메뉴 건너뛰기




Volumn 6, Issue 4, 2004, Pages 60-68

Monte Carlo simulation of complex radiotherapy treatments

Author keywords

[No Author keywords available]

Indexed keywords

COLLIMATORS; CPU; INTENSITY MODULATED RADIOTHERAPY (IMRT); PARALLEL VIRTUAL MACHINES (PVM);

EID: 3042773855     PISSN: 15219615     EISSN: None     Source Type: Journal    
DOI: 10.1109/MCSE.2004.16     Document Type: Article
Times cited : (16)

References (20)
  • 3
    • 0037150009 scopus 로고    scopus 로고
    • A monte carlo dose calculation tool for radio-therapy treatment planning
    • J.S. Li et al., "A Monte Carlo Dose Calculation Tool for Radio-therapy Treatment Planning," Physics in Medicine and Biology, vol. 47, no. 10, 2002, pp. 1671-1689.
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.10 , pp. 1671-1689
    • Li, J.S.1
  • 4
    • 0025730909 scopus 로고
    • Monte carlo techniques in medical radiation physics
    • July
    • P. Andreo, "Monte Carlo Techniques in Medical Radiation Physics," Physics in Medicine and Biology, vol. 36, July 1991, pp. 861-920.
    • (1991) Physics in Medicine and Biology , vol.36 , pp. 861-920
    • Andreo, P.1
  • 5
    • 0030945205 scopus 로고    scopus 로고
    • Accurate characterisation of monte carlo calculated electron beams for radiotherapy
    • C.M. Ma et al., "Accurate Characterisation of Monte Carlo Calculated Electron Beams for Radiotherapy," Medical Physics, vol. 24, no. 3, 1997, pp. 401-416.
    • (1997) Medical Physics , vol.24 , Issue.3 , pp. 401-416
    • Ma, C.M.1
  • 6
    • 0026689145 scopus 로고
    • A standard timing bench-mark for EGS4 monte carlo calculations
    • A.F. Bielajew and D.W.O. Rogers, "A Standard Timing Bench-mark for EGS4 Monte Carlo Calculations," Medical Physics, vol. 19, no. 2, 1992, pp. 303-304.
    • (1992) Medical Physics , vol.19 , Issue.2 , pp. 303-304
    • Bielajew, A.F.1    Rogers, D.W.O.2
  • 7
    • 0345701465 scopus 로고    scopus 로고
    • Routine IMRT verification by means of an automatic MC simulation system
    • A. Leal, et al., "Routine IMRT Verification By Means of an Automatic MC Simulation System," Int'l J. Radiology, Oncology, Biology and Physics, vol. 56, no. 1, pp. 58-68.
    • Int'l J. Radiology, Oncology, Biology and Physics , vol.56 , Issue.1 , pp. 58-68
    • Leal, A.1
  • 8
    • 0037361636 scopus 로고    scopus 로고
    • Investigation of radiosurgical beam profiles using MC method
    • M. Perucha et al., "Investigation of Radiosurgical Beam Profiles Using MC Method, Medical Dosimetry, vol. 28, no. 1, pp. 1-6.
    • Medical Dosimetry , vol.28 , Issue.1 , pp. 1-6
    • Perucha, M.1
  • 9
    • 0024087818 scopus 로고
    • Trade-off in granularity and parallelization for a monte carlo shower code (EGS4)
    • K. Miura and R.G. Babb, "Trade-Off in Granularity and Parallelization for a Monte Carlo Shower Code (EGS4)," Parallel Computing, vol. 8, nos. 1-3, 1987, pp. 91-100.
    • (1987) Parallel Computing , vol.8 , Issue.1-3 , pp. 91-100
    • Miura, K.1    Babb, R.G.2
  • 10
    • 0028468046 scopus 로고
    • Implementation of a monte carlo code on a parallel computer system
    • C.M. Ma, "Implementation of a Monte Carlo Code on a Parallel Computer System," Parallel Computing, vol. 20, no. 7, 1994, pp. 991-1005.
    • (1994) Parallel Computing , vol.20 , Issue.7 , pp. 991-1005
    • Ma, C.M.1
  • 11
    • 84888958887 scopus 로고    scopus 로고
    • Distributed processing for CPU time optimization
    • A. Leal et al., "Distributed Processing for CPU Time Optimization," Physica Medica, vol. 17, no. 4, pp. 84-86.
    • Physica Medica , vol.17 , Issue.4 , pp. 84-86
    • Leal, A.1
  • 14
    • 0004279418 scopus 로고    scopus 로고
    • Nat'l Research Council of Canada
    • BEAM Users Manual, Nat'l Research Council of Canada, 1997.
    • (1997) BEAM Users Manual
  • 15
    • 0029035150 scopus 로고
    • BEAM: A monte carlo code to simulate radiotherapy treatment units
    • D.W.O. Rogers et al., "BEAM: A Monte Carlo Code to Simulate Radiotherapy Treatment Units," Medical Physics, vol. 22, no. 5, 1995, pp. 503-524.
    • (1995) Medical Physics , vol.22 , Issue.5 , pp. 503-524
    • Rogers, D.W.O.1
  • 16
    • 0004279421 scopus 로고    scopus 로고
    • Nat'l Research Council of Canada Report
    • DOSXYZ Users Manual, Nat'l Research Council of Canada Report, 1998.
    • (1998) DOSXYZ Users Manual
  • 17
    • 0023138959 scopus 로고
    • PRESTA: The parameter reduced electron-step transport algorithm for electron monte carlo transport
    • A.F. Bielajew and D.W.O. Rogers, "PRESTA: The Parameter Reduced Electron-Step Transport Algorithm for Electron Monte Carlo Transport," Nuclear Instruments and Methods, vol. B18, 1987, pp. 165-181.
    • (1987) Nuclear Instruments and Methods , vol.B18 , pp. 165-181
    • Bielajew, A.F.1    Rogers, D.W.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.