메뉴 건너뛰기




Volumn 115, Issue 1-4, 2005, Pages 345-349

A computer program for the deconvolution of thermoluminescence glow curves

Author keywords

[No Author keywords available]

Indexed keywords

LITHIUM FLUORIDE; MAGNESIUM; TITANIUM;

EID: 30844471966     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci073     Document Type: Article
Times cited : (140)

References (9)
  • 2
    • 0029019898 scopus 로고
    • Computerised glow curve deconvolution: Application to thermoluminescence dosimetry
    • Horowitz, Y. S. and Yossian, D. Computerised glow curve deconvolution: application to thermoluminescence dosimetry. Radiat. Prot. Dosim. 60, 1-114 (1995).
    • (1995) Radiat. Prot. Dosim. , vol.60 , pp. 1-114
    • Horowitz, Y.S.1    Yossian, D.2
  • 3
    • 0002463453 scopus 로고
    • Recent developments in thermoluminescence kinetics
    • Levy, P. W. Recent developments in thermoluminescence kinetics. Nucl. Tracks Meas. 10, 547 (1985).
    • (1985) Nucl. Tracks Meas. , vol.10 , pp. 547
    • Levy, P.W.1
  • 4
    • 30844441660 scopus 로고    scopus 로고
    • A study on the development of highly sensitive LiF, Mg, Cu, Na, Si thermoluminescent detector and its physical and dosimetric characteristics
    • Gyeongsang National University, Ph.D. Thesis
    • Lee, J. I. A study on the development of highly sensitive LiF, Mg, Cu, Na, Si thermoluminescent detector and its physical and dosimetric characteristics, Gyeongsang National University, Ph.D. Thesis, 14 (2003).
    • (2003) , pp. 14
    • Lee, J.I.1
  • 5
    • 36149023643 scopus 로고
    • Evaluation of thermal activation energies from glow curves
    • Halperin, A. and Braner, A. A. Evaluation of thermal activation energies from glow curves. Phys. Rev. 117, 408 (1960).
    • (1960) Phys. Rev. , vol.117 , pp. 408
    • Halperin, A.1    Braner, A.A.2
  • 7
    • 0013358463 scopus 로고
    • Computerised glow curve deconvolution applied to the analysis of the kinetics of peak 5 in LiF: Mg, Ti(TLD-100)
    • Horowitz, Y. S. and Yossian, D. Computerised glow curve deconvolution applied to the analysis of the kinetics of peak 5 in LiF: Mg, Ti(TLD-100). J. Phys. D Appl. Phys. 28, 1495-1508 (1994).
    • (1994) J. Phys. D Appl. Phys. , vol.28 , pp. 1495-1508
    • Horowitz, Y.S.1    Yossian, D.2
  • 8
    • 0000572932 scopus 로고
    • IFOM, a formula for universal assessment of goodness-of-fit of gamma ray spectra
    • Misra, S. K. and Eddy, N. W. IFOM, a formula for universal assessment of goodness-of-fit of gamma ray spectra. Nucl. Instrum. Methods 166, 537-540 (1979).
    • (1979) Nucl. Instrum. Methods , vol.166 , pp. 537-540
    • Misra, S.K.1    Eddy, N.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.