메뉴 건너뛰기




Volumn 122, Issue 1, 2004, Pages 128-134

Identification of unsuspected PNH-type cells in flow cytometric immunophenotypic analysis of peripheral blood and bone marrow

Author keywords

CD14; CD16; Flow cytometry; Paroxysmal nocturnal hemoglobinuria; PNH

Indexed keywords

CD14 ANTIGEN; CD16 ANTIGEN;

EID: 3042850681     PISSN: 00029173     EISSN: None     Source Type: Journal    
DOI: 10.1309/QQLFQU88XK435EPY     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 0028057807 scopus 로고
    • Paroxysmal nocturnal haemoglobinuria (PNH) is caused by somatic mutations in the pig-A gene
    • Bessler M, Mason PJ, Hillmen P, et al. Paroxysmal nocturnal haemoglobinuria (PNH) is caused by somatic mutations in the pig-A gene. EMBO J. 1994;13:110-117.
    • (1994) EMBO J , vol.13 , pp. 110-117
    • Bessler, M.1    Mason, P.J.2    Hillmen, P.3
  • 2
    • 0027310539 scopus 로고
    • Deficiency of the GPI anchor caused by a somatic mutation of the pig-A gene in paroxysmal nocturnal hemoglobinuria
    • Takeda J, Miyata T, Kawagoe K, et al. Deficiency of the GPI anchor caused by a somatic mutation of the pig-A gene in paroxysmal nocturnal hemoglobinuria. Cell. 1993;73:703-711.
    • (1993) Cell , vol.73 , pp. 703-711
    • Takeda, J.1    Miyata, T.2    Kawagoe, K.3
  • 3
    • 0034788057 scopus 로고    scopus 로고
    • Paroxysmal nocturnal hemoglobinuria: Insights from recent advances in molecular biology
    • Bessler M, Schaefer A, Keller P. Paroxysmal nocturnal hemoglobinuria: insights from recent advances in molecular biology. Transfus Med Rev. 2001;15:255-267.
    • (2001) Transfus Med Rev , vol.15 , pp. 255-267
    • Bessler, M.1    Schaefer, A.2    Keller, P.3
  • 4
    • 0037800971 scopus 로고
    • Affected erythrocytes of patients with paroxysmal nocturnal hemoglobinuria are deficient in the complement regulatory protein, decay accelerating factor
    • Nicholson-Weller A, March JP, Rosenfeld SI, et al. Affected erythrocytes of patients with paroxysmal nocturnal hemoglobinuria are deficient in the complement regulatory protein, decay accelerating factor. Proc Natl Acad Sci U S A. 1983;80:5066-5070.
    • (1983) Proc Natl Acad Sci U S A , vol.80 , pp. 5066-5070
    • Nicholson-Weller, A.1    March, J.P.2    Rosenfeld, S.I.3
  • 5
    • 0013911413 scopus 로고
    • Immune lysis of normal human and paroxysmal nocturnal hemoglobinuria (PNH) red blood cells, I: The sensitivity of PNH cells to lysis by complement and specific antibody
    • Rosse WF, Dacie JV. Immune lysis of normal human and paroxysmal nocturnal hemoglobinuria (PNH) red blood cells, I: the sensitivity of PNH cells to lysis by complement and specific antibody. J Clin Invest. 1966;45:736-748.
    • (1966) J Clin Invest , vol.45 , pp. 736-748
    • Rosse, W.F.1    Dacie, J.V.2
  • 6
    • 0032710713 scopus 로고    scopus 로고
    • Paroxysmal nocturnal hemoglobinuria: An acquired genetic disease
    • Nishimura J, Murakami Y, Kinoshita T. Paroxysmal nocturnal hemoglobinuria: an acquired genetic disease. Am J Hematol. 1999;62:175-182.
    • (1999) Am J Hematol , vol.62 , pp. 175-182
    • Nishimura, J.1    Murakami, Y.2    Kinoshita, T.3
  • 7
    • 0034520690 scopus 로고    scopus 로고
    • Paroxysmal nocturnal hemoglobinuria testing by flow cytometry: Evaluation of the REDQUANT and CELLQUANT kits
    • Hsi ED. Paroxysmal nocturnal hemoglobinuria testing by flow cytometry: evaluation of the REDQUANT and CELLQUANT kits. Am J Clin Pathol. 2000;114:798-806.
    • (2000) Am J Clin Pathol , vol.114 , pp. 798-806
    • Hsi, E.D.1
  • 8
    • 0029981029 scopus 로고    scopus 로고
    • The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria
    • Hall SE, Rosse WF. The use of monoclonal antibodies and flow cytometry in the diagnosis of paroxysmal nocturnal hemoglobinuria. Blood. 1996;87:5332-5340.
    • (1996) Blood , vol.87 , pp. 5332-5340
    • Hall, S.E.1    Rosse, W.F.2
  • 9
    • 0029748586 scopus 로고    scopus 로고
    • Blood cell flow cytometry in paroxysmal nocturnal hemoglobinuria: A tool for measuring the extent of the PNH clone
    • Alfinito F, Del Vecchio L, Rocco S, et al. Blood cell flow cytometry in paroxysmal nocturnal hemoglobinuria: a tool for measuring the extent of the PNH clone. Leukemia. 1996;10:1326-1330.
    • (1996) Leukemia , vol.10 , pp. 1326-1330
    • Alfinito, F.1    Del Vecchio, L.2    Rocco, S.3
  • 10
    • 0027380002 scopus 로고
    • Diagnosis of paroxysmal nocturnal haemoglobinuria by phenotypic analysis of erythrocytes using two-colour flow cytometry with monoclonal antibodies to DAF and CD59/MACIF
    • Shichishima T, Terasawa T, Saitoh Y, et al. Diagnosis of paroxysmal nocturnal haemoglobinuria by phenotypic analysis of erythrocytes using two-colour flow cytometry with monoclonal antibodies to DAF and CD59/MACIF. Br J Haematol. 1993;85:378-386.
    • (1993) Br J Haematol , vol.85 , pp. 378-386
    • Shichishima, T.1    Terasawa, T.2    Saitoh, Y.3
  • 11
    • 0025202564 scopus 로고
    • Deficiency of glycosyl-phosphatidylinositol-linked membrane glycoproteins of leukocytes in paroxysmal nocturnal hemoglobinuria, description of a new diagnostic cytofluorometric assay
    • van der Schoot CE, Huizinga TWJ, van't Veer-Korthof ET, et al. Deficiency of glycosyl-phosphatidylinositol-linked membrane glycoproteins of leukocytes in paroxysmal nocturnal hemoglobinuria, description of a new diagnostic cytofluorometric assay. Blood. 1990;76:1853-1859.
    • (1990) Blood , vol.76 , pp. 1853-1859
    • Van Der Schoot, C.E.1    Huizinga, T.W.J.2    Van't Veer-Korthof, E.T.3
  • 12
    • 0033836378 scopus 로고    scopus 로고
    • Application of flow cytometry to the diagnosis of paroxysmal nocturnal hemoglobinuria
    • Richards SJ, Rawstron AC, Hillmen P. Application of flow cytometry to the diagnosis of paroxysmal nocturnal hemoglobinuria. Cytometry. 2000;42:223-233.
    • (2000) Cytometry , vol.42 , pp. 223-233
    • Richards, S.J.1    Rawstron, A.C.2    Hillmen, P.3
  • 13
    • 0037096414 scopus 로고    scopus 로고
    • Comparative analysis of different flow cytometry-based immunophenotypic methods for the analysis of CD59 and CD55 expression on major peripheral blood cell subsets
    • Hemandez-Campo PM, Martin-Ayuso M, Almeida J, et al. Comparative analysis of different flow cytometry-based immunophenotypic methods for the analysis of CD59 and CD55 expression on major peripheral blood cell subsets. Cyrometry. 2002;50:191-201.
    • (2002) Cyrometry , vol.50 , pp. 191-201
    • Hemandez-Campo, P.M.1    Martin-Ayuso, M.2    Almeida, J.3
  • 14
    • 0027162898 scopus 로고
    • CD45 gating for routine flow cytometric analysis of human bone marrow specimens
    • Stelzer GT, Shults KE, Loken MR. CD45 gating for routine flow cytometric analysis of human bone marrow specimens. Ann N Y Acad Sci. 1993;20:265-280.
    • (1993) Ann N Y Acad Sci , vol.20 , pp. 265-280
    • Stelzer, G.T.1    Shults, K.E.2    Loken, M.R.3
  • 15
    • 0028245643 scopus 로고
    • Neutrophil apoptosis is associated with a reduction in CD16 (Fc gamma RIII) expression
    • Dransfield I, Buckle AM, Savill JS, et al. Neutrophil apoptosis is associated with a reduction in CD16 (Fc gamma RIII) expression. J Immunol. 1994;153:1254-1263.
    • (1994) J Immunol , vol.153 , pp. 1254-1263
    • Dransfield, I.1    Buckle, A.M.2    Savill, J.S.3
  • 16
    • 0035883086 scopus 로고    scopus 로고
    • Diagnostic utility of flow cytometric immunophenotyping in myelodysplastic syndrome
    • Stetler-Stevenson M, Arthur DC, Jabbour N, et al. Diagnostic utility of flow cytometric immunophenotyping in myelodysplastic syndrome. Blood. 2001;98:979-987.
    • (2001) Blood , vol.98 , pp. 979-987
    • Stetler-Stevenson, M.1    Arthur, D.C.2    Jabbour, N.3
  • 17
    • 0024555494 scopus 로고
    • Monocyte antigen CD14 is a phospholipid anchored membrane protein
    • Simmons DL, Tan S, Tenen DG, et al. Monocyte antigen CD14 is a phospholipid anchored membrane protein. Blood. 1989;73:284-289.
    • (1989) Blood , vol.73 , pp. 284-289
    • Simmons, D.L.1    Tan, S.2    Tenen, D.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.