메뉴 건너뛰기




Volumn 23, Issue 1, 2006, Pages 92-97

Recording high quality speech during tagged cine-MRI studies using a fiber optic microphone

Author keywords

Audibility; Audio; MRI; Speech; Tongue

Indexed keywords

ADULT; APPARATUS; ARTICLE; AUDIO RECORDING; COMPLEMENTARY SPATIAL MODULATION OF MAGNETIZATION TAGGED CINE SEQUENCE; COMPUTER; ELECTROCARDIOGRAM; FEASIBILITY STUDY; FIBER OPTICS; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; IMAGING SYSTEM; MALE; MICROPHONE; NOISE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUALITY CONTROL; REPRODUCIBILITY; SIGNAL DETECTION; SIMULATOR; SPECTROSCOPY; SPEECH; TONGUE; WAVEFORM;

EID: 30744449537     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.20463     Document Type: Article
Times cited : (47)

References (8)
  • 1
    • 0034973941 scopus 로고    scopus 로고
    • Modeling the motion of the internal tongue from tagged cine-MRI images
    • Stone M, Davis EP, Douglas AS, et al. Modeling the motion of the internal tongue from tagged cine-MRI images. J Acoust Soc Am 2001;109:2974-2982.
    • (2001) J Acoust Soc Am , vol.109 , pp. 2974-2982
    • Stone, M.1    Davis, E.P.2    Douglas, A.S.3
  • 2
    • 0035659076 scopus 로고    scopus 로고
    • Modeling tongue surface contours from Cine-MRI images
    • Stone M, Davis EP, Douglas AS, et al. Modeling tongue surface contours from Cine-MRI images. J Speech Lang Hear Res 2001;44:1026-1040.
    • (2001) J Speech Lang Hear Res , vol.44 , pp. 1026-1040
    • Stone, M.1    Davis, E.P.2    Douglas, A.S.3
  • 3
    • 0029135232 scopus 로고
    • Refractive fiber optic microphones with ambient acoustic noise-canceling capabilities
    • Jost BM, Stec JP. Refractive fiber optic microphones with ambient acoustic noise-canceling capabilities. J Acoust Soc Am 1995;98:1612-1617.
    • (1995) J Acoust Soc Am , vol.98 , pp. 1612-1617
    • Jost, B.M.1    Stec, J.P.2
  • 6
    • 0042092054 scopus 로고    scopus 로고
    • Magnitude image CSPAMM reconstruction (MICSR)
    • NessAiver M, Prince JL. Magnitude image CSPAMM reconstruction (MICSR). Magn Reson Med 2003;50:331-342.
    • (2003) Magn Reson Med , vol.50 , pp. 331-342
    • NessAiver, M.1    Prince, J.L.2
  • 8
    • 0033185197 scopus 로고    scopus 로고
    • MRI-based speech production study using a synchronized sampling method
    • Masaki S, Tiede M, Honda K, Shimada Y, Fujimoto I, et al. MRI-based speech production study using a synchronized sampling method. J Acoust Soc Jpn 1999;20:375-379.
    • (1999) J Acoust Soc Jpn , vol.20 , pp. 375-379
    • Masaki, S.1    Tiede, M.2    Honda, K.3    Shimada, Y.4    Fujimoto, I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.