Volumn 20, Issue 1, 2006, Pages 64-67

Development of a safe guidewire

Author keywords

Central venous catheter; Complication; Guidewire

Indexed keywords

ARTICLE; CENTRAL VENOUS CATHETER; CENTRAL VENOUS CATHETERIZATION; CONTROLLED STUDY; DEVICE REMOVAL; EQUIPMENT DESIGN; GENERAL ANESTHESIA; GUIDE WIRE; HUMAN; INTERMETHOD COMPARISON; INTERNAL JUGULAR VEIN; MAJOR CLINICAL STUDY; NEEDLE; RISK REDUCTION; VEIN PUNCTURE;

EID: 31144465315     PISSN: 09138668     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00540-005-0361-x     Document Type: Article
Times cited : (8)

References (10)
  • 1
    • 0023285862 scopus 로고
    • Transvenous misplacement and loop formation of spring guide wire
    • L Kjeldsem 1987 Transvenous misplacement and loop formation of spring guide wire Anesthesia 42 215
    • (1987) Anesthesia , vol.42 , pp. 215
    • Kjeldsem, L.1
  • 3
    • 0033169072 scopus 로고    scopus 로고
    • Subclavian central venous catheterization complicated by guide wire looping and entrapment
    • 10.1016/S0736-4679(99)00067-0 1:STN:280:DyaK1MzlvV2isA%3D%3D 10431965
    • HE Wang TA Sweeney 1999 Subclavian central venous catheterization complicated by guide wire looping and entrapment J Emerg Med 17 721-724 10.1016/S0736-4679(99)00067-0 1:STN:280:DyaK1MzlvV2isA%3D%3D 10431965
    • (1999) J Emerg Med , vol.17 , pp. 721-724
    • Wang, H.E.1    Sweeney, T.A.2
  • 4
    • 0344231110 scopus 로고
    • Intravascular breakage of Seldinger spring guide wires
    • 1:STN:280:CC2D383kslA%3D 13881174
    • C Cope 1962 Intravascular breakage of Seldinger spring guide wires JAMA 180 10611:STN:280:CC2D383kslA%3D 13881174
    • (1962) JAMA , vol.180 , pp. 1061
    • Cope, C.1
  • 5
    • 8244262042 scopus 로고    scopus 로고
    • Breakage of Seldinger spring guide wire during percutaneous catheterization of a subclavian vein
    • 1:STN:280:ByiB2cbnsVw%3D 9095611
    • T Shimamoto T Arai 1997 Breakage of Seldinger spring guide wire during percutaneous catheterization of a subclavian vein Masui 46 376-378 1:STN:280:ByiB2cbnsVw%3D 9095611
    • (1997) Masui , vol.46 , pp. 376-378
    • Shimamoto, T.1    Arai, T.2
  • 6
    • 0029421005 scopus 로고    scopus 로고
    • A pilot/introducer needle for central vein cannulation
    • T Suzuki M Kanazawa Y Kinefuchi et al. 1996 A pilot/introducer needle for central vein cannulation Tokai J Exp Clin Med 20 223-225
    • (1996) Tokai J Exp Clin Med , vol.20 , pp. 223-225
    • Suzuki, T.1    Kanazawa, M.2    Kinefuchi, Y.3
  • 7
    • 0344517306 scopus 로고    scopus 로고
    • Improvement of Safe Guide®: A further up-grade of the central venous catheterization kit
    • K Ito T Suzuki H Fukuyama et al. 1998 Improvement of Safe Guide®: A further up-grade of the central venous catheterization kit Rinsho Masui 6 857-859
    • (1998) Rinsho Masui , vol.6 , pp. 857-859
    • Ito, K.1    Suzuki, T.2    Fukuyama, H.3
  • 8
    • 0345851252 scopus 로고    scopus 로고
    • A case of guide wire trouble using Safe Guide
    • T Suzuki J Hasegawa M Nitta et al. 2000 A case of guide wire trouble using Safe Guide Cir Cont 21 201-204
    • (2000) Cir Cont , vol.21 , pp. 201-204
    • Suzuki, T.1    Hasegawa, J.2    Nitta, M.3
  • 9
    • 2542488180 scopus 로고    scopus 로고
    • Injured and liability related to central vascular catheters
    • 10.1097/00000542-200406000-00013 15166560
    • K Domino TA Bowdle KL Posner et al. 2004 Injured and liability related to central vascular catheters Anesthesiology 100 1411-1418 10.1097/ 00000542-200406000-00013 15166560
    • (2004) Anesthesiology , vol.100 , pp. 1411-1418
    • Domino, K.1    Bowdle, T.A.2    Posner, K.A.3
  • 10
    • 0019557639 scopus 로고
    • Guide wires - A caution
    • 1:STN:280:Bi6C28zmtV0%3D 7214946
    • AJ Schwartz JC Horrow DR Jobes et al. 1981 Guide wires - a caution Crit Care Med 9 347-348 1:STN:280:Bi6C28zmtV0%3D 7214946
    • (1981) Crit Care Med , vol.9 , pp. 347-348
    • Schwartz, A.J.1    Horrow, J.C.2    Jobes, D.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.