메뉴 건너뛰기




Volumn 28, Issue 7, 2004, Pages 639-648

Computational fluid dynamics-analysis of the Niagara hemodialysis catheter in a right heart model

Author keywords

Computational fluid dynamics; Dialysis catheter performance; Recirculation percentage; Right atrium model; Shear rate; Side holes

Indexed keywords

CATHETERS; DIALYSIS; SHEAR DEFORMATION; SHEAR FLOW;

EID: 3042725349     PISSN: 0160564X     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2004.07371.x     Document Type: Article
Times cited : (34)

References (30)
  • 1
    • 0027439331 scopus 로고
    • Late referral to maintenance dialysis - Detrimental consequences
    • Jungers P, Zingraff J, Albouze G, et al. Late referral to maintenance dialysis - detrimental consequences. Nephrol Dial Transplant 1993;8:1089-93.
    • (1993) Nephrol Dial Transplant , vol.8 , pp. 1089-1093
    • Jungers, P.1    Zingraff, J.2    Albouze, G.3
  • 2
    • 17144451047 scopus 로고    scopus 로고
    • First hemodialysis access selection varies with patient acuity
    • Friedman AL, Walworth C, Meehan C, et al. First hemodialysis access selection varies with patient acuity. Adv Ren Replace Ther 2000;7:4-10.
    • (2000) Adv Ren Replace Ther , vol.7 , pp. 4-10
    • Friedman, A.L.1    Walworth, C.2    Meehan, C.3
  • 3
    • 0033918329 scopus 로고    scopus 로고
    • Determinants of type and timing of initial permanent hemodialysis vascular access
    • Stehman-Breen CO, Sherrard DJ, Gillen D, Caps M. Determinants of type and timing of initial permanent hemodialysis vascular access. Kidney Int 2000;57:639-45.
    • (2000) Kidney Int , vol.57 , pp. 639-645
    • Stehman-Breen, C.O.1    Sherrard, D.J.2    Gillen, D.3    Caps, M.4
  • 4
    • 0033960109 scopus 로고    scopus 로고
    • Use of standardized ratios to examine variability in hemodialysis vascular access across facilities
    • Sehgal AR, Silver MR, Covinsky KE, Coffin R, Cain JA. Use of standardized ratios to examine variability in hemodialysis vascular access across facilities. Am J Kidney Dis 2000;35:275-81.
    • (2000) Am J Kidney Dis , vol.35 , pp. 275-281
    • Sehgal, A.R.1    Silver, M.R.2    Covinsky, K.E.3    Coffin, R.4    Cain, J.A.5
  • 5
    • 3042716527 scopus 로고    scopus 로고
    • Dialysis access: Past, present and future
    • Akoh JA, Hakim NS, eds. London: Imperial College Press
    • Akoh JA. Dialysis access: past, present and future. In: Akoh JA, Hakim NS, eds. Dialysis Access - Current Practice, 1th Edition. London: Imperial College Press, 2001;1-21.
    • (2001) Dialysis Access - Current Practice, 1th Edition , pp. 1-21
    • Akoh, J.A.1
  • 6
    • 0021783946 scopus 로고
    • A mechanistic analysis of the National Cooperative Dialysis Study (NCDS)
    • Gotch FA, Sargent JA. A mechanistic analysis of the National Cooperative Dialysis Study (NCDS). Kidney Int 1985;28:526-34.
    • (1985) Kidney Int , vol.28 , pp. 526-534
    • Gotch, F.A.1    Sargent, J.A.2
  • 7
    • 0035523894 scopus 로고    scopus 로고
    • Catheter performance
    • Depner TA. Catheter performance. Sem Dial 2001;14:425-31.
    • (2001) Sem Dial , vol.14 , pp. 425-431
    • Depner, T.A.1
  • 8
    • 0003309626 scopus 로고
    • Mechanical hemolysis in flowing blood
    • Fung YC, ed. Englewood Cliffs, NJ: Prentice-Hall
    • Blackshear PL. Mechanical hemolysis in flowing blood. In: Fung YC, ed. Biomechanics. Its Foundation and Objectives. Englewood Cliffs, NJ: Prentice-Hall, 1972;501.
    • (1972) Biomechanics. Its Foundation and Objectives , pp. 501
    • Blackshear, P.L.1
  • 9
    • 0021685904 scopus 로고
    • Human red blood-cell hemolysis in a turbulent shear-flow - Contribution of Reynolds shear stresses
    • Sallam AM, Hwang NHC. Human red blood-cell hemolysis in a turbulent shear-flow - contribution of Reynolds shear stresses. Biorheology 1984;21:783-97.
    • (1984) Biorheology , vol.21 , pp. 783-797
    • Sallam, A.M.1    Hwang, N.H.C.2
  • 10
    • 0025082325 scopus 로고
    • Estimation of shear stress-related blood damage in heart-valve prostheses - In vitro comparison of 25 aortic valves
    • Giersiepen M, Wurzinger LJ, Opitz R, Reul H. Estimation of shear stress-related blood damage in heart-valve prostheses - in vitro comparison of 25 aortic valves. Int J Artif Organs 1990;13:300-6.
    • (1990) Int J Artif Organs , vol.13 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.J.2    Opitz, R.3    Reul, H.4
  • 11
    • 0022318434 scopus 로고
    • Evaluation of central venous catheter thrombogenicity
    • Borow M, Crowley JG. Evaluation of central venous catheter thrombogenicity. Acta Anaesthesiol Scand 1985;29:59-64.
    • (1985) Acta Anaesthesiol Scand , vol.29 , pp. 59-64
    • Borow, M.1    Crowley, J.G.2
  • 12
    • 0030271406 scopus 로고    scopus 로고
    • Influence of wall shear rate on parameters of blood compatibility of intravascular catheters
    • Rhodes NP, Kumary TV, Williams DF. Influence of wall shear rate on parameters of blood compatibility of intravascular catheters. Biomaterials 1996;17:1995-2002.
    • (1996) Biomaterials , vol.17 , pp. 1995-2002
    • Rhodes, N.P.1    Kumary, T.V.2    Williams, D.F.3
  • 13
    • 0034326939 scopus 로고    scopus 로고
    • Formation of occlusive platelet aggregates in whole blood caused by low concentrations of ADP
    • Hall MW, Goodman PD, Solen KA, Mohammad SF. Formation of occlusive platelet aggregates in whole blood caused by low concentrations of ADP. ASAIO J 2000;46:693-5.
    • (2000) ASAIO J , vol.46 , pp. 693-695
    • Hall, M.W.1    Goodman, P.D.2    Solen, K.A.3    Mohammad, S.F.4
  • 14
    • 0034753515 scopus 로고    scopus 로고
    • Side holes at the tip of chronic hemodialysis catheters are harmful
    • Twardowski J, Moore HL. Side holes at the tip of chronic hemodialysis catheters are harmful. J Vasc Access 2001;2:8-16.
    • (2001) J Vasc Access , vol.2 , pp. 8-16
    • Twardowski, J.1    Moore, H.L.2
  • 15
    • 0033622807 scopus 로고    scopus 로고
    • Study on blood constitutive parameters in different blood constitutive equations
    • Zhang JB, Kuang ZB. Study on blood constitutive parameters in different blood constitutive equations. J Biomech 2000;33:355-60.
    • (2000) J Biomech , vol.33 , pp. 355-360
    • Zhang, J.B.1    Kuang, Z.B.2
  • 17
    • 0036890484 scopus 로고    scopus 로고
    • Computational model of the fluid dynamics of a cannula inserted in a vessel: Incidence of the presence of side holes in blood flow
    • Grigioni M, Daniele C, Morbiducci U, et al. Computational model of the fluid dynamics of a cannula inserted in a vessel: incidence of the presence of side holes in blood flow. J Biomech 2002;35:1599-612.
    • (2002) J Biomech , vol.35 , pp. 1599-1612
    • Grigioni, M.1    Daniele, C.2    Morbiducci, U.3
  • 18
    • 0035985044 scopus 로고    scopus 로고
    • Computational fluid dynamics and vascular access
    • Krueger U, Zanow J, Scholz H. Computational fluid dynamics and vascular access. Artif Organs 2002;26:571-5.
    • (2002) Artif Organs , vol.26 , pp. 571-575
    • Krueger, U.1    Zanow, J.2    Scholz, H.3
  • 20
    • 0035522937 scopus 로고    scopus 로고
    • Chronic catheter placement
    • Work J. Chronic catheter placement. Semin Dial 2001;14:436-40.
    • (2001) Semin Dial , vol.14 , pp. 436-440
    • Work, J.1
  • 21
    • 0035228229 scopus 로고    scopus 로고
    • III-NKF-K/DOQI. Clinical practice guidelines for vascular access: Update 2000
    • III-NKF-K/DOQI. Clinical practice guidelines for vascular access: update 2000. Am J Kidney Dis 2001;37:137-81.
    • (2001) Am J Kidney Dis , vol.37 , pp. 137-181
  • 22
    • 0345337292 scopus 로고    scopus 로고
    • Computational blood flow modelling: Errors associated with reconstructing finite element models from magnetic resonance images
    • Moore JA, Steinman DA, Ethier CR. Computational blood flow modelling: errors associated with reconstructing finite element models from magnetic resonance images. J Biomech 1998;31:179-84.
    • (1998) J Biomech , vol.31 , pp. 179-184
    • Moore, J.A.1    Steinman, D.A.2    Ethier, C.R.3
  • 27
    • 0001844724 scopus 로고
    • Response of platelets to shear stress - A review
    • Gross DR, Hwang NHC, eds. Alphen aan den Rijn: Sijthoff and Noordhoff
    • Hellums JD, Hardwick RA. Response of platelets to shear stress - a review. In: Gross DR, Hwang NHC, eds. The Rheology of Blood Vessels and Associated Tissues. Alphen aan den Rijn: Sijthoff and Noordhoff, 1981;160-83.
    • (1981) The Rheology of Blood Vessels and Associated Tissues , pp. 160-183
    • Hellums, J.D.1    Hardwick, R.A.2
  • 28
    • 3042841030 scopus 로고
    • Mechanical trauma induced PMN leucocyte dysfunction
    • Gross DR, Hwang NHC, eds. Alphen aan den Rijn: Sijthoff & Noordhoff
    • McIntire LV, Martin RR. Mechanical trauma induced PMN leucocyte dysfunction. In: Gross DR, Hwang NHC, eds. The Rheology of Blood Vessels and Associated Tissues. Alphen aan den Rijn: Sijthoff & Noordhoff, 1981.
    • (1981) The Rheology of Blood Vessels and Associated Tissues
    • McIntire, L.V.1    Martin, R.R.2
  • 29
    • 0346059625 scopus 로고    scopus 로고
    • Blood flow and recirculation rates in tunneled hemodialysis catheters
    • Senecal L, Saint-Sauveur E, Leblanc M. Blood flow and recirculation rates in tunneled hemodialysis catheters. ASAIO J 2004;50:94-7.
    • (2004) ASAIO J , vol.50 , pp. 94-97
    • Senecal, L.1    Saint-Sauveur, E.2    Leblanc, M.3
  • 30
    • 0004149569 scopus 로고
    • Indianapolis: Lippincott Williams & Wilkins
    • Feigenbaum H. Echocardiography. Indianapolis: Lippincott Williams & Wilkins, 1994.
    • (1994) Echocardiography
    • Feigenbaum, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.