메뉴 건너뛰기




Volumn 20, Issue 6, 2005, Pages 411-413

Attempted cleaning of bloodstains and its effect on the forensic luminol test

Author keywords

Bloodstains; Chemiluminescence; Forensic science; Luminol; Presumptive blood testing

Indexed keywords

BLEACHING; BLOOD; CLEANING; FORENSIC SCIENCE;

EID: 30844442826     PISSN: 15227235     EISSN: 15227243     Source Type: Journal    
DOI: 10.1002/bio.865     Document Type: Article
Times cited : (36)

References (6)
  • 1
    • 0001943106 scopus 로고
    • Simplified preliminary blood testing: An improved technique and a comparative study of methods
    • Grodsky M, Wright K, Kirk PL. Simplified preliminary blood testing: an improved technique and a comparative study of methods. J. Crimin. Law Criminol. Police Sci. 1951; 42: 95-104.
    • (1951) J. Crimin. Law Criminol. Police Sci. , vol.42 , pp. 95-104
    • Grodsky, M.1    Wright, K.2    Kirk, P.L.3
  • 2
    • 0012606253 scopus 로고
    • Detection of blood by means of chemiluminescence
    • Proescher F, Moody AM. Detection of blood by means of chemiluminescence. J. Lab. Clin. Med. 1939; 24: 1183-1189.
    • (1939) J. Lab. Clin. Med. , vol.24 , pp. 1183-1189
    • Proescher, F.1    Moody, A.M.2
  • 3
    • 0035348945 scopus 로고    scopus 로고
    • Increasing the specificity of the forensic luminol test for blood
    • Quickenden TI, Cooper PD. Increasing the specificity of the forensic luminol test for blood. Luminescence 2001; 16: 251-253.
    • (2001) Luminescence , vol.16 , pp. 251-253
    • Quickenden, T.I.1    Cooper, P.D.2
  • 4
    • 0035403528 scopus 로고    scopus 로고
    • A study of common interferences with the forensic luminol test for blood
    • Quickenden TI, Creamer JI. A study of common interferences with the forensic luminol test for blood. Luminescence 2001; 16: 295-298.
    • (2001) Luminescence , vol.16 , pp. 295-298
    • Quickenden, T.I.1    Creamer, J.I.2
  • 5
    • 2442483915 scopus 로고    scopus 로고
    • A comprehensive experimental study of industrial, domestic and environmental interferences with the forensic luminol test for blood
    • Creamer JI, Quickenden TI, Apanah MV, Kerr KA, Robertson P. A comprehensive experimental study of industrial, domestic and environmental interferences with the forensic luminol test for blood. Luminescence 2003; 18: 193-198.
    • (2003) Luminescence , vol.18 , pp. 193-198
    • Creamer, J.I.1    Quickenden, T.I.2    Apanah, M.V.3    Kerr, K.A.4    Robertson, P.5