메뉴 건너뛰기




Volumn 27, Issue 1, 2005, Pages 25-33

The design of planar gradient coils. Part II: A weighted superposition method

Author keywords

Gradient coil; Insertable; Minimum inductance; MRI; Optimization; Planar; Simulated annealing; Target field method

Indexed keywords


EID: 30744453529     PISSN: 15525031     EISSN: None     Source Type: Journal    
DOI: 10.1002/cmr.b.20050     Document Type: Article
Times cited : (10)

References (15)
  • 1
    • 18444410579 scopus 로고    scopus 로고
    • Design and implementation of a uniplanar gradient field coil for magnetic resonance imaging
    • Lemdiasov R, Ludwig R, Brevard M, Ferris C. 2004. Design and implementation of a uniplanar gradient field coil for magnetic resonance imaging. Concepts Magn Reson B (Magn Reson Eng) 20B(1):17-29.
    • (2004) Concepts Magn Reson B (Magn Reson Eng) , vol.20 B , Issue.1 , pp. 17-29
    • Lemdiasov, R.1    Ludwig, R.2    Brevard, M.3    Ferris, C.4
  • 2
    • 0036472830 scopus 로고    scopus 로고
    • Rapid field calculations for the effect of ferromagnetic material in MRI magnet design
    • Zhao H, Crozier S. 2002. Rapid field calculations for the effect of ferromagnetic material in MRI magnet design. Measurement Sci Technol 13:198-205.
    • (2002) Measurement Sci Technol , vol.13 , pp. 198-205
    • Zhao, H.1    Crozier, S.2
  • 3
    • 0035108688 scopus 로고    scopus 로고
    • Stream function optimization for gradient coil design
    • Tomasi D. 2001. Stream function optimization for gradient coil design. Magn Reson Imaging 45:505-512.
    • (2001) Magn Reson Imaging , vol.45 , pp. 505-512
    • Tomasi, D.1
  • 8
    • 0030208868 scopus 로고    scopus 로고
    • A field-gradient coil using concentric return paths
    • Brey WW, Mareci TH, Dougherty J. 1996. A field-gradient coil using concentric return paths. J Magn Reson 112:124-120.
    • (1996) J Magn Reson , vol.112 , pp. 124-1120
    • Brey, W.W.1    Mareci, T.H.2    Dougherty, J.3
  • 9
    • 0033293743 scopus 로고    scopus 로고
    • A design method for minimum-inductance planar magnetic-resonance-imaging gradient coils considering the pole piece effect
    • Moon CH, Park HW, Lee SY. 1999. A design method for minimum-inductance planar magnetic-resonance-imaging gradient coils considering the pole piece effect. Measurement Sci Technol 10:136-141.
    • (1999) Measurement Sci Technol , vol.10 , pp. 136-141
    • Moon, C.H.1    Park, H.W.2    Lee, S.Y.3
  • 11
    • 0035983160 scopus 로고    scopus 로고
    • Short planar gradient coils for MR microscopy using concentric return paths
    • Dodd SJ, Ho C. 2002. Short planar gradient coils for MR microscopy using concentric return paths. J Magn Reson 156:1-9.
    • (2002) J Magn Reson , vol.156 , pp. 1-9
    • Dodd, S.J.1    Ho, C.2
  • 12
    • 0000862096 scopus 로고    scopus 로고
    • Multilayer gradient coil design
    • Bowtell R, Robyr P. 1998. Multilayer gradient coil design. J Magn Reson 131:286-294.
    • (1998) J Magn Reson , vol.131 , pp. 286-294
    • Bowtell, R.1    Robyr, P.2
  • 13
    • 0012108027 scopus 로고    scopus 로고
    • Engineering B, Neuman MR, editor. Boca Raton, FL: CRC Press LLC
    • Jin J. 1999. Electromagnetic Analysis and Design. Engineering B, Neuman MR, editor. Boca Raton, FL: CRC Press LLC.
    • (1999) Electromagnetic Analysis and Design
    • Jin, J.1
  • 15
    • 0027369131 scopus 로고
    • Gradient coil design: A review of methods
    • Turner R. 1993. Gradient coil design: A review of methods. Magn Reson Imag 11:903-920.
    • (1993) Magn Reson Imag , vol.11 , pp. 903-920
    • Turner, R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.