메뉴 건너뛰기




Volumn 91, Issue 6, 2000, Pages 297-300

"Pinch-off" syndrome and fracture of permanently implanted venous access;Sindrome del "pinch off" e rottura di accesso venoso totalmente impiantato. Descrizione di un caso

Author keywords

"Pinch off" syndrome; Central venous catheters; Fracture and embolization; Tumors

Indexed keywords

ARTICLE; CASE REPORT; CENTRAL VENOUS CATHETERIZATION; EQUIPMENT; FEMALE; HUMAN; MIDDLE AGED; SYNDROME;

EID: 3042937121     PISSN: 00341193     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0021914132 scopus 로고
    • Complications and management of implanted venous access catheters
    • Lokich JK, Both A Jr, Benotti P et al. Complications and management of implanted venous access catheters. J Clin Oncol 1985; 3: 710-7.
    • (1985) J Clin Oncol , vol.3 , pp. 710-717
    • Lokich, J.K.1    Both Jr., A.2    Benotti, P.3
  • 2
    • 0028300817 scopus 로고
    • Catheter-related infection associated with home parenteral nutrition and predictive factors for the need for catheter removal in their treatment
    • Buchman AI, Moukarzel A, Goodson B et al. Catheter-related infection associated with home parenteral nutrition and predictive factors for the need for catheter removal in their treatment. JPEN 1994; 18; 297-302.
    • (1994) JPEN , vol.18 , pp. 297-302
    • Buchman, A.I.1    Moukarzel, A.2    Goodson, B.3
  • 4
    • 0029355389 scopus 로고
    • Rare complications of vascular access devices
    • Ingle RJ. Rare complications of vascular access devices. Sem Oncol Nursing 1995; 11: 184-93.
    • (1995) Sem Oncol Nursing , vol.11 , pp. 184-193
    • Ingle, R.J.1
  • 5
    • 0024244014 scopus 로고
    • Complications associated with central venous catheters: A survey
    • Scott WL. Complications associated with central venous catheters: a survey. Chest 1988; 94: 1221-4.
    • (1988) Chest , vol.94 , pp. 1221-1224
    • Scott, W.L.1
  • 6
    • 0025887294 scopus 로고
    • Indwelling subclavian cetheters and a visit with the "pinch-off" sign
    • Lafreniere R. Indwelling subclavian cetheters and a visit with the "pinch-off" sign. J Surg Oncol 1991; 47: 261-4.
    • (1991) J Surg Oncol , vol.47 , pp. 261-264
    • Lafreniere, R.1
  • 7
    • 0027670676 scopus 로고
    • Central venous catheter "pinch-off" and fracture: A review of two under recognized complications
    • Nace CS, Ingle RJ. Central venous catheter "pinch-off" and fracture: a review of two under recognized complications. Oncol Nursing Forum 1993; 20: 1227-36.
    • (1993) Oncol Nursing Forum , vol.20 , pp. 1227-1236
    • Nace, C.S.1    Ingle, R.J.2
  • 8
    • 0025043250 scopus 로고
    • Pinch-off syndrome: A complication of implantable subclavian access devices
    • Hinke DH, Zandt-Stastny DA, Goodman LR, et Al. Pinch-off syndrome: a complication of implantable subclavian access devices. Radiology 1990; 177: 353-6.
    • (1990) Radiology , vol.177 , pp. 353-356
    • Hinke, D.H.1    Zandt-Stastny, D.A.2    Goodman, L.R.3
  • 9
    • 0021705456 scopus 로고
    • The "pinch-off sign": A warning of impending problems with permanent subclavian catheters
    • Aitken DR, Minton JP. The "pinch-off sign": a warning of impending problems with permanent subclavian catheters. Am J Surg 1984; 148: 633-6.
    • (1984) Am J Surg , vol.148 , pp. 633-636
    • Aitken, D.R.1    Minton, J.P.2
  • 10
    • 0023223019 scopus 로고
    • Spontaneous intravenous catheter fracture and embolization from an implanted venous access port and analysis by scanning electron microscopy
    • Prager D, Hertzberg RW. Spontaneous intravenous catheter fracture and embolization from an implanted venous access port and analysis by scanning electron microscopy. Cancer 1987; 60: 270-3.
    • (1987) Cancer , vol.60 , pp. 270-273
    • Prager, D.1    Hertzberg, R.W.2
  • 12
    • 0029090747 scopus 로고
    • The "pinch-off phenomenon": A radiological symptom for potential fracture of an implanted permanent subclavian catheter system
    • Schlangen JT, Debets JMH, Wils JA. The "pinch-off phenomenon": a radiological symptom for potential fracture of an implanted permanent subclavian catheter system. Eur J Radiol 1995;20: 112-3.
    • (1995) Eur J Radiol , vol.20 , pp. 112-113
    • Schlangen, J.T.1    Debets, J.M.H.2    Wils, J.A.3
  • 13
    • 0027715867 scopus 로고
    • Catheter fracture: A complication in venous access devices
    • McMenamin EM. Catheter fracture: a complication in venous access devices. Cancer Nursing 1993; 16: 464-7.
    • (1993) Cancer Nursing , vol.16 , pp. 464-467
    • McMenamin, E.M.1
  • 14
    • 0017836814 scopus 로고
    • Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies
    • Fisher RG, Ferreyro R. Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies. Am J Roentgenol 1978; 130: 541-8.
    • (1978) Am J Roentgenol , vol.130 , pp. 541-548
    • Fisher, R.G.1    Ferreyro, R.2
  • 15
    • 0026603696 scopus 로고
    • Breakage of an embolized intravascular catheter fragment: A complication of nonsurgical transvenous retrieval
    • Bauch TD, Stoughton TL, Pearl W. Breakage of an embolized intravascular catheter fragment: a complication of nonsurgical transvenous retrieval. JPEN 1992; 16: 175-7.
    • (1992) JPEN , vol.16 , pp. 175-177
    • Bauch, T.D.1    Stoughton, T.L.2    Pearl, W.3
  • 16
    • 0024600693 scopus 로고
    • Catheter embolization from implanted venous access devices: Case reports
    • Carr ME Jr. Catheter embolization from implanted venous access devices: case reports. Angiology 1989; 40: 319-23.
    • (1989) Angiology , vol.40 , pp. 319-323
    • Carr Jr., M.E.1
  • 17
    • 0032427703 scopus 로고    scopus 로고
    • Catheter fracture and embolization from totally implanted venous access ports
    • Vadlamani P, Dawn B, Perry MC. Catheter fracture and embolization from totally implanted venous access ports. Case reports. Angiology 1998; 49: 1013-6.
    • (1998) Case Reports. Angiology , vol.49 , pp. 1013-1016
    • Vadlamani, P.1    Dawn, B.2    Perry, M.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.