1
-
-
0019027112
-
Estimation of rate of heat release by means of oxygen-consumption measurements
-
C. Huggett Estimation of rate of heat release by means of oxygen-consumption measurements Fire Mater. 4 1980 61 65
-
(1980)
Fire Mater.
, vol.4
, pp. 61-65
-
-
Huggett, C.1
-
2
-
-
0039780997
-
Fire safety of passenger trains: A review of current approaches and of new concepts
-
National Institute of Standards and Technology, Maryland, USA
-
R.D. Peacock, R.W. Bukowski, W.W. Jones, P.A. Reneke, V. Babrauskas, J.E. Brown, Fire safety of passenger trains: a review of current approaches and of new concepts, NIST Technical Note 1406, National Institute of Standards and Technology, Maryland, USA, 1994.
-
(1994)
NIST Technical Note
, vol.1406
-
-
Peacock, R.D.1
Bukowski, R.W.2
Jones, W.W.3
Reneke, P.A.4
Babrauskas, V.5
Brown, J.E.6
-
3
-
-
14744292069
-
Aspect of fires for factories in Hong Kong
-
W.K. Chow, and C. Cheung Aspect of fires for factories in Hong Kong J. Appl. Fire Sci. 5 1 1996 17 32
-
(1996)
J. Appl. Fire Sci.
, vol.5
, Issue.1
, pp. 17-32
-
-
Chow, W.K.1
Cheung, C.2
-
5
-
-
31344449204
-
U. Göransson Model, based on cone calorimeter results, for explaining the heat release rate growth of tests in a very large room
-
Interscience, London, UK
-
U. Göransson Model, based on cone calorimeter results, for explaining the heat release rate growth of tests in a very large room, Interflam'93 - Proceedings of Sixth International Interflam Conference, Interscience, London, UK, 1993, pp. 39-47
-
(1993)
Interflam'93 - Proceedings of Sixth International Interflam Conference
, pp. 39-47
-
-
-
7
-
-
33646513576
-
Usage of ISO 5660 data in UK railway standards and fire safety cases
-
Paper 3, Fire Hazards, Testing, Materials and Products 13 March 1997, Rapra Technology Ltd, Shawburry, Shrewsbury, Shropshire, UK
-
G.J. Duggan, Usage of ISO 5660 data in UK railway standards and fire safety cases, Paper 3, Fire Hazards, Testing, Materials and Products, Proceedings of a One Day Conference, 13 March 1997, Rapra Technology Ltd, Shawburry, Shrewsbury, Shropshire, UK, 1997.
-
(1997)
Proceedings of a One Day Conference
-
-
Duggan, G.J.1
-
8
-
-
31344467710
-
Fire safety in train vehicle: Design based on accidental fire or arson fire?
-
W.K. Chow Fire safety in train vehicle: design based on accidental fire or arson fire? The Green Cross March/April 2004 7
-
(2004)
The Green Cross
, vol.MARCH-APRIL
, pp. 7
-
-
Chow, W.K.1
-
9
-
-
31344461244
-
Fire sizes in railway passenger saloons
-
E.S. Kim Korean Institute of Fire Science and Engineering*et al.
-
V.P. Dowling, and N. White Fire sizes in railway passenger saloons, E.S. Kim Proceedings of the Sixth Asia-Oceania Symposium on Fire Science and Technology, 17-20 March 2004, Daegu, Korea 2004 Korean Institute of Fire Science and Engineering 602 611
-
(2004)
Proceedings of the Sixth Asia-Oceania Symposium on Fire Science and Technology, 17-20 March 2004, Daegu, Korea
, pp. 602-611
-
-
Dowling, V.P.1
White, N.2
-
10
-
-
38249019761
-
Methods to characterize heat release rate data
-
F.W. Mowrer, and B. Williamson Methods to characterize heat release rate data Fire Safety J. 16 1990 367 387
-
(1990)
Fire Safety J.
, vol.16
, pp. 367-387
-
-
Mowrer, F.W.1
Williamson, B.2
-
11
-
-
0037840326
-
On the superposition of heat release rate for polymeric materials
-
W.K. Chow, and H.W. Au Yeung On the superposition of heat release rate for polymeric materials Arch. Sci. Rev. 46 2 2003 145 150
-
(2003)
Arch. Sci. Rev.
, vol.46
, Issue.2
, pp. 145-150
-
-
Chow, W.K.1
Au, W.Y.H.2
-
12
-
-
0036664068
-
Assessment on heat release rate of furniture foam arrangement by a cone calorimeter
-
W.K. Chow Assessment on heat release rate of furniture foam arrangement by a cone calorimeter J. Fire Sci. 20 4 2002 319 328
-
(2002)
J. Fire Sci.
, vol.20
, Issue.4
, pp. 319-328
-
-
Chow, W.K.1
-
14
-
-
0027632154
-
Combustion behaviour of polyurethane flexible foams under cone calorimeter test conditions
-
R. Vanspeybroeck, P. Van Hees, and P. Vandevelde Combustion behaviour of polyurethane flexible foams under cone calorimeter test conditions Fire Mater. 17 1993 155 166
-
(1993)
Fire Mater.
, vol.17
, pp. 155-166
-
-
Vanspeybroeck, R.1
Van Hees, P.2
Vandevelde, P.3
-
16
-
-
0004171178
-
-
ISO 9705: 1993(E) International Standards for Organization, Geneva, Switzerland
-
ISO 9705: 1993(E), Fire Tests - Full-scale Room Test for Surface Products, International Standards for Organization, Geneva, Switzerland, 1993.
-
(1993)
Fire Tests - Full-scale Room Test for Surface Products
-
-
-
17
-
-
0347496080
-
The single burning item (SBI) test, the Euro classes and transitional arrangement
-
Interscience Communications London, UK
-
D.A. Smith, and K. Shaw The single burning item (SBI) test, the Euro classes and transitional arrangement Proceedings of Interflam'99, 29 June-1 July, 1999, Edinburgh, UK 1999 Interscience Communications London, UK 1 9
-
(1999)
Proceedings of Interflam'99, 29 June-1 July, 1999, Edinburgh, UK
, pp. 1-9
-
-
Smith, D.A.1
Shaw, K.2
-
19
-
-
10444236854
-
-
NIST GCR 01-810, National Institute of Standards and Technology, US Department of Commerce, USA
-
P.A. Friday, F.W. Mowrer, Comparison of FDS Model Predictions with FM/SNL Fire Test Data, NIST GCR 01-810, National Institute of Standards and Technology, US Department of Commerce, USA, 2001.
-
(2001)
Comparison of FDS Model Predictions with FM/SNL Fire Test Data
-
-
Friday, P.A.1
Mowrer, F.W.2
-
20
-
-
31344475000
-
Conducting a full-scale experiment on a railway passenger car
-
E.S. Kim Korean Institute of Fire Science and Engineering*et al.
-
N. White, and V.P. Dowling Conducting a full-scale experiment on a railway passenger car E.S. Kim Proceedings of the Sixth Asia-Oceania Symposium on Fire Science and Technology, 17-20 March 2004, Daegu, Korea 2004 Korean Institute of Fire Science and Engineering 591 601
-
(2004)
Proceedings of the Sixth Asia-Oceania Symposium on Fire Science and Technology, 17-20 March 2004, Daegu, Korea
, pp. 591-601
-
-
White, N.1
Dowling, V.P.2
|