메뉴 건너뛰기




Volumn 116, Issue 1-4, 2005, Pages 160-164

New method of voxel phantom creation: Application for whole-body counting calibration and perspectives in individual internal dose assessment

Author keywords

[No Author keywords available]

Indexed keywords

RADIOISOTOPE;

EID: 30844452477     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci055     Document Type: Article
Times cited : (15)

References (10)
  • 1
    • 0003855286 scopus 로고
    • Phantoms and computational models in therapy, diagnosis and protection
    • International Commission on Radiation Units and Measurements (Bethesda, MD: ICRU)
    • International Commission on Radiation Units and Measurements. Phantoms and computational models in therapy, diagnosis and protection. ICRU Report 48 (Bethesda, MD: ICRU) (1992).
    • (1992) ICRU Report 48
  • 2
    • 0033818054 scopus 로고    scopus 로고
    • Metrological parameters of the unified calibration whole-body phantom with gamma-emitting radionuclides
    • Kovtun, A. N., Firsanov, V. B., Fominykh, V. I. and Isaakyan, G. A. Metrological parameters of the unified calibration whole-body phantom with gamma-emitting radionuclides. Radiat. Prot. Dosim. 89(3-4), 239-242 (2000).
    • (2000) Radiat. Prot. Dosim. , vol.89 , Issue.3-4 , pp. 239-242
    • Kovtun, A.N.1    Firsanov, V.B.2    Fominykh, V.I.3    Isaakyan, G.A.4
  • 3
    • 0036069138 scopus 로고    scopus 로고
    • A new graphical user interface for fast construction of computation phantoms and MCNP calculations: Application to calibration of in vivo measurement system
    • Borissov, N., Franck, D., de Carlan, L. and Laval, L. A new graphical user interface for fast construction of computation phantoms and MCNP calculations: Application to calibration of in vivo measurement system. Health Phys. 83(2), 272-279 (2002).
    • (2002) Health Phys. , vol.83 , Issue.2 , pp. 272-279
    • Borissov, N.1    Franck, D.2    de Carlan, L.3    Laval, L.4
  • 5
    • 0003395844 scopus 로고    scopus 로고
    • MCNP™ - A general Monte Carlo N-particle transport code, version 4c
    • (Los Alamos National Laboratory, Los Alamos, NM)
    • Briesmeister, J. F. MCNP™ - a general Monte Carlo N-particle transport code, version 4c. LANL Memorandum, LANL Report LA-13709-M (Los Alamos National Laboratory, Los Alamos, NM) (2000).
    • (2000) LANL Memorandum, LANL Report LA-13709-M
    • Briesmeister, J.F.1
  • 6
    • 33645202287 scopus 로고    scopus 로고
    • Current developments at IRSN on computational tools dedicated to dose assessment for both internal and external exposure
    • Invited paper
    • Aubineau-Lanièce, I., de Carlan, L., Clairand, I., Lemosquet, A., Chiavassa, S., Pierrat, N. and Franck, D. Current developments at IRSN on computational tools dedicated to dose assessment for both internal and external exposure. ICRS-RPS 2004, Invited paper.
    • (2004) ICRS-RPS
    • Aubineau-Lanièce, I.1    de Carlan, L.2    Clairand, I.3    Lemosquet, A.4    Chiavassa, S.5    Pierrat, N.6    Franck, D.7
  • 7
    • 0003682469 scopus 로고
    • Tissue substitutes in radiation dosimetry and measurements
    • International Commission on Radiation Units and Measurements (Bethesda, MD: ICRU)
    • International Commission on Radiation Units and Measurements. Tissue substitutes in radiation dosimetry and measurements. ICRU Report 44 (Bethesda, MD: ICRU) (1989).
    • (1989) ICRU Report 44
  • 8
    • 31544460057 scopus 로고    scopus 로고
    • Calibration of a whole body counting system with a new type of anthropomorphic phantom
    • (2003-2)
    • Dousse-Dubiau, C., Franck, D., de Carlan, L. and Rouit E. Calibration of a whole body counting system with a new type of anthropomorphic phantom. Bull. Bureau Natl. Métrol. 123(2003-2), 49-53 (2003).
    • (2003) Bull. Bureau Natl. Métrol. , vol.123 , pp. 49-53
    • Dousse-Dubiau, C.1    Franck, D.2    de Carlan, L.3    Rouit, E.4
  • 9
    • 0037431977 scopus 로고    scopus 로고
    • Accounting for incomplete charge collection in Monte Carlo simulations of the efficiency of well-type Ge-detectors
    • Hernandez, F. and El-Daoushy, F. Accounting for incomplete charge collection in Monte Carlo simulations of the efficiency of well-type Ge-detectors. Nucl. Instrum. Methods Phys. Res. A 498, 340-351 (2003).
    • (2003) Nucl. Instrum. Methods Phys. Res. A , vol.498 , pp. 340-351
    • Hernandez, F.1    El-Daoushy, F.2
  • 10
    • 0141807509 scopus 로고    scopus 로고
    • Evaluation of scatter contribution from shielding materials used in scatter measurements for calibration range characterization
    • Friedman, R. J., Reichard, M. C., Blue, T. E. and Brown, A. S. Evaluation of scatter contribution from shielding materials used in scatter measurements for calibration range characterization. Health Phys. 76, 288-299 (2001).
    • (2001) Health Phys. , vol.76 , pp. 288-299
    • Friedman, R.J.1    Reichard, M.C.2    Blue, T.E.3    Brown, A.S.4