메뉴 건너뛰기




Volumn 16, Issue 1, 2006, Pages 1-10

Comparative in vitro wear testing of PEEK and UHMWPE capped metacarpophalangeal prostheses

Author keywords

Finger simulator; Metacarpophalangeal; Soaking; Titanium; UHMWPE; Wear

Indexed keywords

KETONES; LUBRICANTS; TITANIUM; WEAR RESISTANCE;

EID: 30944464464     PISSN: 09592989     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (34)

References (25)
  • 1
    • 0033769964 scopus 로고    scopus 로고
    • Implant arthroplasty of the hand: Retrospective and prospective considerations
    • R.L. Linscheid, Implant arthroplasty of the hand: retrospective and prospective considerations, Journal of Hand Surgery (American Volume) 25A (2000), 796-816.
    • (2000) Journal of Hand Surgery (American Volume) , vol.25 A , pp. 796-816
    • Linscheid, R.L.1
  • 5
    • 0027465422 scopus 로고
    • Long-term follow up of Swanson's silastic arthroplasty of the metacarpophalangeal joints in rheumatoid arthritis
    • Y.G. Wilson, P.J. Sykes and N.S. Niranjan, Long-term follow up of Swanson's silastic arthroplasty of the metacarpophalangeal joints in rheumatoid arthritis, Journal of Hand Surgery (British and European Volume) 18B (1993), 81-91.
    • (1993) Journal of Hand Surgery (British and European Volume) , vol.18 B , pp. 81-91
    • Wilson, Y.G.1    Sykes, P.J.2    Niranjan, N.S.3
  • 6
    • 0018194690 scopus 로고
    • Experience with silastic prostheses in the rheumatoid hand: A five year follow up
    • A.G. Kay, J.V. Ljeffs and J.T. Scott, Experience with silastic prostheses in the rheumatoid hand: a five year follow up, Annals of the Rheumatic Diseases 37 (1978), 255-258.
    • (1978) Annals of the Rheumatic Diseases , vol.37 , pp. 255-258
    • Kay, A.G.1    Ljeffs, J.V.2    Scott, J.T.3
  • 8
    • 0141718816 scopus 로고    scopus 로고
    • Five-year results of a new total replacement prosthesis for the finger metacarpo-phalangeal joints
    • D. Harris and J.J. Dias, Five-year results of a new total replacement prosthesis for the finger metacarpo-phalangeal joints, Journal of Hand Surgery 28B (2003), 432-438.
    • (2003) Journal of Hand Surgery , vol.28 B , pp. 432-438
    • Harris, D.1    Dias, J.J.2
  • 9
    • 0033000450 scopus 로고    scopus 로고
    • Metacarpophalangeal joint arthroplasty in rheumatoid arthritis: Results of Swanson implants and digital joint operative arthroplasty
    • M. Rittmeister, M. Porsch, M. Starker and F. Kerschbaumer, Metacarpophalangeal joint arthroplasty in rheumatoid arthritis: results of Swanson implants and digital joint operative arthroplasty, Arch. Orthop. Trauma Surg. 119 (1999), 190-194.
    • (1999) Arch. Orthop. Trauma Surg. , vol.119 , pp. 190-194
    • Rittmeister, M.1    Porsch, M.2    Starker, M.3    Kerschbaumer, F.4
  • 11
    • 0026754651 scopus 로고
    • Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy
    • M.F. Semlitsch, H. Weber, R.M. Streicher and R. Schön, Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy, Biomaterials 13 (1992), 781-788.
    • (1992) Biomaterials , vol.13 , pp. 781-788
    • Semlitsch, M.F.1    Weber, H.2    Streicher, R.M.3    Schön, R.4
  • 12
    • 0034515397 scopus 로고    scopus 로고
    • The design of a finger wear simulator and preliminary results
    • T.J. Joyce and A. Unsworth, The design of a finger wear simulator and preliminary results, Journal of Engineering in Medicine 214 (2000), 519-526.
    • (2000) Journal of Engineering in Medicine , vol.214 , pp. 519-526
    • Joyce, T.J.1    Unsworth, A.2
  • 14
    • 0020154317 scopus 로고
    • Finger joint force predictions related to design of joint replacements
    • B. Weightman and A.A. Amis, Finger joint force predictions related to design of joint replacements, Journal of Biomedical Engineering 4 (1982), 197-205.
    • (1982) Journal of Biomedical Engineering , vol.4 , pp. 197-205
    • Weightman, B.1    Amis, A.A.2
  • 15
    • 0022146688 scopus 로고
    • A microcomputer controlled hand assessment system used for clinical measurement
    • A.R. Jones, A. Unsworth and I. Haslock, A microcomputer controlled hand assessment system used for clinical measurement, Engineering in Medicine 14 (1985), 191-198.
    • (1985) Engineering in Medicine , vol.14 , pp. 191-198
    • Jones, A.R.1    Unsworth, A.2    Haslock, I.3
  • 17
    • 0035237584 scopus 로고    scopus 로고
    • In vitro comparison of the two hard-hard articulations for total hip replacements
    • C. Rieker, R. Konrad and R. Schön, In vitro comparison of the two hard-hard articulations for total hip replacements, Engineering in Medicine 215 (2001), 153-160.
    • (2001) Engineering in Medicine , vol.215 , pp. 153-160
    • Rieker, C.1    Konrad, R.2    Schön, R.3
  • 18
    • 0035482593 scopus 로고    scopus 로고
    • The wear of artificial finger joints using different lubricants in a new finger wear simulator
    • T.J. Joyce and A. Unsworth, The wear of artificial finger joints using different lubricants in a new finger wear simulator, Wear 250 (2001), 199-205.
    • (2001) Wear , vol.250 , pp. 199-205
    • Joyce, T.J.1    Unsworth, A.2
  • 19
    • 0030339156 scopus 로고    scopus 로고
    • Metal-on-metal articulation for artificial hip joints: Laboratory study and clinical results
    • R.M. Streicher, M. Semlitsch, R. Schön, H. Weber and C. Rieker, Metal-on-metal articulation for artificial hip joints: laboratory study and clinical results, Engineering in Medicine 210 (1996), 223-232.
    • (1996) Engineering in Medicine , vol.210 , pp. 223-232
    • Streicher, R.M.1    Semlitsch, M.2    Schön, R.3    Weber, H.4    Rieker, C.5
  • 20
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties - Recipient of the 1999 HAP Paul Award
    • O. Muratoglu, C. Bragdon, D. O'Connor, M. Jasty and W Harris, A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties - Recipient of the 1999 HAP Paul Award, Journal of Arthroplasty 16 (2001), 149-160.
    • (2001) Journal of Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.1    Bragdon, C.2    O'Connor, D.3    Jasty, M.4    Harris, W.5
  • 22
    • 0032201988 scopus 로고    scopus 로고
    • Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement
    • A. Wang, R. Lin, V.K. Polineni, A. Essner, C. Stark and J.H. Dumbleton, Carbon fiber reinforced polyether ether ketone composite as a bearing surface for total hip replacement, Tribology International 31 (1998), 661-667.
    • (1998) Tribology International , vol.31 , pp. 661-667
    • Wang, A.1    Lin, R.2    Polineni, V.K.3    Essner, A.4    Stark, C.5    Dumbleton, J.H.6
  • 23
    • 0033492096 scopus 로고    scopus 로고
    • Suitability and limitations of carbon fiber reinforced PEEK composites as bearing surfaces for total joint replacements
    • A. Wang, R. Lin, C. Stark and J.H. Dumbleton, Suitability and limitations of carbon fiber reinforced PEEK composites as bearing surfaces for total joint replacements, Wear 225-229 (1999), 724-727.
    • (1999) Wear , vol.225-229 , pp. 724-727
    • Wang, A.1    Lin, R.2    Stark, C.3    Dumbleton, J.H.4
  • 24
    • 0036117407 scopus 로고    scopus 로고
    • A test procedure for artificial finger joints
    • T.J. Joyce and A. Unsworth, A test procedure for artificial finger joints, Engineering in Medicine 216 (2002), 105-110.
    • (2002) Engineering in Medicine , vol.216 , pp. 105-110
    • Joyce, T.J.1    Unsworth, A.2
  • 25
    • 0344944165 scopus 로고    scopus 로고
    • Personal view. Snapping the fingers
    • T.J. Joyce, Personal view. Snapping the fingers, Journal of Hand Surgery 26B (2003), 566-567.
    • (2003) Journal of Hand Surgery , vol.26 B , pp. 566-567
    • Joyce, T.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.