메뉴 건너뛰기




Volumn 115, Issue 1-4, 2005, Pages 616-622

An approach to 3D dose mapping using gafchromic® film

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BEAM THERAPY; COMPUTER PROGRAM; DATA ANALYSIS; FILM DOSIMETER; MICRODENSITOMETRY; OPTICAL DENSITY; PHANTOM; PROTON THERAPY; RADIATION BEAM; RADIATION DOSE DISTRIBUTION; THREE DIMENSIONAL IMAGING;

EID: 30844433730     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nci255     Document Type: Article
Times cited : (12)

References (15)
  • 1
    • 0001326870 scopus 로고
    • Sensitometry of the response of a new radiochromic film dosimetry to gamma radiation and electron beams
    • McLaughlin, W. L., Yun-Dong, C., Soares, C. G., Miller, A., Van Dyk, G. and Lewis, D. F. Sensitometry of the response of a new radiochromic film dosimetry to gamma radiation and electron beams. Nucl. Instrum. Methods. 302(A), 165-176 (1991).
    • (1991) Nucl. Instrum. Methods. , vol.302 , Issue.A , pp. 165-176
    • McLaughlin, W.L.1    Yun-Dong, C.2    Soares, C.G.3    Miller, A.4    Van Dyk, G.5    Lewis, D.F.6
  • 2
    • 0028218940 scopus 로고
    • The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics
    • McLaughlin, W. L., Soares, C. G., Sayeg, J. A., McCullough, E. C., Kline, R. W., Wu, A. and Maltz, A. H. The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics. Med. Phys. 21(3), 379-388 (1994).
    • (1994) Med. Phys. , vol.21 , Issue.3 , pp. 379-388
    • McLaughlin, W.L.1    Soares, C.G.2    Sayeg, J.A.3    McCullough, E.C.4    Kline, R.W.5    Wu, A.6    Maltz, A.H.7
  • 3
    • 0029890948 scopus 로고    scopus 로고
    • Radiochromic film as a radiotherapy surface-dose detector
    • Butson, M. J., Mathur, J. N. and Metcalfe, P. E. Radiochromic film as a radiotherapy surface-dose detector. Phys. Med. Biol. 41, 1073-1078 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1073-1078
    • Butson, M.J.1    Mathur, J.N.2    Metcalfe, P.E.3
  • 4
    • 0030756665 scopus 로고    scopus 로고
    • Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery
    • Vatnitsky, S. M., Schulte, R. W. M., Galindo, R., Meinass, H. J. and Miller, D. W. Radiochromic film dosimetry for verification of dose distributions delivered with proton-beam radiosurgery. Phys. Med. Biol. 42, 1887-1898 (1997).
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1887-1898
    • Vatnitsky, S.M.1    Schulte, R.W.M.2    Galindo, R.3    Meinass, H.J.4    Miller, D.W.5
  • 5
    • 0031148917 scopus 로고    scopus 로고
    • Radiochromic film dosimetry for clinical proton beams
    • Vatnitsky, S. M. Radiochromic film dosimetry for clinical proton beams. Appl. Radiat. Isot. 48(5), 643-651 (1997).
    • (1997) Appl. Radiat. Isot. , vol.48 , Issue.5 , pp. 643-651
    • Vatnitsky, S.M.1
  • 6
    • 0032726570 scopus 로고    scopus 로고
    • An application of Gafchromic Md-55 film for 67.5 MeV clinical proton beam dosimetry
    • Daftari, I., Castenadas, C., Petti, P. L., Singh, R. P. and Verhey, L. J. An application of Gafchromic Md-55 film for 67.5 MeV clinical proton beam dosimetry. Phys. Med. Biol. 44, 2735-2745 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 2735-2745
    • Daftari, I.1    Castenadas, C.2    Petti, P.L.3    Singh, R.P.4    Verhey, L.J.5
  • 8
    • 30844438533 scopus 로고    scopus 로고
    • Data sheet by the Advanced Materials Group of International Specialty Products (ISP). Available at
    • Data sheet by the Advanced Materials Group of International Specialty Products (ISP). Available at (2004).
    • (2004)
  • 10
    • 0029832035 scopus 로고    scopus 로고
    • Dosimetric characteristics of an improved radiochromic film
    • Meigooni, A. S., Sanders, M. F., Ibbott, G. S. and Szeglin, S. R. Dosimetric characteristics of an improved radiochromic film. Med. Phys. 23, 1883-1888 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1883-1888
    • Meigooni, A.S.1    Sanders, M.F.2    Ibbott, G.S.3    Szeglin, S.R.4
  • 12
    • 0031830064 scopus 로고    scopus 로고
    • Effects of redaout light sources and ambient light on radiochromic film
    • Butson, M., Yu, P. and Metcalfe, P. Effects of redaout light sources and ambient light on radiochromic film. Phys. Med. Biol. 43, 2407-2412 (1998).
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2407-2412
    • Butson, M.1    Yu, P.2    Metcalfe, P.3
  • 13
    • 0027376768 scopus 로고
    • The 62 MeV proton for the treatment of ocular melanoma at Clatterbridge
    • Bonnett, D. E., Kacperek, A., Sheen, M. A., Goodall, R. and Saxton, T. E. The 62 MeV proton for the treatment of ocular melanoma at Clatterbridge: Br. J. Radiol. 66, 907-914 (1993).
    • (1993) Br. J. Radiol. , vol.66 , pp. 907-914
    • Bonnett, D.E.1    Kacperek, A.2    Sheen, M.A.3    Goodall, R.4    Saxton, T.E.5
  • 14
    • 0003691941 scopus 로고    scopus 로고
    • Clinical proton dosimetry - Part I: Beam production, beam delivery and measurement of absorbed dose
    • International Commission on Radiation Units and Measurements. ICRU Report 59 (Bethesda, MD: ICRU)
    • International Commission on Radiation Units and Measurements. Clinical proton dosimetry - part I: Beam production, beam delivery and measurement of absorbed dose. ICRU Report 59 (Bethesda, MD: ICRU) (1998).
    • (1998)
  • 15
    • 30844464145 scopus 로고    scopus 로고
    • Datazione archeologica e dosimetrica non convenzionale mediante cristalli luminescenti e film radiocromici
    • Ph.D. Thesis, Università degli Studi di Catania, Italy (unpublished)
    • Gueli, A. M. Datazione archeologica e dosimetrica non convenzionale mediante cristalli luminescenti e film radiocromici. Ph.D. Thesis, Università degli Studi di Catania, Italy (1998). (unpublished).
    • (1998)
    • Gueli, A.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.