Portable coronary active perfusion system for off-pump coronary artery bypass grafting

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; BLOOD FLOWMETRY; BLOOD PUMP; BLOOD VESSEL SHUNT; CONTROLLED STUDY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY PRESSURE; HEART ASSIST DEVICE; HEART HEMODYNAMICS; HEART INFARCTION; HEART LEFT VENTRICLE FUNCTION; HEART PERFUSION; HEART VENTRICLE ARRHYTHMIA; LEFT ANTERIOR DESCENDING CORONARY ARTERY; NONHUMAN; OFF PUMP CORONARY SURGERY; PORTABLE EQUIPMENT; PRIORITY JOURNAL; SWINE; TREATMENT OUTCOME;

EID: 31044440540     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2005.06.064     Document Type: Article
Times cited : (7)

References (10)
  • 1
    • 0036267167 scopus 로고    scopus 로고
    • Hemodynamic collapse during off-pump coronary artery bypass grafting
    • T.A. Vassiliades Jr, J.L. Nielsen, J.L. Lonquist Hemodynamic collapse during off-pump coronary artery bypass grafting Ann Thorac Surg 73 2002 1874 1879
    • (2002) Ann Thorac Surg , vol.73 , pp. 1874-1879
    • Vassiliades Jr., T.A.1    Nielsen, J.L.2    Lonquist, J.L.3
  • 2
    • 0032076551 scopus 로고    scopus 로고
    • Vertical displacement of the beating heart by the octopus tissue stabilizer: Influence on coronary flow
    • P.F. Grundeman, C. Borst, J.A. van Herwaarden, C.W. Verlaan, E.W. Jansen Vertical displacement of the beating heart by the octopus tissue stabilizer influence on coronary flow Ann Thorac Surg 65 1998 1348 1352
    • (1998) Ann Thorac Surg , vol.65 , pp. 1348-1352
    • Grundeman, P.F.1    Borst, C.2    Van Herwaarden, J.A.3    Verlaan, C.W.4    Jansen, E.W.5
  • 3
    • 0032928721 scopus 로고    scopus 로고
    • Intracoronary shunt prevents left ventricular function impairment during beating heart coronary revascularization
    • V. Lucchetti, F. Capasso, M. Caputo Intracoronary shunt prevents left ventricular function impairment during beating heart coronary revascularization Eur J Cardiothorac Surg 15 1999 255 259
    • (1999) Eur J Cardiothorac Surg , vol.15 , pp. 255-259
    • Lucchetti, V.1    Capasso, F.2    Caputo, M.3
  • 4
    • 0033840580 scopus 로고    scopus 로고
    • External shunt for off-pump coronary artery bypass grafting: Distal coronary perfusion catheter
    • H. Arai, T. Yoshida, H. Izumi, M. Sunamori External shunt for off-pump coronary artery bypass grafting distal coronary perfusion catheter Ann Thorac Surg 70 2000 681 682
    • (2000) Ann Thorac Surg , vol.70 , pp. 681-682
    • Arai, H.1    Yoshida, T.2    Izumi, H.3    Sunamori, M.4
  • 5
    • 0036384701 scopus 로고    scopus 로고
    • Preserved myocardial blood flow and oxygen supply-demand balance with active coronary perfusion during simulated off-pump coronary artery bypass grafting
    • S. Muraki, C.D. Morris, J.M. Budde Preserved myocardial blood flow and oxygen supply-demand balance with active coronary perfusion during simulated off-pump coronary artery bypass grafting J Thorac Cardiovasc Surg 123 2002 53 62
    • (2002) J Thorac Cardiovasc Surg , vol.123 , pp. 53-62
    • Muraki, S.1    Morris, C.D.2    Budde, J.M.3
  • 6
    • 0036768240 scopus 로고    scopus 로고
    • Coronary active perfusion system can maintain myocardial blood flow and tissue oxygenation
    • H. Kamiya, G. Watanabe, T. Doi Coronary active perfusion system can maintain myocardial blood flow and tissue oxygenation Eur J Cardiothorac Surg 22 2002 410 414
    • (2002) Eur J Cardiothorac Surg , vol.22 , pp. 410-414
    • Kamiya, H.1    Watanabe, G.2    Doi, T.3
  • 7
    • 26844539596 scopus 로고    scopus 로고
    • Off-pump CABG with Synchronized Arterial Flow Ensuring System (SAFE-System)
    • (in press).
    • Watanabe G, Kamiya H, Nagamine H, et al. Off-pump CABG with Synchronized Arterial Flow Ensuring System (SAFE-System) Ann Thorac Surg (in press).
    • Ann Thorac Surg
    • Watanabe, G.1    Kamiya, H.2    Nagamine, H.3
  • 8
    • 0038337849 scopus 로고    scopus 로고
    • Minimally ischemic off-pump coronary artery bypass grafting: Active perfusion-assist with nitroglycerin-supplemented blood
    • S. Muraki, M. Tsukamoto, K. Komatsu Minimally ischemic off-pump coronary artery bypass grafting active perfusion-assist with nitroglycerin-supplemented blood Ann Thorac Surg 76 2003 298 300
    • (2003) Ann Thorac Surg , vol.76 , pp. 298-300
    • Muraki, S.1    Tsukamoto, M.2    Komatsu, K.3
  • 9
    • 0036799497 scopus 로고    scopus 로고
    • Coronary perfusion methods during off-pump coronary artery bypass: Results of a randomized clinical trial
    • T.A. Vassiliades Jr, J.L. Nielsen, J.L. Lonquist Coronary perfusion methods during off-pump coronary artery bypass results of a randomized clinical trial Ann Thorac Surg 74 2002 S1383 S1389
    • (2002) Ann Thorac Surg , vol.74
    • Vassiliades Jr., T.A.1    Nielsen, J.L.2    Lonquist, J.L.3
  • 10
    • 0037237936 scopus 로고    scopus 로고
    • Miniature vibrating flow blood pump using a cross-slider mechanism for external shunt catheter
    • S. Kawano, T. Isoyama, S. Kobayashi Miniature vibrating flow blood pump using a cross-slider mechanism for external shunt catheter Artif Organs 27 2003 73 77
    • (2003) Artif Organs , vol.27 , pp. 73-77
    • Kawano, S.1    Isoyama, T.2    Kobayashi, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.