메뉴 건너뛰기




Volumn 85, Issue 5 I, 2004, Pages 619-625

Practical measurement of radiation dose in pediatric radiology: Use of the dose-area product in digital fluoroscopy and neonatal chest radiographs;Mesure pratique de l'irradiation en radiopédiatrie: Utilisation du produit dose surface en fluorographie numérique et pour les radiographies pulmonaires néonatales

Author keywords

Chest radiographs; Child; Dose area product; Fluoroscopy; Radiation

Indexed keywords

ARTICLE; BODY WEIGHT; CHILD; DIAGNOSTIC IMAGING; DIGITAL RADIOGRAPHY; DOSE CALCULATION; FLUOROSCOPY; GASTROINTESTINAL RADIOGRAPHY; HUMAN; INTRAVENOUS UROGRAPHY; MAJOR CLINICAL STUDY; MICTURITION CYSTOURETHROGRAPHY; RADIATION DOSE; THORAX RADIOGRAPHY;

EID: 3042858211     PISSN: 02210363     EISSN: None     Source Type: Journal    
DOI: 10.1016/s0221-0363(04)97638-x     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 0035139873 scopus 로고    scopus 로고
    • Estimated risks of radiation-induced fatal cancer from pediatric CT
    • Brenner D, Elliston C, Hall E, Berdon W. Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 2001;176:289-96.
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 289-296
    • Brenner, D.1    Elliston, C.2    Hall, E.3    Berdon, W.4
  • 2
    • 77953919755 scopus 로고    scopus 로고
    • Niveaux de références diagnostiques: Spé cificités de la démarche française en radiologie
    • Beauvais-March H, Valero M, Biau A, Bourguignon M. Niveaux de références diagnostiques: spécificités de la démarche française en radiologie. Radioprotection 2003;38:187-200.
    • (2003) Radioprotection , vol.38 , pp. 187-200
    • Beauvais-March, H.1    Valero, M.2    Biau, A.3    Bourguignon, M.4
  • 4
    • 0034872246 scopus 로고    scopus 로고
    • Differences in effective dose estimation from dose-area product and entrance surface dose measurements in intravenous urography
    • Yakoumakis E, Tsalafoutas IA, Nikolaou D, Nazos I, Koulentianos E, Proukakis C. Differences in effective dose estimation from dose-area product and entrance surface dose measurements in intravenous urography. Br J Radiol 2001; 74:727-34.
    • (2001) Br J Radiol , vol.74 , pp. 727-734
    • Yakoumakis, E.1    Tsalafoutas, I.A.2    Nikolaou, D.3    Nazos, I.4    Koulentianos, E.5    Proukakis, C.6
  • 5
    • 0031849861 scopus 로고    scopus 로고
    • Dose reduction in a paediatric X-ray department following optimization of radiographic technique
    • Mooney R, Thomas PS. Dose reduction in a paediatric X-ray department following optimization of radiographic technique. Br J Radiol 1998;71:852-60.
    • (1998) Br J Radiol , vol.71 , pp. 852-860
    • Mooney, R.1    Thomas, P.S.2
  • 6
    • 0028048088 scopus 로고
    • A study of the relationship between patient dose and size in paediatric radiology
    • Martin CJ, Farquhar B, Stockdale E, MacDonald S. A study of the relationship between patient dose and size in paediatric radiology. Br J Radiol 1994;67:864-71.
    • (1994) Br J Radiol , vol.67 , pp. 864-871
    • Martin, C.J.1    Farquhar, B.2    Stockdale, E.3    MacDonald, S.4
  • 7
    • 0027319310 scopus 로고
    • Radiation doses to paediatric patients undergoing less common radiological procedures involving fluoroscopy
    • Chapple CL, Faulkner K, Lee RE, Hunter EW. Radiation doses to paediatric patients undergoing less common radiological procedures involving fluoroscopy. Br J Radiol 1993;66:823-7.
    • (1993) Br J Radiol , vol.66 , pp. 823-827
    • Chapple, C.L.1    Faulkner, K.2    Lee, R.E.3    Hunter, E.W.4
  • 8
    • 0026542234 scopus 로고
    • Results of a survey of doses to paediatric patients undergoing common radiological examinations
    • Chapple CL, Faulkner K, Lee RE, Hunter EW. Results of a survey of doses to paediatric patients undergoing common radiological examinations. Br J Radiol 1992;65:225-31.
    • (1992) Br J Radiol , vol.65 , pp. 225-231
    • Chapple, C.L.1    Faulkner, K.2    Lee, R.E.3    Hunter, E.W.4
  • 10
    • 0030021578 scopus 로고    scopus 로고
    • Dose-area product values in frequently performed complex paediatric radiology examinations
    • Ruiz MJ, Vano E, Gonzalez L, Fernandez JM. Dose-area product values in frequently performed complex paediatric radiology examinations. Br J Radiol 1996;69:160-4.
    • (1996) Br J Radiol , vol.69 , pp. 160-164
    • Ruiz, M.J.1    Vano, E.2    Gonzalez, L.3    Fernandez, J.M.4
  • 11
    • 0032781845 scopus 로고    scopus 로고
    • Radiation burden to paediatric patients due to micturating cystourethrography examinations in a Dutch children's hospital
    • Schultz FW, Geleijns J, Holscher HC, Weststrate J, Zonderland HM, Zoetelief J. Radiation burden to paediatric patients due to micturating cystourethrography examinations in a Dutch children's hospital. Br J Radiol 1999;72:763-72.
    • (1999) Br J Radiol , vol.72 , pp. 763-772
    • Schultz, F.W.1    Geleijns, J.2    Holscher, H.C.3    Weststrate, J.4    Zonderland, H.M.5    Zoetelief, J.6
  • 12
    • 0029006413 scopus 로고
    • The radiation dose to children from X-ray examinations of the pelvis and the urinary tract
    • Almen A, Mattsson S. The radiation dose to children from X-ray examinations of the pelvis and the urinary tract. Br J Radiol 1995;68:604-13.
    • (1995) Br J Radiol , vol.68 , pp. 604-613
    • Almen, A.1    Mattsson, S.2
  • 13
    • 0033693187 scopus 로고    scopus 로고
    • A study of the application of paediatric reference levels
    • Montgomery A, Martin CJ. A study of the application of paediatric reference levels. Br J Radiol 2000;73:1083-90.
    • (2000) Br J Radiol , vol.73 , pp. 1083-1090
    • Montgomery, A.1    Martin, C.J.2
  • 14
    • 0026505130 scopus 로고
    • The Reference Man in diagnostic radiology dosimetry
    • Lindskoug BA. The Reference Man in diagnostic radiology dosimetry. Br J Radiol 1992;65:431-7.
    • (1992) Br J Radiol , vol.65 , pp. 431-437
    • Lindskoug, B.A.1
  • 15
    • 0028036945 scopus 로고
    • Comparaison de la dose d'irradiation d'une cystographie conventionnelle ou numérisée chez l'enfant
    • Bourlière-Najean B, Panuel M, Faure F, Petit P, Devred P. Comparaison de la dose d'irradiation d'une cystographie conventionnelle ou numérisée chez l'enfant. Rev Im Med 1994;6:687-9.
    • (1994) Rev Im Med , vol.6 , pp. 687-689
    • Bourlière-Najean, B.1    Panuel, M.2    Faure, F.3    Petit, P.4    Devred, P.5
  • 18
    • 0031908617 scopus 로고    scopus 로고
    • Digital radiography in paediatrics: Radiation dose considerations and magnitude of possible dose reduction
    • Hufton AP, Doyle SM, Carty HM. Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction. Br I Radiol 1998; 71:186-99.
    • (1998) Br I Radiol , vol.71 , pp. 186-199
    • Hufton, A.P.1    Doyle, S.M.2    Carty, H.M.3
  • 19
    • 0029845516 scopus 로고    scopus 로고
    • Plaques photostimulables ou films conventionnels pour les clichés pulmonaires au lit en radiopédiatrie?
    • Maccia C, Ducou le Pointe H, Fery-Lemonnier E, et al. Plaques photostimulables ou films conventionnels pour les clichés pulmonaires au lit en radiopédiatrie? J Radiol 1996;77:1129-34.
    • (1996) J Radiol , vol.77 , pp. 1129-1134
    • Maccia, C.1    Ducou Le Pointe, H.2    Fery-Lemonnier, E.3
  • 20
    • 0032902271 scopus 로고    scopus 로고
    • Diagnostic image quality of mobile neonatal chest X-rays and the radiation exposure incurred
    • Lowe A, Finch A, Boniface D, Chaudhuri R, Shekhdar J. Diagnostic image quality of mobile neonatal chest X-rays and the radiation exposure incurred. Br J Radiol 1999;72:55-61.
    • (1999) Br J Radiol , vol.72 , pp. 55-61
    • Lowe, A.1    Finch, A.2    Boniface, D.3    Chaudhuri, R.4    Shekhdar, J.5
  • 21
    • 0036316052 scopus 로고    scopus 로고
    • Radiation dose quantities and risk in neonates in a special care baby unit
    • Armpilia CI, Fife IA, Croasdale PL. Radiation dose quantities and risk in neonates in a special care baby unit. Br J Radiol 2002;75:590-5.
    • (2002) Br J Radiol , vol.75 , pp. 590-595
    • Armpilia, C.I.1    Fife, I.A.2    Croasdale, P.L.3
  • 23
    • 0035159408 scopus 로고    scopus 로고
    • Neonatal chest and abdominal radiation dosimetry: A comparison of two radiographic techniques
    • Jones NF, Palarm TW, Negus IS. Neonatal chest and abdominal radiation dosimetry: a comparison of two radiographic techniques. Br J Radiol 2001;74:920-5.
    • (2001) Br J Radiol , vol.74 , pp. 920-925
    • Jones, N.F.1    Palarm, T.W.2    Negus, I.S.3
  • 24
    • 0038664344 scopus 로고    scopus 로고
    • Investigation of dose reduction in neonatal radiography using specially designed phantoms and LiF:Mg, Cu, P TLDs
    • Duggan L, Warren-Forward H, Smith T, Kron T. Investigation of dose reduction in neonatal radiography using specially designed phantoms and LiF:Mg, Cu, P TLDs. Br J Radiol 2003;76:232-7.
    • (2003) Br J Radiol , vol.76 , pp. 232-237
    • Duggan, L.1    Warren-Forward, H.2    Smith, T.3    Kron, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.