메뉴 건너뛰기




Volumn 92, Issue 1, 2004, Pages 8-11

Distal implants to modify the Kennedy classification of a removable partial denture: A clinical report

Author keywords

[No Author keywords available]

Indexed keywords

CHROMIUM; COBALT; METAL;

EID: 3042834729     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.prosdent.2004.04.010     Document Type: Article
Times cited : (59)

References (16)
  • 1
    • 0015891167 scopus 로고
    • RPI (rest, proximal plate, I bar) clasp retainer and its modifications
    • Krol A. RPI (rest, proximal plate, I bar) clasp retainer and its modifications. Dent Clin North Am. 17:1973;631-649
    • (1973) Dent Clin North Am , vol.17 , pp. 631-649
    • Krol, A.1
  • 2
    • 0016221579 scopus 로고
    • Photoelastic analysis of pressure on teeth and bone supporting removable partial dentures
    • Kratochvil F.J., Caputo A.A. Photoelastic analysis of pressure on teeth and bone supporting removable partial dentures. J Prosthet Dent. 32:1974;52-61
    • (1974) J Prosthet Dent , vol.32 , pp. 52-61
    • Kratochvil, F.J.1    Caputo, A.A.2
  • 3
    • 0027682698 scopus 로고
    • Load transmission evaluation by removable distal-extension partial dentures using holographic interferometry
    • Pezzoli M., Appendino P., Calcagno L., Celasco M., Modica R. Load transmission evaluation by removable distal-extension partial dentures using holographic interferometry. J Dent. 21:1993;312-316
    • (1993) J Dent , vol.21 , pp. 312-316
    • Pezzoli, M.1    Appendino, P.2    Calcagno, L.3    Celasco, M.4    Modica, R.5
  • 4
    • 0030178725 scopus 로고    scopus 로고
    • Designing clasps for the asymmetric distal extension removable partial denture
    • Ben-Ur Z., Gorfil C., Shifman A. Designing clasps for the asymmetric distal extension removable partial denture. Int J Prosthodont. 9:1996;374-378
    • (1996) Int J Prosthodont , vol.9 , pp. 374-378
    • Ben-Ur, Z.1    Gorfil, C.2    Shifman, A.3
  • 5
    • 3042787558 scopus 로고    scopus 로고
    • Implants and removable partial dentures
    • J.S. Brudvik. Chicago: Quintessence Publishing Co
    • Brudvik J.S. Implants and removable partial dentures. Brudvik J.S. Advanced removable partial dentures. 1999;153-159 Quintessence Publishing Co, Chicago
    • (1999) Advanced Removable Partial Dentures , pp. 153-159
    • Brudvik, J.S.1
  • 6
    • 0027347182 scopus 로고
    • Distal extension removable partial dentures supported by implants and residual teeth: Considerations and case reports
    • Keltjens H.M., Kayser A.F., Hertel Rm Battistuzzi P.G. Distal extension removable partial dentures supported by implants and residual teeth: considerations and case reports. Int J Oral Maxillofac Implants. 8:1993;208-213
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 208-213
    • Keltjens, H.M.1    Kayser, A.F.2    Hertel Rm Battistuzzi, P.G.3
  • 7
    • 0030255713 scopus 로고    scopus 로고
    • Solving the distal extension removable partial denture base movement dilemma: A clinical report
    • Giffin K.M. Solving the distal extension removable partial denture base movement dilemma: a clinical report. J Prosthet Dent. 76:1996;347-349
    • (1996) J Prosthet Dent , vol.76 , pp. 347-349
    • Giffin, K.M.1
  • 10
    • 0025492383 scopus 로고
    • Abutment teeth with extracoronal attachments: The effects of splinting on tooth movement
    • Altay O.T., Tsolka P., Preiskel W.H. Abutment teeth with extracoronal attachments: the effects of splinting on tooth movement. Int J Prosthodont. 3:1990;441-448
    • (1990) Int J Prosthodont , vol.3 , pp. 441-448
    • Altay, O.T.1    Tsolka, P.2    Preiskel, W.H.3
  • 11
    • 0030227647 scopus 로고    scopus 로고
    • Effect of splinting on load distribution of extracoronal attachment with distal extension prosthesis in vitro
    • el Charkawi H.G., el Wakad M.T. Effect of splinting on load distribution of extracoronal attachment with distal extension prosthesis in vitro. J Prosthet Dent. 76:1996;315-320
    • (1996) J Prosthet Dent , vol.76 , pp. 315-320
    • El Charkawi, H.G.1    El Wakad, M.T.2
  • 12
    • 0026150991 scopus 로고
    • Precision attachment retained removable partial dentures: Part 1. Technical long-term study
    • Owäll B. Precision attachment retained removable partial dentures: Part 1. Technical long-term study. Int J Prosthodont. 4:1991;249-257
    • (1991) Int J Prosthodont , vol.4 , pp. 249-257
    • Owäll, B.1
  • 13
    • 0029179693 scopus 로고
    • Precision attachment-retained removable partial dentures: Part 2. Long-term study of ball attachments
    • Owäll B. Precision attachment-retained removable partial dentures: Part 2. Long-term study of ball attachments. Int J Prosthodont. 8:1995;21-28
    • (1995) Int J Prosthodont , vol.8 , pp. 21-28
    • Owäll, B.1
  • 14
    • 0020651579 scopus 로고
    • Retention and wear of precision-type attachments
    • Stewart B.L., Edwards R.O. Retention and wear of precision-type attachments. J Prosthet Dent. 49:1983;28-34
    • (1983) J Prosthet Dent , vol.49 , pp. 28-34
    • Stewart, B.L.1    Edwards, R.O.2
  • 15
    • 0021469584 scopus 로고
    • Attachment retained overdentures: A report on their maintenance requirements
    • Shaw M.J. Attachment retained overdentures: a report on their maintenance requirements. J Oral Rehabil. 11:1984;373-379
    • (1984) J Oral Rehabil , vol.11 , pp. 373-379
    • Shaw, M.J.1
  • 16
    • 0033182770 scopus 로고    scopus 로고
    • Wear behaviour of precision attachments
    • Wichmann M.G., Kuntze W. Wear behaviour of precision attachments. Int J Prosthodont. 12:1999;409-414
    • (1999) Int J Prosthodont , vol.12 , pp. 409-414
    • Wichmann, M.G.1    Kuntze, W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.