메뉴 건너뛰기




Volumn 5916, Issue , 2005, Pages 1-12

An unsupervised approach for measuring myocardial perfusion in MR image sequences

Author keywords

Cardiac perfusion MRI; Model based segmentation and tracking; Morphological segmentation; Non rigid registration; Statistical active contour

Indexed keywords

CARDIOVASCULAR SURGERY; IMAGE ANALYSIS; IMAGE SEGMENTATION; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; PROBLEM SOLVING;

EID: 30844440285     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.621358     Document Type: Conference Paper
Times cited : (7)

References (17)
  • 2
    • 0025269066 scopus 로고
    • First-pass cardiac perfusion: Evaluation with ultrafast MR imaging
    • D.J. Atkinson, D. Burstein, R.R. Edelman, "First-pass cardiac perfusion: Evaluation with ultrafast MR imaging." Radiology 174(3), pp. 757-762, 1990.
    • (1990) Radiology , vol.174 , Issue.3 , pp. 757-762
    • Atkinson, D.J.1    Burstein, D.2    Edelman, R.R.3
  • 4
    • 0034724169 scopus 로고    scopus 로고
    • Non-invasive detection of myocardial ischemia from perfusion reserve based on cardiovascular Magnetic Resonance
    • N. Al-Saadi, E. Nagel, M. Gross, A. Bornstedt, B. Schnackenburg, C. Klein, H. Oswald, E. Fleck, "Non-invasive detection of myocardial ischemia from perfusion reserve based on cardiovascular Magnetic Resonance," Circulation 101(12), pp. 1379-1383, 2000.
    • (2000) Circulation , vol.101 , Issue.12 , pp. 1379-1383
    • Al-Saadi, N.1    Nagel, E.2    Gross, M.3    Bornstedt, A.4    Schnackenburg, B.5    Klein, C.6    Oswald, H.7    Fleck, E.8
  • 6
    • 3342886330 scopus 로고    scopus 로고
    • Realignment of myocardial first-pass MR perfusion imaging using an automatic detection of the heart-lung interface
    • M. Jerosch-Herold, R.T. Seethamraju, C.M. Swingen, N. Wilke, A.E. Stillman, "Realignment of myocardial first-pass MR perfusion imaging using an automatic detection of the heart-lung interface," Magnetic Resonance Imaging 19(8), pp. 1001-1009, 2004.
    • (2004) Magnetic Resonance Imaging , vol.19 , Issue.8 , pp. 1001-1009
    • Jerosch-Herold, M.1    Seethamraju, R.T.2    Swingen, C.M.3    Wilke, N.4    Stillman, A.E.5
  • 7
    • 20444449819 scopus 로고    scopus 로고
    • Unsupervised motion-compensation of multi-slice cardiac perfusion MRI
    • M.N. Stegmann, H. Olafsdottir, H.B. Larsson, "Unsupervised motion-compensation of multi-slice cardiac perfusion MRI," Medical Image Analysis 9(4), pp. 394-410, 2005.
    • (2005) Medical Image Analysis , vol.9 , Issue.4 , pp. 394-410
    • Stegmann, M.N.1    Olafsdottir, H.2    Larsson, H.B.3
  • 8
    • 0037192118 scopus 로고    scopus 로고
    • Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart
    • M.D. Cerqueira, N.J. Weissman, C. Dilsizian, A.K. Jacobs, S. Kaul, W.K. Laskey et al., "Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart," Circulation 105(4), pp. 539-542, 2002.
    • (2002) Circulation , vol.105 , Issue.4 , pp. 539-542
    • Cerqueira, M.D.1    Weissman, N.J.2    Dilsizian, C.3    Jacobs, A.K.4    Kaul, S.5    Laskey, W.K.6
  • 10
    • 0003386605 scopus 로고
    • On a distance function approach for gray-level mathematical morphology
    • E.R. Dougherty, ed., Marcel Dekker, New York
    • F. Prêteux, "On a distance function approach for gray-level mathematical morphology," in Mathematical Morphology in Image Processing, E.R. Dougherty, ed., Marcel Dekker, New York, 1992.
    • (1992) Mathematical Morphology in Image Processing
    • Prêteux, F.1
  • 11
    • 9244243057 scopus 로고    scopus 로고
    • Pulmonary airways: 3-D reconstruction from multislice CT and clinical investigation
    • C. Fetita, F. Prêteux, C. Beigelman, P. Grenier, "Pulmonary airways: 3-D reconstruction from multislice CT and clinical investigation," IEEE Transactions on Medical Imaging 23(11), pp. 1353-1364, 2004.
    • (2004) IEEE Transactions on Medical Imaging , vol.23 , Issue.11 , pp. 1353-1364
    • Fetita, C.1    Prêteux, F.2    Beigelman, C.3    Grenier, P.4
  • 14
    • 30844450421 scopus 로고    scopus 로고
    • Region-driven statistical non rigid registration. Application to model-based segmentation and tracking of the heart in perfusion MRI
    • August
    • N. Rougon, A. Discher, F. Prêteux, "Region-driven statistical non rigid registration. Application to model-based segmentation and tracking of the heart in perfusion MRI," in These proceedings, August 2005.
    • (2005) These Proceedings
    • Rougon, N.1    Discher, A.2    Prêteux, F.3
  • 15
    • 20444450557 scopus 로고    scopus 로고
    • A non-rigid registration approach for quantifying myocardial contraction in tagged MRI using generalized information measures
    • N. Rougon, C. Petitjean, F. Prêteux, P. Cluzel, P. Grenier, "A non-rigid registration approach for quantifying myocardial contraction in tagged MRI using generalized information measures," Medical Image Analysis 9(4), pp. 353-375, 2005.
    • (2005) Medical Image Analysis , vol.9 , Issue.4 , pp. 353-375
    • Rougon, N.1    Petitjean, C.2    Prêteux, F.3    Cluzel, P.4    Grenier, P.5
  • 16
    • 0026074874 scopus 로고
    • First-pass nuclear magnetic resonance imaging studies using gadolinium-DTPA in patients with coronary artery disease
    • W.J. Manning, D.J. Atkinson, W. Grossman, S. Paulin, R.R. Edelman, "First-pass nuclear magnetic resonance imaging studies using gadolinium-DTPA in patients with coronary artery disease," Journal of American College of Cardiology 18(4), pp. 959-965, 1991.
    • (1991) Journal of American College of Cardiology , vol.18 , Issue.4 , pp. 959-965
    • Manning, W.J.1    Atkinson, D.J.2    Grossman, W.3    Paulin, S.4    Edelman, R.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.