메뉴 건너뛰기




Volumn 61, Issue 2, 2006, Pages 163-173

Diagnostic accuracy of fracture detection in suspected non-accidental injury: The effect of edge enhancement and digital display on observer performance

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BONE RADIOGRAPHY; CHILD; CLINICAL ARTICLE; COMPUTER ASSISTED RADIOGRAPHY; CONTRAST ENHANCEMENT; DIAGNOSTIC ACCURACY; FRACTURE; HUMAN; HUMAN TISSUE; IMAGE DISPLAY; IMAGE ENHANCEMENT; IMAGE QUALITY; MUSCULOSKELETAL DIAGNOSIS; OBSERVER VARIATION; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; RECEIVER OPERATING CHARACTERISTIC; SCORING SYSTEM; SENSITIVITY AND SPECIFICITY; SOFT TISSUE RADIOGRAPHY; STANDARD; STATISTICAL SIGNIFICANCE; STUDENT T TEST; TRABECULAR BONE;

EID: 31344463741     PISSN: 00099260     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.crad.2005.09.004     Document Type: Article
Times cited : (11)

References (22)
  • 1
    • 31344436468 scopus 로고    scopus 로고
    • American College of Radiology Practice Guideline for Skeletal Surveys in Children (Res 22) Revised 2001 (Res 31) (Accessed February 2005)
    • American College of Radiology Practice Guideline for Skeletal Surveys in Children 1997 (Res 22) Revised 2001 (Res 31) http://www.acr.org/ departments/stand_accred/standards/pdf/skeletal_survey.pdf (Accessed February 2005).
    • (1997)
  • 4
    • 0024422658 scopus 로고
    • High frequency edge enhancement in the detection of fine pulmonary lines: Parity between storage phosphor digital images and conventional chest radiography
    • J.W. Oestmann R. Greene J.R. Rubens, et al. High frequency edge enhancement in the detection of fine pulmonary lines: Parity between storage phosphor digital images and conventional chest radiography Invest Radiol 24 1989 643-646
    • (1989) Invest Radiol , vol.24 , pp. 643-646
    • Oestmann, J.W.1    Greene, R.2    Rubens, J.R.3
  • 5
    • 0028113868 scopus 로고
    • Evaluation of the injured cervical spine: Comparison of conventional and storage phosphor radiography with a hybrid cassette
    • A.J. Wilson F.A. Mann O.C. West K.W. McEnery W.A. Murphy Jr Evaluation of the injured cervical spine: Comparison of conventional and storage phosphor radiography with a hybrid cassette Radiology 193 1994 419-422
    • (1994) Radiology , vol.193 , pp. 419-422
    • Wilson, A.J.1    Mann, F.A.2    West, O.C.3    McEnery, K.W.4    Murphy Jr., W.A.5
  • 6
    • 0025180192 scopus 로고
    • Storage phosphor versus screen-film radiography: Effect of varying exposure parameters and unsharp mask filtering on the detectability of cortical bone defects
    • M. Prokop M. Galanski J.W. Oestmann, et al. Storage phosphor versus screen-film radiography: Effect of varying exposure parameters and unsharp mask filtering on the detectability of cortical bone defects Radiology 177 1990 109-113
    • (1990) Radiology , vol.177 , pp. 109-113
    • Prokop, M.1    Galanski, M.2    Oestmann, J.W.3
  • 7
    • 0030176145 scopus 로고    scopus 로고
    • Clinical experiences with computed radiography
    • F.E. Lindhardt Clinical experiences with computed radiography Eur J Radiol 22 1996 175-185
    • (1996) Eur J Radiol , vol.22 , pp. 175-185
    • Lindhardt, F.E.1
  • 8
    • 0029245685 scopus 로고
    • A comparison of hard and soft copies processed with linear conversion and nonlinear conversion of skeletal fractures - A preliminary study
    • T. Kaji M. Katayama S. Kosuda S. Kusano A comparison of hard and soft copies processed with linear conversion and nonlinear conversion of skeletal fractures - a preliminary study J Dig Imaging 8 1995 45-50
    • (1995) J Dig Imaging , vol.8 , pp. 45-50
    • Kaji, T.1    Katayama, M.2    Kosuda, S.3    Kusano, S.4
  • 9
    • 0029977636 scopus 로고    scopus 로고
    • Evaluation of soft-tissue foreign bodies: Comparing conventional plain film radiography, computed radiography printed on film, and computed radiography displayed on a computer workstation
    • B. Reiner E. Siegel T. McLaurin et al. Evaluation of soft-tissue foreign bodies: Comparing conventional plain film radiography, computed radiography printed on film, and computed radiography displayed on a computer workstation AJR Am J Roentgenol 167 1996 141-144
    • (1996) AJR Am J Roentgenol , vol.167 , pp. 141-144
    • Reiner, B.1    Siegel, E.2    McLaurin, T.3
  • 10
    • 0033755001 scopus 로고    scopus 로고
    • Interpretation of emergency department radiographs: A comparison of emergency medicine physicians with radiologists, residents with faculty, and film with digital display
    • J. Eng W.K. Mysko G.E.R. Weller et al. Interpretation of emergency department radiographs: A comparison of emergency medicine physicians with radiologists, residents with faculty, and film with digital display AJR Am J Roentgenol 175 2000 1233-1238
    • (2000) AJR Am J Roentgenol , vol.175 , pp. 1233-1238
    • Eng, J.1    Mysko, W.K.2    Weller, G.E.R.3
  • 11
    • 31344466029 scopus 로고    scopus 로고
    • Guidelines on autopsy practice: Report of a working group of the Royal College of Pathologists. Appendix 7: Guidelines for autopsy investigation in post-neonatal infant deaths or sudden unexpected deaths in infancy. The Royal College of Pathologists; (accessed February 2005)
    • Guidelines on autopsy practice: Report of a working group of the Royal College of Pathologists. Appendix 7: Guidelines for autopsy investigation in post-neonatal infant deaths or sudden unexpected deaths in infancy. The Royal College of Pathologists; 2002 http:// www.rcpath.org/resources/pdf/appendix_7.pdf (accessed February 2005).
    • (2002)
  • 12
    • 0022470978 scopus 로고
    • ROC methodology in radiological imaging
    • C.E. Metz ROC methodology in radiological imaging Invest Radiol 21 1986 720-733
    • (1986) Invest Radiol , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 13
    • 0029380521 scopus 로고
    • Degeneracy and discrete receiver operating characteristic rating data
    • D.D. Dorfman K.S. Berbaum Degeneracy and discrete receiver operating characteristic rating data Acad Radiol 2 1995 907-915
    • (1995) Acad Radiol , vol.2 , pp. 907-915
    • Dorfman, D.D.1    Berbaum, K.S.2
  • 14
    • 0031981340 scopus 로고    scopus 로고
    • Reporting requirements for skeletal digital radiography: Comparison of soft copy and hard copy presentation
    • P.J. O'Connor A.G. Davies R.C. Fowler et al. Reporting requirements for skeletal digital radiography: Comparison of soft copy and hard copy presentation Radiology 207 1998 249-254
    • (1998) Radiology , vol.207 , pp. 249-254
    • O'Connor, P.J.1    Davies, A.G.2    Fowler, R.C.3
  • 15
    • 0026698902 scopus 로고
    • Evaluation of a digital workstation for interpreting neonatal examinations
    • E.A. Franken K.S. Berbaum S.M. Marley et al. Evaluation of a digital workstation for interpreting neonatal examinations Invest Radiol 27 1992 732-737
    • (1992) Invest Radiol , vol.27 , pp. 732-737
    • Franken, E.A.1    Berbaum, K.S.2    Marley, S.M.3
  • 16
    • 0031922050 scopus 로고    scopus 로고
    • Radiology report times: Impact of picture archiving and communication systems
    • S. Bryan G. Weatherburn J. Watkins et al. Radiology report times: Impact of picture archiving and communication systems AJR Am J Roentgenol 170 1998 1153-1159
    • (1998) AJR Am J Roentgenol , vol.170 , pp. 1153-1159
    • Bryan, S.1    Weatherburn, G.2    Watkins, J.3
  • 17
    • 0026223056 scopus 로고
    • Effects of optimization and image processing in digital chest radiography: An ROC study with an anthropomorphic phantom
    • S. Kheddache L.G. Mansson J.E. Angelhed L. Denbratt B. Gottfridsson D. Schlossman Effects of optimization and image processing in digital chest radiography: An ROC study with an anthropomorphic phantom Eur J Radiol 13 1991 143-150
    • (1991) Eur J Radiol , vol.13 , pp. 143-150
    • Kheddache, S.1    Mansson, L.G.2    Angelhed, J.E.3    Denbratt, L.4    Gottfridsson, B.5    Schlossman, D.6
  • 18
    • 0026570759 scopus 로고
    • Receiver-operating-characteristic study of chest radiographs in children: Digital hard copy film vs 2KX2K soft copy images
    • M. Razavi J.W. Sayre R.K. Taira et al. Receiver-operating-characteristic study of chest radiographs in children: Digital hard copy film vs 2KX2K soft copy images AJR Am J Roentgenol 158 1992 443-448
    • (1992) AJR Am J Roentgenol , vol.158 , pp. 443-448
    • Razavi, M.1    Sayre, J.W.2    Taira, R.K.3
  • 19
    • 0029157045 scopus 로고
    • Imaging systems evaluation: Effect of subtle cases on the design and analysis of receiver operating characteristic studies
    • H.E. Rockette J.L. King J.L. Medina H.B. Eisen M.L. Brown D. Gur Imaging systems evaluation: Effect of subtle cases on the design and analysis of receiver operating characteristic studies AJR Am J Roentgenol 165 1995 679-683
    • (1995) AJR Am J Roentgenol , vol.165 , pp. 679-683
    • Rockette, H.E.1    King, J.L.2    Medina, J.L.3    Eisen, H.B.4    Brown, M.L.5    Gur, D.6
  • 20
    • 0031740171 scopus 로고    scopus 로고
    • Skeletal surveys for child abuse: Comparison of interpretation using digitised images and screen-film radiographs
    • D.C. Youmens S. Don C. Hildebolt G.D. Shackelford G.D. Luker W.H. McAllister Skeletal surveys for child abuse: Comparison of interpretation using digitised images and screen-film radiographs AJR Am J Roentgenol 171 1998 1415-1419
    • (1998) AJR Am J Roentgenol , vol.171 , pp. 1415-1419
    • Youmens, D.C.1    Don, S.2    Hildebolt, C.3    Shackelford, G.D.4    Luker, G.D.5    McAllister, W.H.6
  • 21
    • 0024462154 scopus 로고
    • Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data
    • D.P. Chakraborty Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data Med Phys 16 1989 561-568
    • (1989) Med Phys , vol.16 , pp. 561-568
    • Chakraborty, D.P.1
  • 22
    • 0025269074 scopus 로고
    • Free-response methodology: Alternate analysis and a new observer-performance experiment
    • D.P. Chakraborty L.H. Winter Free-response methodology: Alternate analysis and a new observer-performance experiment Radiology 174 1990 873-881
    • (1990) Radiology , vol.174 , pp. 873-881
    • Chakraborty, D.P.1    Winter, L.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.