메뉴 건너뛰기




Volumn 37, Issue 2, 2006, Pages 194-202

Erratum to "Salvage of failed dynamic hip screw fixation of intertrochanteric fractures" [Injury 37 (2) (2006) 194-202] (DOI:10.1016/j.injury.2005.09.011);Salvage of failed dynamic hip screw fixation of intertrochanteric fractures

Author keywords

Failed DHS; Intertrochanteric fracture; Trochanteric nonunion

Indexed keywords

ACETABULUM; ADULT; AGED; ARTICLE; AVASCULAR NECROSIS; BONE TRANSPLANTATION; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FEMUR HEAD; FEMUR INTERTROCHANTERIC FRACTURE; FOLLOW UP; HUMAN; MALE; OSTEOSYNTHESIS; OSTEOTOMY; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PROSTHESIOLOGY; REOPERATION; TOTAL HIP PROSTHESIS;

EID: 31344450712     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2006.02.013     Document Type: Erratum
Times cited : (52)

References (14)
  • 1
    • 0242574938 scopus 로고    scopus 로고
    • Valgus osteotomy for malunion and nonunion of trochanteric fractures
    • J. Bartonicek, J. Skala-Rosenbaum, and P. Dousa Valgus osteotomy for malunion and nonunion of trochanteric fractures J Orthop Trauma 17 9 2003 606 612
    • (2003) J Orthop Trauma , vol.17 , Issue.9 , pp. 606-612
    • Bartonicek, J.1    Skala-Rosenbaum, J.2    Dousa, P.3
  • 2
    • 0031881762 scopus 로고    scopus 로고
    • RAB-plate versus Richards CHS plate for unstable trochanteric hip fractures: A randomised study of 233 patients with 1-year follow-up
    • R. Buciuto, B. Uhlin, S. Hammerby, and R. Hammer RAB-plate versus Richards CHS plate for unstable trochanteric hip fractures: a randomised study of 233 patients with 1-year follow-up Acta Orthop Scand 69 1998 25 28
    • (1998) Acta Orthop Scand , vol.69 , pp. 25-28
    • Buciuto, R.1    Uhlin, B.2    Hammerby, S.3    Hammer, R.4
  • 3
    • 0016829044 scopus 로고
    • The treatment of trochanteric hip fractures using a compression screw
    • M.L. Ecker, J.J. Joyce III, and E.J. Kohl The treatment of trochanteric hip fractures using a compression screw J Bone Joint Surg 57(A) 1975 23 27
    • (1975) J Bone Joint Surg , vol.57 , pp. 23-27
    • Ecker, M.L.1    Joyce III, J.J.2    Kohl, E.J.3
  • 4
    • 0038672156 scopus 로고    scopus 로고
    • Hip arthroplasty for salvage of failed treatment of intertrochanteric hip fractures
    • G.J. Haidukewych, and D.J. Berry Hip arthroplasty for salvage of failed treatment of intertrochanteric hip fractures J Bone Joint Surg 8(A) 2003 899 904
    • (2003) J Bone Joint Surg , vol.8 , pp. 899-904
    • Haidukewych, G.J.1    Berry, D.J.2
  • 5
    • 0038755516 scopus 로고    scopus 로고
    • Salvage of failed internal fixation of intertrochanteric hip fractures
    • G.J. Haidukewych, and D.J. Berry Salvage of failed internal fixation of intertrochanteric hip fractures Clin Orthop 412 2003 184 188
    • (2003) Clin Orthop , vol.412 , pp. 184-188
    • Haidukewych, G.J.1    Berry, D.J.2
  • 6
    • 21844436565 scopus 로고    scopus 로고
    • Salvage of failed treatment of hip fractures
    • G.J. Haidukewych, and D.J. Berry Salvage of failed treatment of hip fractures J Am Acad Orthop Surg 13 2005 101 109
    • (2005) J Am Acad Orthop Surg , vol.13 , pp. 101-109
    • Haidukewych, G.J.1    Berry, D.J.2
  • 7
    • 0018865818 scopus 로고
    • Internal fixation of intertrochanteric hip fractures: A clinical and biomechanical study
    • R.R. Jacobs, O. McClain, and H.J. Armstrong Internal fixation of intertrochanteric hip fractures: a clinical and biomechanical study Clin Orthop 146 1980 62 70
    • (1980) Clin Orthop , vol.146 , pp. 62-70
    • Jacobs, R.R.1    McClain, O.2    Armstrong, H.J.3
  • 8
    • 0018861236 scopus 로고
    • Mechanics of the treatment of hip injuries
    • H. Kaufer Mechanics of the treatment of hip injuries Clin Orthop 146 1980 53 61
    • (1980) Clin Orthop , vol.146 , pp. 53-61
    • Kaufer, H.1
  • 9
    • 0032059914 scopus 로고    scopus 로고
    • Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the gamma nail and compression hip screw
    • J.E. Madsen, L. Naess, and A.K. Aune Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the gamma nail and compression hip screw J Orthop Trauma 12 4 1998 241 248
    • (1998) J Orthop Trauma , vol.12 , Issue.4 , pp. 241-248
    • Madsen, J.E.1    Naess, L.2    Aune, A.K.3
  • 10
    • 0002463766 scopus 로고
    • Intertrochanteric osteotomy: Indication, preoperative planning, technique
    • J. Schatzker Springer-Verlag Berlin
    • M.E. Müller Intertrochanteric osteotomy: indication, preoperative planning, technique J. Schatzker The intertrochanteric osteotomy 1984 Springer-Verlag Berlin
    • (1984) The Intertrochanteric Osteotomy
    • Müller, M.E.1
  • 12
    • 0023789202 scopus 로고
    • The anatomical basis of femoral component design
    • P.C. Noble, J.W. Alexander, and L.J. Lindhal The anatomical basis of femoral component design Clin Orthop 235 1988 148 165
    • (1988) Clin Orthop , vol.235 , pp. 148-165
    • Noble, P.C.1    Alexander, J.W.2    Lindhal, L.J.3
  • 13
    • 31344463608 scopus 로고    scopus 로고
    • Subtrochanteric valgus osteotomy fixation by single or double angled plate
    • G.Z. Said, M.A. Gaballa, H.Z. Said, and H. Elkady Subtrochanteric valgus osteotomy fixation by single or double angled plate Pan Arab J Orthop Trauma 3 2 1999 103 107
    • (1999) Pan Arab J Orthop Trauma , vol.3 , Issue.2 , pp. 103-107
    • Said, G.Z.1    Gaballa, M.A.2    Said, H.Z.3    Elkady, H.4
  • 14
    • 0031966436 scopus 로고    scopus 로고
    • Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture
    • C.C. Wu, C.H. Shih, W.J. Chen, and C.L. Tai Treatment of cutout of a lag screw of a dynamic hip screw in an intertrochanteric fracture Arch Orthop Trauma Surg 117 1998 193 196
    • (1998) Arch Orthop Trauma Surg , vol.117 , pp. 193-196
    • Wu, C.C.1    Shih, C.H.2    Chen, W.J.3    Tai, C.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.