메뉴 건너뛰기




Volumn 142, Issue 3, 2004, Pages 366-370

Size and shape description of commercially available polyethylene particles for in vitro and in vivo experiments;Größe und form kommerziell erhältlicher polyethylenpartikel für in-vitro- und in-vivo-versuche

Author keywords

Arthroplasty; Morphologic analysis; Osteolysis; Particles; Polyethylene; Size analysis

Indexed keywords

POLYETHYLENE; BIOMATERIAL; MICROSPHERE;

EID: 3042796059     PISSN: 00443220     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2004-822589     Document Type: Article
Times cited : (29)

References (31)
  • 1
    • 0032895351 scopus 로고    scopus 로고
    • Studies of host response to orthopedic implants and biomaterials
    • Santavirta S et al. Studies of host response to orthopedic implants and biomaterials. J Long Term Eff Med Implants 1999; 9: 67-76
    • (1999) J Long Term Eff Med Implants , vol.9 , pp. 67-76
    • Santavirta, S.1
  • 2
    • 0033781825 scopus 로고    scopus 로고
    • Alumina ceramic bearings for hip endoprostheses: The Austrian experiences
    • Böhler M, Plenk H Jr, Salzer M. Alumina ceramic bearings for hip endoprostheses: the Austrian experiences. Clin Orthop 2000; 379: 85-93
    • (2000) Clin Orthop , vol.379 , pp. 85-93
    • Böhler, M.1    Plenk Jr., H.2    Salzer, M.3
  • 3
    • 0025222261 scopus 로고
    • Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles
    • Willert HG, Bertram H, Buchhorn GH. Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop 1990; 258: 95-107
    • (1990) Clin Orthop , vol.258 , pp. 95-107
    • Willert, H.G.1    Bertram, H.2    Buchhorn, G.H.3
  • 4
    • 0025068079 scopus 로고
    • The cause of loosening in cemented hip joint prostheses. Light and electron microscopy study and laser microprobe mass analysis
    • Bos I, Lindner B, Seydel U, Johannisson R, Dorre E, Henssge J, Lohrs U. The cause of loosening in cemented hip joint prostheses. Light and electron microscopy study and laser microprobe mass analysis. Z Orthop Ihre Grenzgeb 1990; 128: 73-82
    • (1990) Z Orthop Ihre Grenzgeb , vol.128 , pp. 73-82
    • Bos, I.1    Lindner, B.2    Seydel, U.3    Johannisson, R.4    Dorre, E.5    Henssge, J.6    Lohrs, U.7
  • 5
    • 0026252968 scopus 로고
    • Differences in polyethylene wear in hip joint prostheses with ceramic- and with metal-polyethylene combination of the articulation surfaces - A study of surgical and of autopsy materials
    • Bos I, Meeuwssen E, Henssge EJ, Lohrs U. Differences in polyethylene wear in hip joint prostheses with ceramic- and with metal-polyethylene combination of the articulation surfaces - a study of surgical and of autopsy materials. Z Orthop Ihre Grenzgeb 1991; 129: 507-515
    • (1991) Z Orthop Ihre Grenzgeb , vol.129 , pp. 507-515
    • Bos, I.1    Meeuwssen, E.2    Henssge, E.J.3    Lohrs, U.4
  • 6
    • 0028877373 scopus 로고
    • Histological and morphometric studies of femurs with stable hip joint replacement. An autopsy study with special reference to factors leading to late loosening
    • Bos I, Berner J, Diebold J, Lohrs U. Histological and morphometric studies of femurs with stable hip joint replacement. An autopsy study with special reference to factors leading to late loosening. Z Orthop Ihre Grenzgeb 1995; 133: 460-466
    • (1995) Z Orthop Ihre Grenzgeb , vol.133 , pp. 460-466
    • Bos, I.1    Berner, J.2    Diebold, J.3    Lohrs, U.4
  • 7
    • 0034352247 scopus 로고    scopus 로고
    • Polyethylene content and cell size of foreign body giant cells in aseptic hip prosthesis loosening - A histomorphometric study
    • von Knoch M, Plotz G, Prymka M, Fortsch M, von Knoch F. Polyethylene content and cell size of foreign body giant cells in aseptic hip prosthesis loosening - a histomorphometric study. Z Orthop Ihre Grenzgeb 2000; 138: 522-525
    • (2000) Z Orthop Ihre Grenzgeb , vol.138 , pp. 522-525
    • Von Knoch, M.1    Plotz, G.2    Prymka, M.3    Fortsch, M.4    Von Knoch, F.5
  • 8
    • 0036191045 scopus 로고    scopus 로고
    • Cytokine profile of a human bone marrow cell culture on exposure to titanium-aluminium-vanadium particles
    • Wilke A, Endres S, Griss P, Herz U. Cytokine profile of a human bone marrow cell culture on exposure to titanium-aluminium-vanadium particles. Z Orthop Ihre Grenzgeb 2002; 140: 83-89
    • (2002) Z Orthop Ihre Grenzgeb , vol.140 , pp. 83-89
    • Wilke, A.1    Endres, S.2    Griss, P.3    Herz, U.4
  • 10
    • 7844225538 scopus 로고    scopus 로고
    • Prosthesis-bone interface
    • Plenk H Jr. Prosthesis-bone interface. J Biomed Mater Res 1998; 43: 350-355
    • (1998) J Biomed Mater Res , vol.43 , pp. 350-355
    • Plenk Jr., H.1
  • 12
    • 0033628937 scopus 로고    scopus 로고
    • Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers. Part H
    • Ingham E, Fisher J. Biological reactions to wear debris in total joint replacement. Proceedings of the Institution of Mechanical Engineers. Part H. J Eng Med 2000; 214: 21-37
    • (2000) J Eng Med , vol.214 , pp. 21-37
    • Ingham, E.1    Fisher, J.2
  • 14
    • 3042745013 scopus 로고    scopus 로고
    • Response of human macrophages to challenge with polyethylene wear debris harvested during revision arthroplasty
    • Lausanne, Switzerland
    • Barden B, Ding Y, Saxler G, Loer F. Response of human macrophages to challenge with polyethylene wear debris harvested during revision arthroplasty. Annual Meeting European Orthopaedic Research Society EORS, Lausanne, Switzerland 2002
    • (2002) Annual Meeting European Orthopaedic Research Society EORS
    • Barden, B.1    Ding, Y.2    Saxler, G.3    Loer, F.4
  • 15
    • 11744335821 scopus 로고    scopus 로고
    • A new screening method designed for wear analysis of bearing surfaces used in total hip arthroplasty
    • Jacobs J, Cendrowska T, Speiser P (eds). ASTM STP 1346. American Society for Testing Materials
    • Pienkowski D, Nassutt R, Lampe F, Schneider E, Morlock MM. A new screening method designed for wear analysis of bearing surfaces used in total hip arthroplasty In: Jacobs J, Cendrowska T, Speiser P (eds). Alternative bearing surfaces in total joint replacement. ASTM STP 1346. American Society for Testing Materials 1998; 30-43
    • (1998) Alternative Bearing Surfaces in Total Joint Replacement , pp. 30-43
    • Pienkowski, D.1    Nassutt, R.2    Lampe, F.3    Schneider, E.4    Morlock, M.M.5
  • 17
    • 11744335821 scopus 로고    scopus 로고
    • A new screening method designed for wear analysis of bearing surfaces used in total hip arthroplasty
    • Jacobs J, Cendrowska T, Speiser P (eds). ASTM STP 1346. American Society for Testing Materials
    • Wimmer MA, Nassutt R, Lampe F, Schneider E, Morlock MM. A new screening method designed for wear analysis of bearing surfaces used in total hip arthroplasty. In: Jacobs J, Cendrowska T, Speiser P (eds). Alternative Bearing Surfaces in Total Joint Replacement. ASTM STP 1346. American Society for Testing Materials 1998; 30-43
    • (1998) Alternative Bearing Surfaces in Total Joint Replacement , pp. 30-43
    • Wimmer, M.A.1    Nassutt, R.2    Lampe, F.3    Schneider, E.4    Morlock, M.M.5
  • 19
    • 0035443878 scopus 로고    scopus 로고
    • Size independent morphological description of polyethylene particles
    • Sprecher C, Wimmer MA. Size independent morphological description of polyethylene particles. J Biomech 2001; 34: 71
    • (2001) J Biomech , vol.34 , pp. 71
    • Sprecher, C.1    Wimmer, M.A.2
  • 20
    • 79951809366 scopus 로고    scopus 로고
    • Generalized size and shape description of UHMWPE wear debris - A Comparison of Cross-linked, Enhanced Fused, and Standard Polyethylene Particles
    • Kurtz SM, Gsell R, Martell J (eds). ASTM STP 1445. ASTM International, West Conshohocken, PA
    • Sprecher C, Schneider E, Wimmer MA. Generalized size and shape description of UHMWPE wear debris - A Comparison of Cross-linked, Enhanced Fused, and Standard Polyethylene Particles. In: Kurtz SM, Gsell R, Martell J (eds). Crosslinked and Thermally Treated Ultra-High Molecular Weight Polyethylene for Joint Replacements. ASTM STP 1445. ASTM International, West Conshohocken, PA 2003
    • (2003) Crosslinked and Thermally Treated Ultra-High Molecular Weight Polyethylene for Joint Replacements
    • Sprecher, C.1    Schneider, E.2    Wimmer, M.A.3
  • 22
    • 0035232592 scopus 로고    scopus 로고
    • Hip simulator wear testing according to the newly introduced standard ISO 14242
    • Kaddick C, Wimmer MA. Hip simulator wear testing according to the newly introduced standard ISO 14242. Proc Instn Mech Engrs 2001; 215: 429-442
    • (2001) Proc Instn Mech Engrs , vol.215 , pp. 429-442
    • Kaddick, C.1    Wimmer, M.A.2
  • 25
    • 0034906260 scopus 로고    scopus 로고
    • Transmission electron microscopy of intracellular particles of polyethylene from joint replacement prostheses: Size distribution and cellular response
    • Benz EB, Federman M, Godleski JJ, Bierbaum BE, Thornhill TS, Spector M. Transmission electron microscopy of intracellular particles of polyethylene from joint replacement prostheses: size distribution and cellular response. Biomat 2001; 22: 2835-2842
    • (2001) Biomat , vol.22 , pp. 2835-2842
    • Benz, E.B.1    Federman, M.2    Godleski, J.J.3    Bierbaum, B.E.4    Thornhill, T.S.5    Spector, M.6
  • 29
    • 0036116447 scopus 로고    scopus 로고
    • Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses
    • Endo M, Tipper JL, Barton DC, Stone MH, Ingham E, Fisher J. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses. Proc Inst Mech Eng [H] 2002; 216: 111-122
    • (2002) Proc Inst Mech Eng [H] , vol.216 , pp. 111-122
    • Endo, M.1    Tipper, J.L.2    Barton, D.C.3    Stone, M.H.4    Ingham, E.5    Fisher, J.6
  • 30
    • 0033814272 scopus 로고    scopus 로고
    • Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles
    • Green TR, Fisher J, Matthews JB, Stone MH, Ingham E. Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. J Biomed Mater Res 2000; 53: 490-497
    • (2000) J Biomed Mater Res , vol.53 , pp. 490-497
    • Green, T.R.1    Fisher, J.2    Matthews, J.B.3    Stone, M.H.4    Ingham, E.5
  • 31
    • 0742284135 scopus 로고    scopus 로고
    • The effectiveness of commercially available polyethylene versus titanium particles in inducing osteolysis in murine calvaria
    • von Knoch M, Jewison DE, Sibonga JD, Sprecher C, Morrey BF, Löer F, Berry DJ, Scully SP. The effectiveness of commercially available polyethylene versus titanium particles in inducing osteolysis in murine calvaria. J Orthop Res 2004; 22(2): 237-243
    • (2004) J Orthop Res , vol.22 , Issue.2 , pp. 237-243
    • Von Knoch, M.1    Jewison, D.E.2    Sibonga, J.D.3    Sprecher, C.4    Morrey, B.F.5    Löer, F.6    Berry, D.J.7    Scully, S.P.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.