Volumn 26, Issue 3, 2004, Pages 327-332

Evaluation of methods of archwire ligation on frictional resistance

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL ALLOY; ELASTOMER; MOLYBDENUM; STAINLESS STEEL; TITANIUM;

EID: 3042760489     PISSN: 01415387     EISSN: None     Source Type: Journal    
DOI: 10.1093/ejo/26.3.327     Document Type: Article
Times cited : (71)

References (28)
  • 5
    • 0028379714 scopus 로고
    • A comparison of the frictional characteristics of five initial alignment wires and stainless steel brackets at three bracket to wire angulations - An in vitro study
    • Dickson J A, Jones S P, Davies E H 1994 A comparison of the frictional characteristics of five initial alignment wires and stainless steel brackets at three bracket to wire angulations - an in vitro study. British Journal of Orthodontics 21: 15-22
    • (1994) British Journal of Orthodontics , vol.21 , pp. 15-22
    • Dickson, J.A.1    Jones, S.P.2    Davies, E.H.3
  • 7
    • 0028541889 scopus 로고
    • A study of frictional forces between orthodontic brackets and arch wires
    • Downing A, McCabe J F, Gordon P H 1994 A study of frictional forces between orthodontic brackets and arch wires. British Journal of Orthodontics 21: 349-357
    • (1994) British Journal of Orthodontics , vol.21 , pp. 349-357
    • Downing, A.1    McCabe, J.F.2    Gordon, P.H.3
  • 8
    • 0029243854 scopus 로고
    • The effect of artificial saliva on the frictional forces between orthodontic brackets and archwires
    • Downing A, McCabe J F, Gordon P H 1995 The effect of artificial saliva on the frictional forces between orthodontic brackets and archwires. British Journal of Orthodontics 22: 41-46
    • (1995) British Journal of Orthodontics , vol.22 , pp. 41-46
    • Downing, A.1    McCabe, J.F.2    Gordon, P.H.3
  • 9
    • 0029298409 scopus 로고
    • The ex vivo effect of ligation technique on the static frictional resistance of stainless steel brackets and archwires
    • Edwards G D, Davies E H, Jones S P 1995 The ex vivo effect of ligation technique on the static frictional resistance of stainless steel brackets and archwires. British Journal of Orthodontics 22: 145-153
    • (1995) British Journal of Orthodontics , vol.22 , pp. 145-153
    • Edwards, G.D.1    Davies, E.H.2    Jones, S.P.3
  • 10
    • 0019250102 scopus 로고
    • A comparative study of frictional resistances between orthodontic bracket and arch wire
    • Frank C A, Nikolai R J 1980 A comparative study of frictional resistances between orthodontic bracket and arch wire. American Journal of Orthodontics 78: 593-609
    • (1980) American Journal of Orthodontics , vol.78 , pp. 593-609
    • Frank, C.A.1    Nikolai, R.J.2
  • 14
    • 0024698081 scopus 로고
    • Effects of sliding velocity on the coefficients of friction in a model orthodontic system
    • Kusy R P, Whitley J Q 1989 Effects of sliding velocity on the coefficients of friction in a model orthodontic system. Dental Materials 5: 235-240
    • (1989) Dental Materials , vol.5 , pp. 235-240
    • Kusy, R.P.1    Whitley, J.Q.2
  • 16
    • 0026269812 scopus 로고
    • Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states
    • Kusy R P, Whitley J Q, Prewitt M J 1991 Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states. Angle Orthodontist 61: 293-302
    • (1991) Angle Orthodontist , vol.61 , pp. 293-302
    • Kusy, R.P.1    Whitley, J.Q.2    Prewitt, M.J.3
  • 17
    • 0035379026 scopus 로고    scopus 로고
    • A model for evaluating friction during orthodontic tooth movement
    • Loftus B P, Årtun J 2001 A model for evaluating friction during orthodontic tooth movement. European Journal of Orthodontics 23: 253-261
    • (2001) European Journal of Orthodontics , vol.23 , pp. 253-261
    • Loftus, B.P.1    Årtun, J.2
  • 18
    • 0024625539 scopus 로고
    • The transition from standard edgewise to preadjusted appliance systems
    • McLaughlin R P, Bennett J C 1989 The transition from standard edgewise to preadjusted appliance systems. Journal of Clinical Orthodontics 23: 142-153
    • (1989) Journal of Clinical Orthodontics , vol.23 , pp. 142-153
    • McLaughlin, R.P.1    Bennett, J.C.2
  • 20
    • 0020131092 scopus 로고
    • A comparison of friction resistance for Nitinol and stainless steel wire in edgewise brackets
    • Peterson L, Spencer R, Andreasen G 1982 A comparison of friction resistance for Nitinol and stainless steel wire in edgewise brackets. Quintessence International 13: 563-571
    • (1982) Quintessence International , vol.13 , pp. 563-571
    • Peterson, L.1    Spencer, R.2    Andreasen, G.3
  • 23
    • 0027685911 scopus 로고
    • A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation
    • Sims A P, Waters N E, Birnie D J, Pethybridge R J 1993 A comparison of the forces required to produce tooth movement in vitro using two self-ligating brackets and a pre-adjusted bracket employing two types of ligation. European Journal of Orthodontics 15: 377-385
    • (1993) European Journal of Orthodontics , vol.15 , pp. 377-385
    • Sims, A.P.1    Waters, N.E.2    Birnie, D.J.3    Pethybridge, R.J.4
  • 24
    • 0028545408 scopus 로고
    • A comparison of the forces required to produce tooth movement ex vivo through three types of pre-adjusted brackets when subjected to determined tip or torque values
    • Sims A P, Waters N E, Birnie D J 1994 A comparison of the forces required to produce tooth movement ex vivo through three types of pre-adjusted brackets when subjected to determined tip or torque values. British Journal of Orthodontics 21: 367-373
    • (1994) British Journal of Orthodontics , vol.21 , pp. 367-373
    • Sims, A.P.1    Waters, N.E.2    Birnie, D.J.3
  • 25
    • 0026264005 scopus 로고
    • Wire friction from ceramic brackets during simulated canine retraction
    • Tanne K, Matsubara S, Shibaguchi T, Sakuda M 1991 Wire friction from ceramic brackets during simulated canine retraction. Angle Orthodontist 61: 285-290
    • (1991) Angle Orthodontist , vol.61 , pp. 285-290
    • Tanne, K.1    Matsubara, S.2    Shibaguchi, T.3    Sakuda, M.4
  • 26
    • 0029679580 scopus 로고    scopus 로고
    • Frictional resistance between orthodontic brackets and archwires in the buccal segments
    • Taylor N G, Ison K 1996 Frictional resistance between orthodontic brackets and archwires in the buccal segments. Angle Orthodontist 66: 215-222
    • (1996) Angle Orthodontist , vol.66 , pp. 215-222
    • Taylor, N.G.1    Ison, K.2
  • 27
    • 0032193834 scopus 로고    scopus 로고
    • A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures
    • Thomas S, Sherriff M, Birnie D 1998 A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures. European Journal of Orthodontics 20: 589-596
    • (1998) European Journal of Orthodontics , vol.20 , pp. 589-596
    • Thomas, S.1    Sherriff, M.2    Birnie, D.3