메뉴 건너뛰기




Volumn 28, Issue 1 SPEC. ISS., 2006, Pages 90-98

Finite element analysis of the lumbar spine with a new cage using a topology optimization method

Author keywords

Biomechanics; Cage; Finite element method

Indexed keywords

BIOMECHANICS; COMPUTER SOFTWARE; OPTIMIZATION; PRODUCT DESIGN; TOPOLOGY;

EID: 30844437040     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2005.03.007     Document Type: Conference Paper
Times cited : (157)

References (30)
  • 1
    • 0023802243 scopus 로고
    • Arthrodesis by the distraction-compression method using a stainless steel implant
    • G.W. Bagby Arthrodesis by the distraction-compression method using a stainless steel implant Orthopedics 11 1988 931 934
    • (1988) Orthopedics , vol.11 , pp. 931-934
    • Bagby, G.W.1
  • 2
    • 0033022140 scopus 로고    scopus 로고
    • Interbody fusion cages in reconstructive operations on the spine
    • P.C. McAfee Interbody fusion cages in reconstructive operations on the spine J Bone Joint Surg [Am] 81-A 6 1999 859 880
    • (1999) J Bone Joint Surg [Am] , vol.81 A , Issue.6 , pp. 859-880
    • McAfee, P.C.1
  • 3
    • 0036309154 scopus 로고    scopus 로고
    • Cervical cages fusion with 5 different implants: 250 cases
    • G. Matge Cervical cages fusion with 5 different implants: 250 cases Acta Neurochir 144 6 2002 539 549
    • (2002) Acta Neurochir , vol.144 , Issue.6 , pp. 539-549
    • Matge, G.1
  • 4
    • 0028363157 scopus 로고
    • Interbody lumbar fusion using a carbon fiber cage implant versus allograft bone. An investigational study in the Spanish goat
    • J.W. Brantigan, P.C. McAfee, B.W. Cunningham, H. Wang, and C.M. Orbegoso Interbody lumbar fusion using a carbon fiber cage implant versus allograft bone. An investigational study in the Spanish goat Spine 19 13 1994 1436 1444
    • (1994) Spine , vol.19 , Issue.13 , pp. 1436-1444
    • Brantigan, J.W.1    McAfee, P.C.2    Cunningham, B.W.3    Wang, H.4    Orbegoso, C.M.5
  • 5
    • 0030910461 scopus 로고    scopus 로고
    • Threaded titanium cages for lumbar interbody fusions
    • C.D. Ray Threaded titanium cages for lumbar interbody fusions Spine 22 6 1997 667 679
    • (1997) Spine , vol.22 , Issue.6 , pp. 667-679
    • Ray, C.D.1
  • 6
    • 0027423357 scopus 로고
    • A carbon fiber implant to aid interbody lumbar fusion: Two-year clinical results in the first 26 patients
    • J.W. Brantigan, and A.D. Steffee A carbon fiber implant to aid interbody lumbar fusion: two-year clinical results in the first 26 patients Spine 18 14 1993 2106 2117
    • (1993) Spine , vol.18 , Issue.14 , pp. 2106-2117
    • Brantigan, J.W.1    Steffee, A.D.2
  • 7
    • 0034665560 scopus 로고    scopus 로고
    • Analysis of titanium mesh cages in adults with minimum two-year follow-up
    • K.R. Eck, K.H. Bridwell, F.F. Ungacta, M.A. Lapp, L.G. Lenke, and K.D. Riew Analysis of titanium mesh cages in adults with minimum two-year follow-up Spine 25 18 2000 2407 2415
    • (2000) Spine , vol.25 , Issue.18 , pp. 2407-2415
    • Eck, K.R.1    Bridwell, K.H.2    Ungacta, F.F.3    Lapp, M.A.4    Lenke, L.G.5    Riew, K.D.6
  • 9
    • 0034667346 scopus 로고    scopus 로고
    • Four-year follow-up results of lumbar spine arthrodesis using the Bagby and Kuslich lumbar fusion cages
    • S.D. Kuslich, G. Danielson, J.D. Dowdle, J. Sherman, B. Fredrickson, and H. Yuan Four-year follow-up results of lumbar spine arthrodesis using the Bagby and Kuslich lumbar fusion cages Spine 25 20 2000 2656 2662
    • (2000) Spine , vol.25 , Issue.20 , pp. 2656-2662
    • Kuslich, S.D.1    Danielson, G.2    Dowdle, J.D.3    Sherman, J.4    Fredrickson, B.5    Yuan, H.6
  • 11
    • 0035257041 scopus 로고    scopus 로고
    • The influence of cancellous bone density on load shearing in human lumbar spine: A compression between an intact and surgically altered motion segment
    • T. Pitzen, F.H. Geisler, D. Matthis, H. Muller-Storz, K. Pedersen, and W.I. Steudel The influence of cancellous bone density on load shearing in human lumbar spine: a compression between an intact and surgically altered motion segment Eur Spine J 10 2001 23 29
    • (2001) Eur Spine J , vol.10 , pp. 23-29
    • Pitzen, T.1    Geisler, F.H.2    Matthis, D.3    Muller-Storz, H.4    Pedersen, K.5    Steudel, W.I.6
  • 12
    • 0035399368 scopus 로고    scopus 로고
    • Prediction of mechanical behaviors at interfaces between bone and two interbody cages of lumbar spine segments
    • Y. Kim Prediction of mechanical behaviors at interfaces between bone and two interbody cages of lumbar spine segments Spine 26 13 2001 1437 1442
    • (2001) Spine , vol.26 , Issue.13 , pp. 1437-1442
    • Kim, Y.1
  • 13
    • 0036192019 scopus 로고    scopus 로고
    • The effect of posterior instrumentation following PLIF with BAK cages is most pronounced in weak bone
    • T. Pitzen, D. Matthis, and W.I. Steudel The effect of posterior instrumentation following PLIF with BAK cages is most pronounced in weak bone Acta Neurochir (Wien) 144 2 2002 121 128
    • (2002) Acta Neurochir (Wien) , vol.144 , Issue.2 , pp. 121-128
    • Pitzen, T.1    Matthis, D.2    Steudel, W.I.3
  • 14
    • 0036791682 scopus 로고    scopus 로고
    • Load transfer mechanisms in cylindrical interdody cages constructs
    • W.J. Palm, W.S. Rosenberg, and T.M. Keaveny Load transfer mechanisms in cylindrical interdody cages constructs Spine 27 19 2002 2101 2107
    • (2002) Spine , vol.27 , Issue.19 , pp. 2101-2107
    • Palm, W.J.1    Rosenberg, W.S.2    Keaveny, T.M.3
  • 15
    • 0041736360 scopus 로고    scopus 로고
    • Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: Finite element analysis
    • A. Polikeit, S.J. Ferguson, L.P. Nolte, and T.E. Orr Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis Eur Spine J 12 4 2002 413 420
    • (2002) Eur Spine J , vol.12 , Issue.4 , pp. 413-420
    • Polikeit, A.1    Ferguson, S.J.2    Nolte, L.P.3    Orr, T.E.4
  • 16
    • 0037403146 scopus 로고    scopus 로고
    • Stress analysis of interbody fusion - Finite element modeling of intervertebral implant and vertebral body
    • C. Adam, M. Pearcy, and P. McCombe Stress analysis of interbody fusion - finite element modeling of intervertebral implant and vertebral body Clin Biomech 18 2003 265 272
    • (2003) Clin Biomech , vol.18 , pp. 265-272
    • Adam, C.1    Pearcy, M.2    McCombe, P.3
  • 17
    • 0028953442 scopus 로고
    • Interlaminar shear stresses and laminae separation in a disc. Finite element analysis of the L3-L4 motion segment subjected to axial compressive loads
    • V.K. Goel, B.T. Monroe, L.G. Gilbertson, and P. Brinckmann Interlaminar shear stresses and laminae separation in a disc. Finite element analysis of the L3-L4 motion segment subjected to axial compressive loads Spine 20 6 1995 689 698
    • (1995) Spine , vol.20 , Issue.6 , pp. 689-698
    • Goel, V.K.1    Monroe, B.T.2    Gilbertson, L.G.3    Brinckmann, P.4
  • 18
    • 0016881773 scopus 로고
    • Mechanical behavior of the human annulus fibrosus
    • H.C. Wu, and R.F. Yao Mechanical behavior of the human annulus fibrosus J Biomech 9 1967 1 7
    • (1967) J Biomech , Issue.9 , pp. 1-7
    • Wu, H.C.1    Yao, R.F.2
  • 21
    • 0034802078 scopus 로고    scopus 로고
    • Stress analysis of the disc adjacent fusion in lumbar spine
    • C.S. Chen, C.K. Cheng, C.L. Liu, and W.H. Lo Stress analysis of the disc adjacent fusion in lumbar spine Med Eng Phys 23 2001 483 491
    • (2001) Med Eng Phys , vol.23 , pp. 483-491
    • Chen, C.S.1    Cheng, C.K.2    Liu, C.L.3    Lo, W.H.4
  • 22
    • 0036171846 scopus 로고    scopus 로고
    • A biomechanical comparison of posterolateral fusion and posterior fusion in the lumbar spine
    • C.S. Chen, C.K. Cheng, and C.L. Liu A biomechanical comparison of posterolateral fusion and posterior fusion in the lumbar spine J Spinal Disord Tech 15 1 2002 53 63
    • (2002) J Spinal Disord Tech , vol.15 , Issue.1 , pp. 53-63
    • Chen, C.S.1    Cheng, C.K.2    Liu, C.L.3
  • 23
    • 13744256317 scopus 로고    scopus 로고
    • Biomechanical analysis of the disc adjacent to posterolateral fusion with laminectomy in lumbar spine
    • C.S. Chen, C.K. Feng, C.K. Cheng, M.J. Tzeng, C.L. Liu, and W.J. Chen Biomechanical analysis of the disc adjacent to posterolateral fusion with laminectomy in lumbar spine J Spinal Disorder Tech 18 1 2005 58 65
    • (2005) J Spinal Disorder Tech , vol.18 , Issue.1 , pp. 58-65
    • Chen, C.S.1    Feng, C.K.2    Cheng, C.K.3    Tzeng, M.J.4    Liu, C.L.5    Chen, W.J.6
  • 24
    • 30844471199 scopus 로고    scopus 로고
    • Can autograft stiffen interbody fusion cages?
    • Orthopaedics Research Society, San Francisco, CA
    • M. Svehla, P. McCoombe, R. Stanford, and W. Walsh Can autograft stiffen interbody fusion cages? 47th Annual Meeting Orthopaedics Research Society, San Francisco, CA 2001
    • (2001) 47th Annual Meeting
    • Svehla, M.1    McCoombe, P.2    Stanford, R.3    Walsh, W.4
  • 26
    • 0024819818 scopus 로고
    • Three-dimension movement of the whole lumbar spine and lumbosacral joint
    • I. Yamamoto, M.M. Panjabi, T. Crisco, and T. Oxland Three-dimension movement of the whole lumbar spine and lumbosacral joint Spine 14 11 1989 1256 1260
    • (1989) Spine , vol.14 , Issue.11 , pp. 1256-1260
    • Yamamoto, I.1    Panjabi, M.M.2    Crisco, T.3    Oxland, T.4
  • 27
    • 30844446089 scopus 로고    scopus 로고
    • Primary stability of dorsal lumbar spondylodesis and vertebral body replacement surgery - Comparison of different vertebral body replacement cages in-vitro
    • Orthopaedics Research Society, San Francisco, CA
    • M.M. Morlock, J. Strandborg, R. Nassutt, K. Sellenschloh, and C. Eggers Primary stability of dorsal lumbar spondylodesis and vertebral body replacement surgery - comparison of different vertebral body replacement cages in-vitro 47th Annual Meeting Orthopaedics Research Society, San Francisco, CA 2001
    • (2001) 47th Annual Meeting
    • Morlock, M.M.1    Strandborg, J.2    Nassutt, R.3    Sellenschloh, K.4    Eggers, C.5
  • 28
    • 0028415083 scopus 로고
    • Elastic and viscoelastic properties of trabecular bone by a compression testing approach
    • F. Linde Elastic and viscoelastic properties of trabecular bone by a compression testing approach Dan Med Bull 41 1994 119 138
    • (1994) Dan Med Bull , vol.41 , pp. 119-138
    • Linde, F.1
  • 29
    • 0345874545 scopus 로고    scopus 로고
    • Bone ingrowth characteristics of porous tantalum and carbon fiber interbody device: An experimental study in pigs
    • X. Zou, H. Li, M. Bunger, N. Egund, M. Lind, and C. Bunger Bone ingrowth characteristics of porous tantalum and carbon fiber interbody device: an experimental study in pigs Spine J 4 2004 99 105
    • (2004) Spine J , vol.4 , pp. 99-105
    • Zou, X.1    Li, H.2    Bunger, M.3    Egund, N.4    Lind, M.5    Bunger, C.6
  • 30
    • 0004293936 scopus 로고
    • Airforce Materials Laboratory. Metals, Ceramics Information Center
    • Wood RA, Favor BJ. Titanium Alloy Handbook. Airforce Materials Laboratory. Metals, Ceramics Information Center, 1972.
    • (1972) Titanium Alloy Handbook
    • Wood, R.A.1    Favor, B.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.