메뉴 건너뛰기




Volumn 11, Issue 7, 2004, Pages 729-734

Ventilation imaging of the lung: Comparison of hyperpolarized helium-3 MR imaging with Xe-133 scintigraphy

Author keywords

Chest MRI; hyperpolarized gas MRI; lung ventilation imaging; radionuclide imaging; Xe 133

Indexed keywords

HELIUM; XENON 133;

EID: 3042706443     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2004.04.001     Document Type: Article
Times cited : (36)

References (12)
  • 1
    • 0028814636 scopus 로고
    • MR imaging with hyperpolarized He-3 gas
    • Middleton H., Black R.D., Saam B., et al. MR imaging with hyperpolarized He-3 gas. Magn Reson Med. 33:1995;271-275
    • (1995) Magn Reson Med , vol.33 , pp. 271-275
    • Middleton, H.1    Black, R.D.2    Saam, B.3
  • 2
    • 10244222858 scopus 로고    scopus 로고
    • Normal and abnormal pulmonary ventilation: Visualization at hyperpolarized He-3 MR imaging
    • Kauczor H.U., Hofmann D., Kreitner K.F., et al. Normal and abnormal pulmonary ventilation visualization at hyperpolarized He-3 MR imaging. Radiology. 201:1996;564-568
    • (1996) Radiology , vol.201 , pp. 564-568
    • Kauczor, H.U.1    Hofmann, D.2    Kreitner, K.F.3
  • 3
    • 15844394269 scopus 로고    scopus 로고
    • In vivo He-3 MR images of guinea pig lungs
    • Black R.D., Middleton H.L., Cates G.D., et al. In vivo He-3 MR images of guinea pig lungs. Radiology. 199:1996;867-870
    • (1996) Radiology , vol.199 , pp. 867-870
    • Black, R.D.1    Middleton, H.L.2    Cates, G.D.3
  • 4
    • 8944220243 scopus 로고    scopus 로고
    • Human lung air spaces: Potential for MR imaging with hyperpolarized He-3
    • MacFall J.R., Charles H.C., Black R.D., et al. Human lung air spaces potential for MR imaging with hyperpolarized He-3. Radiology. 200:1996;553-558
    • (1996) Radiology , vol.200 , pp. 553-558
    • MacFall, J.R.1    Charles, H.C.2    Black, R.D.3
  • 5
    • 0031397685 scopus 로고    scopus 로고
    • 3He MR imaging: Preliminary clinical experience in 18 patients with and without lung disease
    • 3He MR imaging preliminary clinical experience in 18 patients with and without lung disease. J Magn Reson Imaging. 7:1997;538-543
    • (1997) J Magn Reson Imaging , vol.7 , pp. 538-543
    • Kauczor, H.U.1    Ebert, M.2    Kreitner, K.F.3
  • 8
    • 0032860064 scopus 로고    scopus 로고
    • 3He-enhanced and conventional proton MR imaging in the lung - Preliminary observations
    • 3He-enhanced and conventional proton MR imaging in the lung - preliminary observations. Radiology. 212:1999;885-889
    • (1999) Radiology , vol.212 , pp. 885-889
    • Donnelly, L.F.1    MacFall, J.R.2    McAdams, H.P.3
  • 9
    • 0032871921 scopus 로고    scopus 로고
    • Hyperpolarized 3He-enhanced MR imaging of lung transplant recipients: Preliminary results
    • McAdams H.P., Palmer S.M., Donnelly L.F., et al. Hyperpolarized 3He-enhanced MR imaging of lung transplant recipients preliminary results. AJR Am J Roentgenol. 173:1999;955-959
    • (1999) AJR Am J Roentgenol , vol.173 , pp. 955-959
    • McAdams, H.P.1    Palmer, S.M.2    Donnelly, L.F.3
  • 10
    • 0000596361 scopus 로고
    • Note on the sampling error of the difference between correlated proportions or percentages
    • McNemar Q. Note on the sampling error of the difference between correlated proportions or percentages. Psychometrika. 12:1947;153-157
    • (1947) Psychometrika , vol.12 , pp. 153-157
    • McNemar, Q.1
  • 12
    • 0035186450 scopus 로고    scopus 로고
    • Statistical issues in analysis of diagnostic imaging experiments with multiple observations per patient
    • Gonen M., Panageas K.S., Larson S. Statistical issues in analysis of diagnostic imaging experiments with multiple observations per patient. Radiology. 221:2001;763-767
    • (2001) Radiology , vol.221 , pp. 763-767
    • Gonen, M.1    Panageas, K.S.2    Larson, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.