메뉴 건너뛰기




Volumn 1015, Issue , 2004, Pages 367-378

Novel approaches to reduce restenosis

Author keywords

Arterial remodeling; Coronary restenosis; Noontime proliferation; Stents

Indexed keywords

ABT 578; ANGIOPEPTIN; ANTINEOPLASTIC AGENT; BATIMASTAT; DACTINOMYCIN; DEXAMETHASONE; ESTROGEN; EVEROLIMUS; HALOFUGINONE; HEPARIN; METHOTREXATE; PACLITAXEL; PROBUCOL; RAPAMYCIN; TACROLIMUS; VASCULOTROPIN;

EID: 3042797865     PISSN: 00778923     EISSN: None     Source Type: Book Series    
DOI: 10.1196/annals.1302.032     Document Type: Conference Paper
Times cited : (30)

References (28)
  • 1
    • 3042791152 scopus 로고    scopus 로고
    • Arterial remodeling as a mechanism of restenosis following interventional coronary procedures: Evidence from serial ultrasound studies
    • R. Beyar, G. Keren, M. Leon & P.W. Serruys, Eds.: Martin Dunitz. London
    • MINTZ, G.S., K.M. KENT, J.L. POPMA, et al. 1997. Arterial remodeling as a mechanism of restenosis following interventional coronary procedures: evidence from serial ultrasound studies. In Frontiers in Interventional Cardiology. R. Beyar, G. Keren, M. Leon & P.W. Serruys, Eds.: 161-169. Martin Dunitz. London.
    • (1997) Frontiers in Interventional Cardiology , pp. 161-169
    • Mintz, G.S.1    Kent, K.M.2    Popma, J.L.3
  • 2
    • 0004396322 scopus 로고    scopus 로고
    • Stent design and the biologic response
    • R. Beyar, G. Keren, M. Leon & P.W. Serruys, Eds.: Martin Dunitz. London
    • GARASIC, J., C. ROGERS & E.R. EDELMAN. 1997. Stent design and the biologic response. In Frontiers in Interventional Cardiology. R. Beyar, G. Keren, M. Leon & P.W. Serruys, Eds.: 95-100. Martin Dunitz. London.
    • (1997) Frontiers in Interventional Cardiology , pp. 95-100
    • Garasic, J.1    Rogers, C.2    Edelman, E.R.3
  • 3
    • 0028123099 scopus 로고
    • A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease
    • SERRUYS, P.W., P. DE JAEGERE, F. KIEMENEIJ, et al. 1994. A comparison of balloon expandable stent implantation with balloon angioplasty in patients with coronary artery disease. N. Engl. J. Med. 331: 489-495.
    • (1994) N. Engl. J. Med. , vol.331 , pp. 489-495
    • Serruys, P.W.1    De Jaegere, P.2    Kiemeneij, F.3
  • 4
    • 0027934377 scopus 로고
    • A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease
    • FISHMAN, D.L., M.B. LEON, D.S. BAIM, et al. 1994. A randomized comparison of coronary stent placement and balloon angioplasty in the treatment of coronary artery disease. N. Engl. J. Med. 331: 496-501.
    • (1994) N. Engl. J. Med. , vol.331 , pp. 496-501
    • Fishman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 6
    • 0028357728 scopus 로고
    • Self expandable nitinol stent for cardiovascular applications: Canine and human experience
    • BEYAR, R., M. HENRY, R. SHOFTI, et al. 1994. Self expandable nitinol stent for cardiovascular applications: canine and human experience. Cathet. Cardiovasc. Diagn. 32: 162-170.
    • (1994) Cathet. Cardiovasc. Diagn. , vol.32 , pp. 162-170
    • Beyar, R.1    Henry, M.2    Shofti, R.3
  • 7
    • 0027996127 scopus 로고
    • Self expandable and highly flexible nitinol stent: Immediate and long term results in dogs
    • GRENADIER, E., S. SHOFTI, M. BEYAR, et al. 1994. Self expandable and highly flexible nitinol stent: immediate and long term results in dogs. Am. Heart J. 128: 870-878.
    • (1994) Am. Heart J. , vol.128 , pp. 870-878
    • Grenadier, E.1    Shofti, S.2    Beyar, M.3
  • 8
    • 0037502881 scopus 로고    scopus 로고
    • Comparison of a silicon carbide-coated stent versus a non-coated stent in human beings: The Tenax versus Nir Stent Study's long-term outcome
    • UNVERDORBEN, M., B. SIPPEL, R. DEGENHARDT, et al. 2003. Comparison of a silicon carbide-coated stent versus a non-coated stent in human beings: the Tenax versus Nir Stent Study's long-term outcome. Am. Heart J. 145: 17.
    • (2003) Am. Heart J. , vol.145 , pp. 17
    • Unverdorben, M.1    Sippel, B.2    Degenhardt, R.3
  • 9
    • 0034265760 scopus 로고    scopus 로고
    • Italian BiodivYsio open registry (BiodivYsio PC-coated stent): Study of clinical outcomes of the implant of a PC-coated coronary stent
    • GALLI, M., A. BARTORELLI, F. BEDOGNI, et al. 2000. Italian BiodivYsio open registry (BiodivYsio PC-coated stent): study of clinical outcomes of the implant of a PC-coated coronary stent. J. Invasive Cardiol. 12: 452-458.
    • (2000) J. Invasive Cardiol. , vol.12 , pp. 452-458
    • Galli, M.1    Bartorelli, A.2    Bedogni, F.3
  • 10
    • 0034175826 scopus 로고    scopus 로고
    • Clinical and angiographic outcome after coronary arterial stenting with the carbostent
    • ANTONIUCCI, D., A. BARTORELLI, R. VALENTI, et al. 2000. Clinical and angiographic outcome after coronary arterial stenting with the carbostent. Am. J. Cardiol. 85: 821-825.
    • (2000) Am. J. Cardiol. , vol.85 , pp. 821-825
    • Antoniucci, D.1    Bartorelli, A.2    Valenti, R.3
  • 11
    • 0035936526 scopus 로고    scopus 로고
    • Gold-coated NIR stents in porcine coronary arteries
    • EDELMAN, E.R., P. SEIFERT, A. GROOTHUIS, et al. 2001. Gold-coated NIR stents in porcine coronary arteries. Circulation 103: 429-434.
    • (2001) Circulation , vol.103 , pp. 429-434
    • Edelman, E.R.1    Seifert, P.2    Groothuis, A.3
  • 12
    • 0035849543 scopus 로고    scopus 로고
    • Intracoronary stenting and angiographic results - Strut thickness effect on restenosis outcome (ISAR-STEREO) trial
    • KASTRATI, A., J. MEHILLI, J. DIRSCHINGER, et al. 2001. Intracoronary stenting and angiographic results - strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 103: 2816-2821.
    • (2001) Circulation , vol.103 , pp. 2816-2821
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 13
    • 0035188478 scopus 로고    scopus 로고
    • Stent design related neointimal tissue proliferation in human coronary arteries - An intravascular ultrasound study
    • HOFFMANN, R., C. JANSEN, A. KONIG, et al. 2001. Stent design related neointimal tissue proliferation in human coronary arteries - an intravascular ultrasound study. Eur. Heart. J. 22: 2007-2014.
    • (2001) Eur. Heart. J. , vol.22 , pp. 2007-2014
    • Hoffmann, R.1    Jansen, C.2    Konig, A.3
  • 14
    • 0035178080 scopus 로고    scopus 로고
    • Restenosis after coronary placement of various stent types
    • KASTRATI, A., J. MEHILLI, J. DIRSCHINGER, et al. 2001. Restenosis after coronary placement of various stent types. Am. J. Cardiol. 87: 34-39.
    • (2001) Am. J. Cardiol. , vol.87 , pp. 34-39
    • Kastrati, A.1    Mehilli, J.2    Dirschinger, J.3
  • 15
    • 0031005933 scopus 로고    scopus 로고
    • Catheter-based radiotherapy to inhibit restenosis after coronary stenting
    • TEIRSTEIN, P.S., V. MASSULO, J. JANI, et al. 1997. Catheter-based radiotherapy to inhibit restenosis after coronary stenting. N. Engl. J. Med. 336: 1697-1703.
    • (1997) N. Engl. J. Med. , vol.336 , pp. 1697-1703
    • Teirstein, P.S.1    Massulo, V.2    Jani, J.3
  • 16
    • 0035945667 scopus 로고    scopus 로고
    • Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting
    • LEON, M.B., P.S. TEIRSTEIN, J.W. MOSES, et al. 2001. Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stenting. N. Engl. J. Med. 344: 250-256.
    • (2001) N. Engl. J. Med. , vol.344 , pp. 250-256
    • Leon, M.B.1    Teirstein, P.S.2    Moses, J.W.3
  • 17
    • 0035945670 scopus 로고    scopus 로고
    • Endoluminal beta-radiation therapy for the prevention of coronary restenosis after balloon angioplasty
    • VERIN, V., Y. POPOWSKI, B. BRUYNE, et al. 2001. Endoluminal beta-radiation therapy for the prevention of coronary restenosis after balloon angioplasty. N. Engl. J. Med. 344: 243-249.
    • (2001) N. Engl. J. Med. , vol.344 , pp. 243-249
    • Verin, V.1    Popowski, Y.2    Bruyne, B.3
  • 18
    • 0033600539 scopus 로고    scopus 로고
    • Late coronary occlusion after intracoronary brachytherapy
    • COSTA, M.A., M. SABATE, W.J. VAN DER GIESSEN, et al. 1999. Late coronary occlusion after intracoronary brachytherapy. Circulation 100: 789-792.
    • (1999) Circulation , vol.100 , pp. 789-792
    • Costa, M.A.1    Sabate, M.2    Van Der Giessen, W.J.3
  • 19
    • 0036241651 scopus 로고    scopus 로고
    • A prospective single-center registry for the use of intracoronary gamma radiation in patients with diffuse in-stent restenosis
    • NIKOLSKY, E., E. ROSENBLATT, E. GRENADIER, et al. 2002. A prospective single-center registry for the use of intracoronary gamma radiation in patients with diffuse in-stent restenosis. Cathet. Cardiovasc. Diagn. 56: 46-52.
    • (2002) Cathet. Cardiovasc. Diagn. , vol.56 , pp. 46-52
    • Nikolsky, E.1    Rosenblatt, E.2    Grenadier, E.3
  • 20
    • 0032578319 scopus 로고    scopus 로고
    • Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II)
    • SERRUYS, P.W., B. VAN HOUT, H. BONNIER, et al. FOR THE BENESTENT STUDY GROUP. 1998. Randomised comparison of implantation of heparin-coated stents with balloon angioplasty in selected patients with coronary artery disease (Benestent II). Lancet 352: 673-681.
    • (1998) Lancet , vol.352 , pp. 673-681
    • Serruys, P.W.1    Van Hout, B.2    Bonnier, H.3
  • 21
    • 0002323182 scopus 로고    scopus 로고
    • Stent-based sirolimus delivery reduces neointimal proliferation in a porcine coronary model of restenosis
    • CARTER, A.J., L.R. BAILEY, G. LIANOS, et al. 2000. Stent-based sirolimus delivery reduces neointimal proliferation in a porcine coronary model of restenosis. Am. Coll. Cardiol. 35 (Suppl. A): 13A-13A.
    • (2000) Am. Coll. Cardiol. , vol.35 , Issue.SUPPL. A
    • Carter, A.J.1    Bailey, L.R.2    Lianos, G.3
  • 22
    • 14344271133 scopus 로고    scopus 로고
    • Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: A quantitative coronary angiography and three-dimensional intravascular ultrasound study
    • SOUSA, J.E.M., M.A. COSTA, A. ABIZAID, et al. 2001. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries: a quantitative coronary angiography and three-dimensional intravascular ultrasound study. Circulation 103: 192-195.
    • (2001) Circulation , vol.103 , pp. 192-195
    • Sousa, J.E.M.1    Costa, M.A.2    Abizaid, A.3
  • 23
    • 0141863201 scopus 로고    scopus 로고
    • Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: Double-blind, randomised controlled trial (E-SIRIUS)
    • SCHOFER, J., M. SCHLUTER, A.H. GERSHLICK, et al. 2003. Sirolimus-eluting stents for treatment of patients with long atherosclerotic lesions in small coronary arteries: double-blind, randomised controlled trial (E-SIRIUS). Lancet 362: 1093-1099.
    • (2003) Lancet , vol.362 , pp. 1093-1099
    • Schofer, J.1    Schluter, M.2    Gershlick, A.H.3
  • 24
    • 0038711003 scopus 로고    scopus 로고
    • New frontiers in cardiology. Part I
    • SOUSA, J.E., P.W. SERRUYS, & M.A. COSTA. 2003. New frontiers in cardiology. Part I. Circulation 107: 2274-2279.
    • (2003) Circulation , vol.107 , pp. 2274-2279
    • Sousa, J.E.1    Serruys, P.W.2    Costa, M.A.3
  • 25
    • 0038476595 scopus 로고    scopus 로고
    • New frontiers in cardiology: Drug-eluting stents. Part II
    • SOUSA, J.E., P.W. SERRUYS & M.A. COSTA. 2003. New frontiers in cardiology: drug-eluting stents. Part II. Circulation 107: 2383-2389.
    • (2003) Circulation , vol.107 , pp. 2383-2389
    • Sousa, J.E.1    Serruys, P.W.2    Costa, M.A.3
  • 26
    • 3042752623 scopus 로고
    • The US pivotal randomized trial of a polymer-based slow-rate release paclitaxel eluting stent: 30-day results of TAXUS-IV SR
    • ELLIS, S.G., J.B. HERMILLER, D.A. COX, et al. 1954. The US pivotal randomized trial of a polymer-based slow-rate release paclitaxel eluting stent: 30-day results of TAXUS-IV SR. Circulation 106 (Suppl.): 2000.
    • (1954) Circulation , vol.106 , Issue.SUPPL. , pp. 2000
    • Ellis, S.G.1    Hermiller, J.B.2    Cox, D.A.3
  • 27
    • 0042388295 scopus 로고    scopus 로고
    • Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions
    • COLOMBO, A., J. DRZEWIECKI & A. BANNING. 2003. Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions. Circulation 108: 788-794.
    • (2003) Circulation , vol.108 , pp. 788-794
    • Colombo, A.1    Drzewiecki, J.2    Banning, A.3
  • 28
    • 0038340340 scopus 로고    scopus 로고
    • Investigation of corrosion behaviour of magnesium alloy AM60B-F under pseudo-physiological conditions
    • THERMEC 2003, PTS 1-5
    • LEVESQUE, J., D. DUBE, M. FISET, et al. 2003. Investigation of corrosion behaviour of magnesium alloy AM60B-F under pseudo-physiological conditions. THERMEC 2003, PTS 1-5. Mater. Sci. Forum 426: 521-526.
    • (2003) Mater. Sci. Forum , vol.426 , pp. 521-526
    • Levesque, J.1    Dube, D.2    Fiset, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.