Berenger J. A perfectly matched layer for the absorption of electromagnetic waves. J. Comp. Phys. 114:1994;185-200.
    • (1994) J. Comp. Phys. , vol.114 , pp. 185-200
    • Berenger, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.