메뉴 건너뛰기




Volumn 23, Issue 1, 2006, Pages 50-59

Fiducial markers for MR histological correlation in ex vivo or short-term in vivo animal experiments: A screening study

Author keywords

Experimental medicine; Fiducial markers; Histology; Image registration; Magnetic resonance imaging

Indexed keywords

ACRYLIC ACID; ACRYLIC PAINT; CYANOACRYLATE; DIMETHYL SULFOXIDE; DYE; ETHIODIZED OIL; GADOLINIUM PENTETATE; GLUE; INDIAN INK; IRIDESCENT BRONZE PAINT; IRIDESCENT STAINLESS STEEL PAINT; LIQUID PAPER; MARKER; PAINT; STAINLESS STEEL; SUPERPARAMAGNETIC IRON OXIDE; UNCLASSIFIED DRUG;

EID: 30744478975     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20466     Document Type: Article
Times cited : (15)

References (34)
  • 1
    • 0026452503 scopus 로고
    • In vivo effects of high-intensity-ultrasound on prostatic adenocarcinoma Dunning R3327
    • Chapelon JY, Margonari J, Vernier F, Gorry F, Ecochard R, Gelet A. In vivo effects of high-intensity-ultrasound on prostatic adenocarcinoma Dunning R3327. Cancer Res 1992;52:6353-6357.
    • (1992) Cancer Res , vol.52 , pp. 6353-6357
    • Chapelon, J.Y.1    Margonari, J.2    Vernier, F.3    Gorry, F.4    Ecochard, R.5    Gelet, A.6
  • 2
    • 0034859810 scopus 로고    scopus 로고
    • Transrectal high intensity focused ultrasound for the treatment of localized prostate cancer: Factors influencing the outcome
    • Gelet A, Chapelon JY, Bouvier R, Rouvière O, Lyonnet D, Dubernard JM. Transrectal high intensity focused ultrasound for the treatment of localized prostate cancer: factors influencing the outcome. Eur Urol 2001;40:124-129.
    • (2001) Eur Urol , vol.40 , pp. 124-129
    • Gelet, A.1    Chapelon, J.Y.2    Bouvier, R.3    Rouvière, O.4    Lyonnet, D.5    Dubernard, J.M.6
  • 3
    • 16844382450 scopus 로고    scopus 로고
    • High-intensity focused ultrasound in the treatment of solid tumours
    • Kennedy JE. High-intensity focused ultrasound in the treatment of solid tumours. Nat Rev Cancer 2005;5:321-327.
    • (2005) Nat Rev Cancer , vol.5 , pp. 321-327
    • Kennedy, J.E.1
  • 6
    • 0026468620 scopus 로고
    • Effects of high-energy focused ultrasound on kidney tissue in the rat and the dog
    • Chapelon JY, Margonari J, Theillère Y, et al. Effects of high-energy focused ultrasound on kidney tissue in the rat and the dog. Eur Urol 1992;22:147-152.
    • (1992) Eur Urol , vol.22 , pp. 147-152
    • Chapelon, J.Y.1    Margonari, J.2    Theillère, Y.3
  • 7
    • 0029888837 scopus 로고    scopus 로고
    • The intensity dependence of the site of maximal energy deposition in focused ultrasound surgery
    • Watkin NA, Ter Haar GR, Rivens I. The intensity dependence of the site of maximal energy deposition in focused ultrasound surgery. Ultrasound Med Biol 1996;22:483-491.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 483-491
    • Watkin, N.A.1    Ter Haar, G.R.2    Rivens, I.3
  • 8
    • 0036199894 scopus 로고    scopus 로고
    • MRI-guided thermal therapy of transplanted tumors in the canine prostate using directional transurethral ultrasound applicator
    • Hazle JD, Diederich CJ, Kangasniemi M, Price RE, Olsson LE, Stafford RJ. MRI-guided thermal therapy of transplanted tumors in the canine prostate using directional transurethral ultrasound applicator. J Magn Reson Imaging 2002;15:409-417.
    • (2002) J Magn Reson Imaging , vol.15 , pp. 409-417
    • Hazle, J.D.1    Diederich, C.J.2    Kangasniemi, M.3    Price, R.E.4    Olsson, L.E.5    Stafford, R.J.6
  • 9
    • 0035172455 scopus 로고    scopus 로고
    • MRI study of immediate cell viability in focused ultrasound lesions in the rabbit brain
    • Chen L, Bouley DM, Harris BT, Butts K. MRI study of immediate cell viability in focused ultrasound lesions in the rabbit brain. J Magn Reson Imaging 2001;13:23-30.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 23-30
    • Chen, L.1    Bouley, D.M.2    Harris, B.T.3    Butts, K.4
  • 10
    • 0038787489 scopus 로고    scopus 로고
    • Three-dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response
    • Breen MS, Lancaster TL, Lazebnik RS, Nour SG, Lewin JS, Wilson DL. Three-dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response. J Magn Reson Imaging 2003;18:90-102.
    • (2003) J Magn Reson Imaging , vol.18 , pp. 90-102
    • Breen, M.S.1    Lancaster, T.L.2    Lazebnik, R.S.3    Nour, S.G.4    Lewin, J.S.5    Wilson, D.L.6
  • 12
    • 10744233036 scopus 로고    scopus 로고
    • A stereotactic method for three-dimensional registration of multi-modality biologic images in animals: NMR, PET, histology and autoradiography
    • Humm JL, Ballon D, Hu YC, et al. A stereotactic method for three-dimensional registration of multi-modality biologic images in animals: NMR, PET, histology and autoradiography. Med Phys 2003;30:2303-2314.
    • (2003) Med Phys , vol.30 , pp. 2303-2314
    • Humm, J.L.1    Ballon, D.2    Hu, Y.C.3
  • 13
    • 0031909919 scopus 로고    scopus 로고
    • MRI of laser-induced interstitial thermal injury in an in vivo animal liver model with histologic correlation
    • Morrison PR, Jolesz FA, Charous D, et al. MRI of laser-induced interstitial thermal injury in an in vivo animal liver model with histologic correlation. J Magn Reson Imaging 1998;8:57-63.
    • (1998) J Magn Reson Imaging , vol.8 , pp. 57-63
    • Morrison, P.R.1    Jolesz, F.A.2    Charous, D.3
  • 14
    • 0034033419 scopus 로고    scopus 로고
    • Safety and efficacy of India Ink and indocyanine green as colonic tattooing agents
    • Price N, Gottfried MR, Clary E, et al. Safety and efficacy of India Ink and indocyanine green as colonic tattooing agents. Gastrointest Endosc 2000;51:438-442.
    • (2000) Gastrointest Endosc , vol.51 , pp. 438-442
    • Price, N.1    Gottfried, M.R.2    Clary, E.3
  • 15
    • 0025276165 scopus 로고
    • Tipp-Ex fluid: Convenient marker for surgical resection margins
    • Harris MD. Tipp-Ex fluid: convenient marker for surgical resection margins. J Clin Pathol 1990;43:346-347.
    • (1990) J Clin Pathol , vol.43 , pp. 346-347
    • Harris, M.D.1
  • 16
    • 0023734910 scopus 로고
    • Marking planes of surgical excision on breast biopsy specimens: Use of artists' pigments suspended in acetone
    • Paterson DA, Davies JD. Marking planes of surgical excision on breast biopsy specimens: use of artists' pigments suspended in acetone. J Clin Pathol 1988;41:1013-1016.
    • (1988) J Clin Pathol , vol.41 , pp. 1013-1016
    • Paterson, D.A.1    Davies, J.D.2
  • 17
    • 0036550334 scopus 로고    scopus 로고
    • 2-Octyl-cyanoacrylate (Dermabond), a new glue for variceal injection therapy: Results of a preliminary animal study
    • Nguyen AJ, Baron TH, Burgart LJ, Leontovich O, Rajan E, Gostout CJ. 2-Octyl-cyanoacrylate (Dermabond), a new glue for variceal injection therapy: results of a preliminary animal study. Gastrointest Endosc 2002;55:572-575.
    • (2002) Gastrointest Endosc , vol.55 , pp. 572-575
    • Nguyen, A.J.1    Baron, T.H.2    Burgart, L.J.3    Leontovich, O.4    Rajan, E.5    Gostout, C.J.6
  • 18
    • 0022358185 scopus 로고
    • Staining procedure to aid in assessment of bucrylate histotoxicity in tissue section
    • Lundie MJ, Ellyatt D, Kaufmann JCE, Vinters HV. Staining procedure to aid in assessment of bucrylate histotoxicity in tissue section. Arch Pathol Lab Med 1985;109:779-781.
    • (1985) Arch Pathol Lab Med , vol.109 , pp. 779-781
    • Lundie, M.J.1    Ellyatt, D.2    Jce, K.3    Vinters, H.V.4
  • 20
    • 0028909481 scopus 로고
    • Occlusion of cerebral arteriovenous malformations with n-butyl cyano-acrylate is permanent
    • Wikholm G. Occlusion of cerebral arteriovenous malformations with n-butyl cyano-acrylate is permanent. AJNR Am J Neuroradiol 1995;16:479-482.
    • (1995) AJNR Am J Neuroradiol , vol.16 , pp. 479-482
    • Wikholm, G.1
  • 22
    • 0036841835 scopus 로고    scopus 로고
    • Tissue response to n-butyl-2-cyanoacrylate after percutaneous injection into cutaneous vascular lesions
    • Canter HI, Vargel I, Mavili M, Gokoz A, Erk Y. Tissue response to n-butyl-2-cyanoacrylate after percutaneous injection into cutaneous vascular lesions. Ann Plast Surg 2002;49:520-526.
    • (2002) Ann Plast Surg , vol.49 , pp. 520-526
    • Canter, H.I.1    Vargel, I.2    Mavili, M.3    Gokoz, A.4    Erk, Y.5
  • 23
    • 0032782296 scopus 로고    scopus 로고
    • Pathology findings with acrylic implants
    • San Millan Ruiz D, Burkhardt K, Jean B, et al. Pathology findings with acrylic implants. Bone 1999;25:85S-90S.
    • (1999) Bone , vol.25
    • San Millan Ruiz, D.1    Burkhardt, K.2    Jean, B.3
  • 24
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: Effects of field-strength, sequence design and magnetic field orientation
    • Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR. Needle localization In MR-guided biopsy and aspiration: effects of field-strength, sequence design and magnetic field orientation. AJR Am J Roentgenol 1996;166:1337-1345.
    • (1996) AJR Am J Roentgenol , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3    Petersilge, C.A.4    Chao, C.P.5    Haaga, J.R.6
  • 26
    • 0025371538 scopus 로고
    • Alcian blue: Reliable method for marking resection margins
    • Birch PJ, Jeffrey MJ, Andrews MIJ. Alcian blue: reliable method for marking resection margins. J Clin Pathol 1990;43:608-609.
    • (1990) J Clin Pathol , vol.43 , pp. 608-609
    • Birch, P.J.1    Jeffrey, M.J.2    Andrews, M.I.J.3
  • 27
    • 0025297131 scopus 로고
    • Differential marking of excision planes in screened breast lesions by organically coloured gelatins
    • Armstrong JS, Weinzwieg IP, Davies JP. Differential marking of excision planes in screened breast lesions by organically coloured gelatins. J Clin Pathol 1990;43:604-607.
    • (1990) J Clin Pathol , vol.43 , pp. 604-607
    • Armstrong, J.S.1    Weinzwieg, I.P.2    Davies, J.P.3
  • 28
    • 0041356955 scopus 로고    scopus 로고
    • Serial cardiac magnetic resonance imaging of injected mesenchymal stem cells
    • Hill JM, Dick AJ, Raman VK, et al. Serial cardiac magnetic resonance imaging of injected mesenchymal stem cells. Circulation 2003;108:1009-1014.
    • (2003) Circulation , vol.108 , pp. 1009-1014
    • Hill, J.M.1    Dick, A.J.2    Raman, V.K.3
  • 29
    • 30744449019 scopus 로고    scopus 로고
    • MR histological correlation: A method for cutting specimens along the imaging plane in animal or ex vivo experiments
    • Rouviere O, Reynolds C, Hulshizer T, et al. MR histological correlation: a method for cutting specimens along the imaging plane in animal or ex vivo experiments. J Magn Reson Imaging 2006;23:60-69.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 60-69
    • Rouviere, O.1    Reynolds, C.2    Hulshizer, T.3
  • 30
    • 0042510544 scopus 로고    scopus 로고
    • Elastographic measurement of the area and volume of thermal lesions resulting from radiofrequency ablation: Pathologic correlation
    • Varghese T, Techavipoo U, Liu W, et al. Elastographic measurement of the area and volume of thermal lesions resulting from radiofrequency ablation: pathologic correlation. AJR Am J Roentgenol 2003;181:701-707.
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 701-707
    • Varghese, T.1    Techavipoo, U.2    Liu, W.3
  • 31
    • 0024312515 scopus 로고
    • Experimental lymph node metastases enhanced detection with MR lymphography
    • Weissleder R, Elizondo G, Josephson L, et al. Experimental lymph node metastases enhanced detection with MR lymphography. Radiology 1989;171:835-839.
    • (1989) Radiology , vol.171 , pp. 835-839
    • Weissleder, R.1    Elizondo, G.2    Josephson, L.3
  • 32
    • 0034753215 scopus 로고    scopus 로고
    • Superparamagnetic iron oxide contrast agents: Physicochemical characteristics and applications in MR imaging
    • Xiang YX, Hussain SM, Krestin GP. Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in MR imaging. Eur Radiol 2001;11:2319-2331.
    • (2001) Eur Radiol , vol.11 , pp. 2319-2331
    • Xiang, Y.X.1    Hussain, S.M.2    Krestin, G.P.3
  • 33
    • 0344301901 scopus 로고    scopus 로고
    • Liver imaging with ferumoxides (feridex): Fundamentals, controversies, and practical aspects
    • Clément O, Siauve N, Cuénod CA, Frija G. Liver imaging with ferumoxides (feridex): fundamentals, controversies, and practical aspects. Top Magn Reson Imaging 1998;9:167-182.
    • (1998) Top Magn Reson Imaging , vol.9 , pp. 167-182
    • Clément, O.1    Siauve, N.2    Cuénod, C.A.3    Frija, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.