메뉴 건너뛰기




Volumn 512, Issue , 2004, Pages 1-19

Estimation of viscosity profiles using velocimetry data from parallel flows of linearly viscous fluids: Application to microvascular haemodynamics

Author keywords

[No Author keywords available]

Indexed keywords

CAPILLARY TUBES; KINEMATICS; NEWTONIAN FLOW; RHEOLOGY; STEADY FLOW; THICKNESS CONTROL; VELOCITY MEASUREMENT; VISCOSITY;

EID: 3042701000     PISSN: 00221120     EISSN: None     Source Type: Journal    
DOI: 10.1017/S0022112004008766     Document Type: Article
Times cited : (58)

References (27)
  • 1
    • 0028295106 scopus 로고
    • Rheological and hemodynamic characteristics of red cells of mouse, rat and human
    • CHEN, D. & KAUL, D. K. 1994 Rheological and hemodynamic characteristics of red cells of mouse, rat and human. Biorheology 31, 103-113.
    • (1994) Biorheology , vol.31 , pp. 103-113
    • Chen, D.1    Kaul, D.K.2
  • 2
    • 0013873058 scopus 로고
    • Effects of hematocrit and plasma proteins on human blood rheology at low shear rates
    • CHIEN, S., USAMI, S., TAYLOR, H. M., LUNDBERG, J. L. & GREGERSEN, M. I. 1966 Effects of hematocrit and plasma proteins on human blood rheology at low shear rates. J. Appl. Physiol. 21, 81-87.
    • (1966) J. Appl. Physiol. , vol.21 , pp. 81-87
    • Chien, S.1    Usami, S.2    Taylor, H.M.3    Lundberg, J.L.4    Gregersen, M.I.5
  • 3
    • 0033291325 scopus 로고    scopus 로고
    • Viscometric, in, vitro, and in vivo blood viscosity relationships: How are they related?
    • COKELET, G. R. 1999 Viscometric, in, vitro, and in vivo blood viscosity relationships: how are they related? Biorheology 36,343-358.
    • (1999) Biorheology , vol.36 , pp. 343-358
    • Cokelet, G.R.1
  • 4
    • 0009048509 scopus 로고    scopus 로고
    • Blood flow in microvessels lined with a poroelastic wall layer
    • (ed J.-F. Thimus, Y. Abousleiman, A. H. -D. Cheng, O. Coussy and E. Detournay), Balkema, Rottderdam
    • DAMIANO, E. R. 1998 Blood flow in microvessels lined with a poroelastic wall layer. In Poromechanics (ed. J.-F. Thimus, Y. Abousleiman, A. H. -D. Cheng, O. Coussy & E. Detournay), pp. 403-408. Balkema, Rottderdam.
    • (1998) Poromechanics , pp. 403-408
    • Damiano, E.R.1
  • 5
    • 0030131210 scopus 로고    scopus 로고
    • Axisymmetric pressure-driven flow of rigid pellets through a cylindrical tube lined with a deformable porous wall layer
    • DAMIANO, E. R., DULING, B. R., LEY, K. & SKALAK, T. C. 1996 Axisymmetric pressure-driven flow of rigid pellets through a cylindrical tube lined with a deformable porous wall layer. J. Fluid Mech. 314, 163-189.
    • (1996) J. Fluid Mech. , vol.314 , pp. 163-189
    • Damiano, E.R.1    Duling, B.R.2    Ley, K.3    Skalak, T.C.4
  • 6
    • 1542377368 scopus 로고    scopus 로고
    • On the motion of a sphere in a Stokes flow parallel to a Brinkman half-space
    • DAMIANO, E. R., LONG, D. S., EL-KHATIB, F. H. & STACE, T. M. 2004 On the motion of a sphere in a Stokes flow parallel to a Brinkman half-space. J. Fluid Mech. 500, 75-101.
    • (2004) J. Fluid Mech. , vol.500 , pp. 75-101
    • Damiano, E.R.1    Long, D.S.2    El-Khatib, F.H.3    Stace, T.M.4
  • 7
    • 0036192834 scopus 로고    scopus 로고
    • A mechano-electrochemical model of radial deformation of the capillary glycocalyx
    • DAMIANO, E. R. & STACE, T. M. 2002 A mechano-electrochemical model of radial deformation of the capillary glycocalyx. Biophys. J. 82, 1153-1175.
    • (2002) Biophys. J. , vol.82 , pp. 1153-1175
    • Damiano, E.R.1    Stace, T.M.2
  • 8
    • 0002497224 scopus 로고
    • A slow motion of viscous liquid caused by the rotation of a solid sphere
    • DEAN, W. R. & O'NEILL, M. E. 1963 A slow motion of viscous liquid caused by the rotation of a solid sphere. Mathematika 10, 13-24.
    • (1963) Mathematika , vol.10 , pp. 13-24
    • Dean, W.R.1    O'Neill, M.E.2
  • 9
    • 0023260201 scopus 로고
    • Microvessel hematocrit: Measurement and implications for capillary oxygen transport
    • DESJARDINS, C. & DULING, B. P. 1987 Microvessel hematocrit: measurement and implications for capillary oxygen transport. Am. J. Physiol. 252, H494-H503.
    • (1987) Am. J. Physiol. , vol.252
    • Desjardins, C.1    Duling, B.P.2
  • 10
    • 0042420635 scopus 로고    scopus 로고
    • Linear and nonlinear analyses of pulsatile blood flow in a cylindrical tube
    • EL-KHATIB, F. H. & DAMIANO, E. R. 2003 Linear and nonlinear analyses of pulsatile blood flow in a cylindrical tube. Biorheology 40, 503-522.
    • (2003) Biorheology , vol.40 , pp. 503-522
    • El-Khatib, F.H.1    Damiano, E.R.2
  • 11
    • 0034634847 scopus 로고    scopus 로고
    • Lubrication theory in highly compressible porous media: The mechanics of skiing, from red cells to humans
    • FENG, J. & WEINBAUM, S. 2000 Lubrication theory in highly compressible porous media: the mechanics of skiing, from red cells to humans. J. Fluid Mech. 422, 281-317.
    • (2000) J. Fluid Mech. , vol.422 , pp. 281-317
    • Feng, J.1    Weinbaum, S.2
  • 12
    • 0008884532 scopus 로고
    • Slow viscous motion of a sphere parallel to a plane wall-II Couette flow
    • GOLDMAN, A. J., COX, R. G. & BRENNER, H. 1967 Slow viscous motion of a sphere parallel to a plane wall-II Couette flow. Chem. Engng Sci. 22, 653-660.
    • (1967) Chem. Engng Sci. , vol.22 , pp. 653-660
    • Goldman, A.J.1    Cox, R.G.2    Brenner, H.3
  • 13
    • 0018076820 scopus 로고
    • The distribution of blood rheological parameters in the microvasculature of cat mesentery
    • LIPOWSKY, H. H., KOVALCHECK, S. & ZWEIFACH, B. W. 1978 The distribution of blood rheological parameters in the microvasculature of cat mesentery. Circ. Res. 43, 738-749.
    • (1978) Circ. Res. , vol.43 , pp. 738-749
    • Lipowsky, H.H.1    Kovalcheck, S.2    Zweifach, B.W.3
  • 14
    • 0018976258 scopus 로고
    • In vivo measurements of 'apparent viscosity' and microvessel hematocrit in the mesentery of the cat
    • LIPOWSKY, H. H., USAMI, S. & CHIEN, S. 1980 In vivo measurements of 'apparent viscosity' and microvessel hematocrit in the mesentery of the cat. Microvasc. Res. 19, 297-319.
    • (1980) Microvasc. Res. , vol.19 , pp. 297-319
    • Lipowsky, H.H.1    Usami, S.2    Chien, S.3
  • 15
    • 3042791439 scopus 로고    scopus 로고
    • Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution
    • LONG, D. S., SMITH, M. L., PRIES, A. R., LEY, K. & DAMIANO, E. R. 2004 Microviscometry reveals reduced blood viscosity and altered shear rate and shear stress profiles in microvessels after hemodilution. Proc. Natl Acad. Sci. USA 101, 10060-10065.
    • (2004) Proc. Natl Acad. Sci. USA , vol.101 , pp. 10060-10065
    • Long, D.S.1    Smith, M.L.2    Pries, A.R.3    Ley, K.4    Damiano, E.R.5
  • 16
    • 0024796927 scopus 로고
    • Prediction of oxygen transport rates in blood flowing in large capillaries
    • NAIR, P. K., HELLUMS, J. D. & OLSON, J.S. 1989 Prediction of oxygen transport rates in blood flowing in large capillaries. Microvasc. Res. 38, 269-285.
    • (1989) Microvasc. Res. , vol.38 , pp. 269-285
    • Nair, P.K.1    Hellums, J.D.2    Olson, J.S.3
  • 17
    • 84916072476 scopus 로고
    • A slow motion of viscous liquid caused by a slowly moving solid sphere
    • O'NEILL, M. E. 1964 A slow motion of viscous liquid caused by a slowly moving solid sphere. Mathematika 11, 67-74.
    • (1964) Mathematika , vol.11 , pp. 67-74
    • O'Neill, M.E.1
  • 18
    • 0027089966 scopus 로고
    • Blood viscosity in tube flow: Dependence on diameter
    • PRIES, A. R., NEUHAUS, D. & GAEHTGENS, P. 1992 Blood viscosity in tube flow: dependence on diameter. Am. J. Physiol. 263, H1770-H1778.
    • (1992) Am. J. Physiol. , vol.263
    • Pries, A.R.1    Neuhaus, D.2    Gaehtgens, P.3
  • 22
    • 0029447751 scopus 로고
    • Mechanics of blood flow in the microcirculation
    • (ed. C. P. Ellington and T. J. Pedley), Company of Biologists, Cambridge
    • SECOMB, T. W. 1995 Mechanics of blood flow in the microcirculation. In Biological Fluid Dynamics (ed. C. P. Ellington & T. J. Pedley), pp. 305-321. Company of Biologists, Cambridge.
    • (1995) Biological Fluid Dynamics , pp. 305-321
    • Secomb, T.W.1
  • 23
    • 0035738371 scopus 로고    scopus 로고
    • A two-phase model for flow of blood in narrow tubes with increased effective viscosity near the wall
    • SHARAN, M. & POPEL, A. S. 2001 A two-phase model for flow of blood in narrow tubes with increased effective viscosity near the wall. Biorheology 38, 415-428.
    • (2001) Biorheology , vol.38 , pp. 415-428
    • Sharan, M.1    Popel, A.S.2
  • 24
    • 0038311020 scopus 로고    scopus 로고
    • Near-Wall μPIV reveals a hydrodynamically relevant endothelial surface layer in venules in vivo
    • SMITH, M. L., LONG, D. S., DAMIANO, E. R. & LEY, K. 2003 Near-Wall μPIV reveals a hydrodynamically relevant endothelial surface layer in venules in vivo. Biophys. J. 85, 637-645.
    • (2003) Biophys. J. , vol.85 , pp. 637-645
    • Smith, M.L.1    Long, D.S.2    Damiano, E.R.3    Ley, K.4
  • 25
    • 0023881667 scopus 로고
    • Wall shear rate in arterioles in vivo: Least estimates from platelet velocity profiles
    • TANGELDER, G. J., SLAAF, D. W., ARTS, T & RENEMAN, R. S. 1988 Wall shear rate in arterioles in vivo: least estimates from platelet velocity profiles. Am. J. Physiol. 254, H1059-H1064.
    • (1988) Am. J. Physiol. , vol.254
    • Tangelder, G.J.1    Slaaf, D.W.2    Arts, T.3    Reneman, R.S.4
  • 26
    • 0008964366 scopus 로고
    • The wall effect in capillary instruments: An improved analysis suitable for application to blood and other particulate suspensions
    • THOMAS, H. W. 1962 The wall effect in capillary instruments: an improved analysis suitable for application to blood and other particulate suspensions. Biorheology 1, 41-56.
    • (1962) Biorheology , vol.1 , pp. 41-56
    • Thomas, H.W.1
  • 27
    • 0029797605 scopus 로고    scopus 로고
    • Identification of distinct luminal domains for macromolecules, erythrocytes, and leukocytes within mammalian capillaries
    • VINK, H. & DULING, B. R. 1996 Identification of distinct luminal domains for macromolecules, erythrocytes, and leukocytes within mammalian capillaries. Circ. Res. 79, 581-589.
    • (1996) Circ. Res. , vol.79 , pp. 581-589
    • Vink, H.1    Duling, B.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.