메뉴 건너뛰기




Volumn 46, Issue 8, 2005, Pages 810-814

FFT analysis of the X-ray tube voltage waveforms of high-frequency generators for radiographic systems

Author keywords

Fast Fourier transformation (FFT); High frequency X ray generator; kVp; QA; Tube voltage waveform; X ray tube voltage

Indexed keywords

FAST FOURIER TRANSFORMS; FEEDBACK; PERFORMANCE; QUALITY ASSURANCE; RADIOGRAPHY;

EID: 30844454216     PISSN: 02841851     EISSN: 16000455     Source Type: Journal    
DOI: 10.1080/02841850500335069     Document Type: Article
Times cited : (3)

References (12)
  • 1
    • 0035403407 scopus 로고    scopus 로고
    • Malpractice issues in radiology. Radiation-induced skin injuries and fluoroscopy
    • Berlin L. Malpractice issues in radiology. Radiation-induced skin injuries and fluoroscopy. Am J Roentgenol 2001;177:21-5.
    • (2001) Am J Roentgenol , vol.177 , pp. 21-25
    • Berlin, L.1
  • 2
    • 0034150004 scopus 로고    scopus 로고
    • Relationship between the pixel value in digital subtraction angiography and iodine concentration: Study in high iodine concentration with original phantom
    • Chida K, Sai M, Saito H, Takase K, Zuguchi M, Sasaki M, et al. Relationship between the pixel value in digital subtraction angiography and iodine concentration: study in high iodine concentration with original phantom. Tohoku J Exp Med 2000;190:169-76.
    • (2000) Tohoku J Exp Med , vol.190 , pp. 169-176
    • Chida, K.1    Sai, M.2    Saito, H.3    Takase, K.4    Zuguchi, M.5    Sasaki, M.6
  • 3
    • 7944234005 scopus 로고    scopus 로고
    • Does digital acquisition reduce patients' skin dose in cardiac interventional procedures? An experimental study
    • Chida K, Saito H, Zuguchi M, Shirotori K, Kumagai S, Nakayama H, et al. Does digital acquisition reduce patients' skin dose in cardiac interventional procedures? An experimental study. Am J Roentgenol, 2004; 183:1111-14.
    • (2004) Am J Roentgenol , vol.183 , pp. 1111-1114
    • Chida, K.1    Saito, H.2    Zuguchi, M.3    Shirotori, K.4    Kumagai, S.5    Nakayama, H.6
  • 4
    • 33645800787 scopus 로고    scopus 로고
    • Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures
    • in press
    • Chida K, Saito H, Otani H, Zuguchi M, Kohzuki M, Takahashi S. et al. Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. Am J Roentgenol 2006 (in press).
    • (2006) Am J Roentgenol
    • Chida, K.1    Saito, H.2    Otani, H.3    Zuguchi, M.4    Kohzuki, M.5    Takahashi, S.6
  • 5
    • 0034146244 scopus 로고    scopus 로고
    • Patient radiation exposure during coronary angiography and intervention
    • Fransson S-G, Persliden J. Patient radiation exposure during coronary angiography and intervention. Acta Radiol 2000;41:142-4.
    • (2000) Acta Radiol , vol.41 , pp. 142-144
    • Fransson, S.-G.1    Persliden, J.2
  • 7
    • 33746115896 scopus 로고    scopus 로고
    • Recommended standards for the routine performance testing of diagnostic X-ray imaging systems
    • York
    • Institute of Physics and Engineering in Mecicine. Recommended standards for the routine performance testing of diagnostic X-ray imaging systems, IPEM report no. 77, York. 2000.
    • (2000) IPEM Report No. 77 , vol.77
  • 8
    • 0034979308 scopus 로고    scopus 로고
    • Skin injuries from fluoroscopically guided procedures. Part 2: Review of 73 cases and recommendations for minimizing dose delivered to patient
    • Koenig TR, Mettler FA, Wagner LK. Skin injuries from fluoroscopically guided procedures. Part 2: Review of 73 cases and recommendations for minimizing dose delivered to patient. Am J Roentgenol 2001;177:13-20.
    • (2001) Am J Roentgenol , vol.177 , pp. 13-20
    • Koenig, T.R.1    Mettler, F.A.2    Wagner, L.K.3
  • 9
    • 0031261472 scopus 로고    scopus 로고
    • The AAPM/RSNA physics tutorial for residents. X-ray generators
    • Seibert JA. The AAPM/RSNA physics tutorial for residents. X-ray generators. Radiographics, 1997; 17:1533-57.
    • (1997) Radiographics , vol.17 , pp. 1533-1557
    • Seibert, J.A.1
  • 10
    • 0036173857 scopus 로고    scopus 로고
    • High frequency X-ray generator basics
    • Sobol WT. High frequency X-ray generator basics. Med Phys 2002;29:132-44.
    • (2002) Med Phys , vol.29 , pp. 132-144
    • Sobol, W.T.1
  • 11
    • 0003203252 scopus 로고    scopus 로고
    • Radiationinduced skin injury after percutaneous transluminal coronary angioplasty. Case report
    • Søvik E, Kløw NE, Hellesnes J, Lykke J. Radiationinduced skin injury after percutaneous transluminal coronary angioplasty. Case report. Acta Radiol 1996;37:305-6.
    • (1996) Acta Radiol , vol.37 , pp. 305-306
    • Søvik, E.1    Kløw, N.E.2    Hellesnes, J.3    Lykke, J.4
  • 12
    • 2942642520 scopus 로고    scopus 로고
    • Radiation injury from a fluoroscopic procedure
    • Wong L, Rehm J. Radiation injury from a fluoroscopic procedure. N Engl J Med 2004;350:e23.
    • (2004) N Engl J Med , vol.350
    • Wong, L.1    Rehm, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.