메뉴 건너뛰기




Volumn 76, Issue 1, 2006, Pages 86-94

Fluorinated diamond-like carbon as antithrombogenic coating for blood-contacting devices

Author keywords

Biocompatibility; Fluorinated diamond like carbon film; Hemocompatibility; Hydrophobicity; Thrombogenicity

Indexed keywords

BIOCOMPATIBILITY; BLOOD; CARDIOVASCULAR SYSTEM; COATED MATERIALS; COATINGS; HYDROPHOBICITY; IMPLANTS (SURGICAL);

EID: 30444452970     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.a.30512     Document Type: Article
Times cited : (92)

References (28)
  • 1
    • 0028022533 scopus 로고
    • Inflammation and foreign body response
    • Anderson JM. Inflammation and foreign body response. Prob Gen Surg 1994;11:147-160.
    • (1994) Prob Gen Surg , vol.11 , pp. 147-160
    • Anderson, J.M.1
  • 3
    • 0027220495 scopus 로고
    • Diamond-like carbon: A potential means of reducing wear in total joint replacements
    • Dearnaley G. Diamond-like carbon: a potential means of reducing wear in total joint replacements. Clin Mater 1993;12:237-244.
    • (1993) Clin Mater , vol.12 , pp. 237-244
    • Dearnaley, G.1
  • 4
    • 0027791942 scopus 로고
    • Diamond-like carbon as biological compatible material for cell culture and medical application
    • Lu L, Jones MW, Wu RL. Diamond-like carbon as biological compatible material for cell culture and medical application. Biomed Mater Eng 1993;3:223-228.
    • (1993) Biomed Mater Eng , vol.3 , pp. 223-228
    • Lu, L.1    Jones, M.W.2    Wu, R.L.3
  • 5
    • 0031996361 scopus 로고    scopus 로고
    • Some relevant issues related to the use of amorphous diamond coating for medical applications
    • Lappalainen R, Heinonen H, Anttila A, Santavirta S. Some relevant issues related to the use of amorphous diamond coating for medical applications. Diamond Relat Mater 1998;7:482-485.
    • (1998) Diamond Relat Mater , vol.7 , pp. 482-485
    • Lappalainen, R.1    Heinonen, H.2    Anttila, A.3    Santavirta, S.4
  • 6
    • 0033971833 scopus 로고    scopus 로고
    • Titanium containing amorphous hydrogenated carbon films (a-C: H/Ti): Surface analysis and evaluation of cellular reactions using bone marrow cell cultures in vitro
    • Schroeder A, Francz G, Bruinink A, Hauert R, Mayer J, Wintermantel E. Titanium containing amorphous hydrogenated carbon films (a-C: H/Ti): surface analysis and evaluation of cellular reactions using bone marrow cell cultures in vitro. Biomaterials 2000;21:449-456.
    • (2000) Biomaterials , vol.21 , pp. 449-456
    • Schroeder, A.1    Francz, G.2    Bruinink, A.3    Hauert, R.4    Mayer, J.5    Wintermantel, E.6
  • 7
    • 0032052655 scopus 로고    scopus 로고
    • Morphological behaviour of osteoblasts on diamond-like carbon coating and amorphous C-N film in organ culture
    • Du C, Su XW, Cui FZ, Zhu XD. Morphological behaviour of osteoblasts on diamond-like carbon coating and amorphous C-N film in organ culture. Biomaterials 1998;19:651-658.
    • (1998) Biomaterials , vol.19 , pp. 651-658
    • Du, C.1    Su, X.W.2    Cui, F.Z.3    Zhu, X.D.4
  • 8
    • 0035728743 scopus 로고    scopus 로고
    • In vitro and in vivo investigations into the biocompatibility of diamond-like carbon (DLC) coatings for orthopedic applications
    • Allen M, Myer B, Rushton N. In vitro and in vivo investigations into the biocompatibility of diamond-like carbon (DLC) coatings for orthopedic applications. J Biomed Mater Res 2001;58:319-328.
    • (2001) J Biomed Mater Res , vol.58 , pp. 319-328
    • Allen, M.1    Myer, B.2    Rushton, N.3
  • 9
    • 0034043773 scopus 로고    scopus 로고
    • An in vitro investigation of diamond-like carbon as a femoral head coating
    • Affatato S, Frigo M, Tord A. An in vitro investigation of diamond-like carbon as a femoral head coating. J Biomed Mater Res 2000;53:221-226.
    • (2000) J Biomed Mater Res , vol.53 , pp. 221-226
    • Affatato, S.1    Frigo, M.2    Tord, A.3
  • 10
    • 0028606733 scopus 로고
    • The effects of diamond-like carbon coatings on macrophages, fibroblasts and osteoblast-like cells in vitro
    • Allen M, Law F, Rushton N. The effects of diamond-like carbon coatings on macrophages, fibroblasts and osteoblast-like cells in vitro. Clin Mater 1994;17:1-10.
    • (1994) Clin Mater , vol.17 , pp. 1-10
    • Allen, M.1    Law, F.2    Rushton, N.3
  • 11
    • 0036132132 scopus 로고    scopus 로고
    • Adhesion, cytoskeletal architecture and activation status of primary human macrophages on a diamond-like carbon coated surface
    • Linder S, Pinkowski W, Aepfelbacher M. Adhesion, cytoskeletal architecture and activation status of primary human macrophages on a diamond-like carbon coated surface. Biomaterials 2002;23:767-773.
    • (2002) Biomaterials , vol.23 , pp. 767-773
    • Linder, S.1    Pinkowski, W.2    Aepfelbacher, M.3
  • 14
    • 0034666723 scopus 로고    scopus 로고
    • In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity
    • Gutensohn K, Beythien C, Bau J, Fenner T, Grewe P, Koester R, Padmanaban K, Kuehnl P. In vitro analyses of diamond-like carbon coated stents. Reduction of metal ion release, platelet activation, and thrombogenicity. Thromb Res 2000;99:577-585.
    • (2000) Thromb Res , vol.99 , pp. 577-585
    • Gutensohn, K.1    Beythien, C.2    Bau, J.3    Fenner, T.4    Grewe, P.5    Koester, R.6    Padmanaban, K.7    Kuehnl, P.8
  • 17
    • 0034536367 scopus 로고    scopus 로고
    • The effect of fluorinated surface modifying macromolecules or the surface morphology of polyethersulfone membranes
    • Ho JY, Matsuura T, Santerre JP. The effect of fluorinated surface modifying macromolecules or the surface morphology of polyethersulfone membranes. J Biomater Sci Polym Ed 2000;11:1085-1104.
    • (2000) J Biomater Sci Polym Ed , vol.11 , pp. 1085-1104
    • Ho, J.Y.1    Matsuura, T.2    Santerre, J.P.3
  • 18
    • 0022793468 scopus 로고
    • Properties of polymeric layers of amorphous hydrogenated carbon produced by a plasma-activated chemical vapour deposition process I: Spectroscopic investigations
    • Memming R. Properties of polymeric layers of amorphous hydrogenated carbon produced by a plasma-activated chemical vapour deposition process I: Spectroscopic investigations. Thin Solid Films 1986;143:279-289.
    • (1986) Thin Solid Films , vol.143 , pp. 279-289
    • Memming, R.1
  • 20
    • 0037852937 scopus 로고    scopus 로고
    • A review of modified DLC coatings for biological applications
    • Hauert R. A review of modified DLC coatings for biological applications. Diam Relat Mater 2003;12:583-589.
    • (2003) Diam Relat Mater , vol.12 , pp. 583-589
    • Hauert, R.1
  • 21
    • 0142185044 scopus 로고    scopus 로고
    • Properties of fluorinated amorphous diamond like carbon films by PECVD
    • Yu GQ, Tay BK, Sun Z, Pan LK. Properties of fluorinated amorphous diamond like carbon films by PECVD. Applied Surface Science 2003;219:228-237.
    • (2003) Applied Surface Science , vol.219 , pp. 228-237
    • Yu, G.Q.1    Tay, B.K.2    Sun, Z.3    Pan, L.K.4
  • 22
    • 0347412033 scopus 로고    scopus 로고
    • Mechanical properties evaluation of fluor-doped diamond-like carbon coatings by nanoindentation
    • Trippe SC, Mansano RD, Costa FM, Suva RF. Mechanical properties evaluation of fluor-doped diamond-like carbon coatings by nanoindentation. Thin Solid Films 2004;446:85-90.
    • (2004) Thin Solid Films , vol.446 , pp. 85-90
    • Trippe, S.C.1    Mansano, R.D.2    Costa, F.M.3    Suva, R.F.4
  • 24
    • 0030840789 scopus 로고    scopus 로고
    • Activation of coagulation and platelets is affected by the hydrophobicity of artificial surfaces
    • Hunt BJ, Parratt R, Cable M, Finch D, Yacoub M. Activation of coagulation and platelets is affected by the hydrophobicity of artificial surfaces. Blood Coagul Fibrinolysis 1997;8:223-231.
    • (1997) Blood Coagul Fibrinolysis , vol.8 , pp. 223-231
    • Hunt, B.J.1    Parratt, R.2    Cable, M.3    Finch, D.4    Yacoub, M.5
  • 25
  • 26
    • 0036132492 scopus 로고    scopus 로고
    • Platelet adhesion and activation on a shielded plasma gradient prepared on polyethylene
    • Spijker HT, Bos R, Busscher HJ, von Kooten TG, von Oeveren W. Platelet adhesion and activation on a shielded plasma gradient prepared on polyethylene. Biomaterials 2002;23:757-766.
    • (2002) Biomaterials , vol.23 , pp. 757-766
    • Spijker, H.T.1    Bos, R.2    Busscher, H.J.3    Von Kooten, T.G.4    Von Oeveren, W.5
  • 27
    • 0034450007 scopus 로고    scopus 로고
    • Stainless steel in bone surgery
    • Disegi JA, Eschbach L. Stainless steel in bone surgery. Injury 2000;31 Suppl 4:2-6.
    • (2000) Injury , vol.31 , Issue.SUPPL. 4 , pp. 2-6
    • Disegi, J.A.1    Eschbach, L.2
  • 28
    • 0035255416 scopus 로고    scopus 로고
    • Proliferation and differentiation parameters of human osteoblasts on titanium and steel surfaces
    • Schmidt C, Ignatius AA, Claes LE. Proliferation and differentiation parameters of human osteoblasts on titanium and steel surfaces. J Biomed Mater Res 2001;54:209-215.
    • (2001) J Biomed Mater Res , vol.54 , pp. 209-215
    • Schmidt, C.1    Ignatius, A.A.2    Claes, L.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.