메뉴 건너뛰기




Volumn 31, Issue 6, 2004, Pages 1481-1488

The design and the dosimetry of bi-nuclide radioactive ophthalmic applicators

Author keywords

Beta source; Brachytherapy; Dosimetry; Eye plaque; Iodine 125; Ophthalmic applicator; Plastic scintillator

Indexed keywords

APPLICATORS; RADIOISOTOPES; SCINTILLATION COUNTERS; TUMORS;

EID: 3042640725     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1755471     Document Type: Article
Times cited : (28)

References (31)
  • 2
    • 0033833316 scopus 로고    scopus 로고
    • Tumor location affects the incidence of cataract and retinopathy after ophthalmic plaque radiation therapy
    • P. T. Finger, "Tumor location affects the incidence of cataract and retinopathy after ophthalmic plaque radiation therapy," Br. J. Ophthamol. 84, 1068-1070 (2000).
    • (2000) Br. J. Ophthamol. , vol.84 , pp. 1068-1070
    • Finger, P.T.1
  • 6
    • 0033510719 scopus 로고    scopus 로고
    • Palladium-103 plaque radiotherapy for choroidal melanoma: Results of a 7-year study
    • P. T. Finger, A. Berson, A. Szechter, "Palladium-103 plaque radiotherapy for choroidal melanoma: Results of a 7-year study," Ophthalmology 106, 606-613 (1999).
    • (1999) Ophthalmology , vol.106 , pp. 606-613
    • Finger, P.T.1    Berson, A.2    Szechter, A.3
  • 7
    • 0029867605 scopus 로고    scopus 로고
    • Direct reading measurement of absorbed dose with plastic scintillators - The general concept and applications to ophthalmic plaque dosimetry
    • D. Flühs, M. Heintz, F. Indenkämpen, C. Wieczorek, H. Kolanoski, and U. Quast, "Direct reading measurement of absorbed dose with plastic scintillators-The general concept and applications to ophthalmic plaque dosimetry," Med. Phys. 23, 427-434 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 427-434
    • Flühs, D.1    Heintz, M.2    Indenkämpen, F.3    Wieczorek, C.4    Kolanoski, H.5    Quast, U.6
  • 12
    • 0017346391 scopus 로고
    • Photon mass attenuation and mass energy absorption coefficients for H, C, N, O, Ar, and seven mixtures from 0.1 keV to 20 MeV
    • J. H. Hubbell, "Photon mass attenuation and mass energy absorption coefficients for H, C, N, O, Ar, and seven mixtures from 0.1 keV to 20 MeV," Radiat. Res. 70, 58-81 (1977).
    • (1977) Radiat. Res. , vol.70 , pp. 58-81
    • Hubbell, J.H.1
  • 13
    • 0020213666 scopus 로고
    • Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV
    • J. H. Hubbell, "Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV," Int. J. Appl. Radiat. Isot. 33, 1269-1290 (1982).
    • (1982) Int. J. Appl. Radiat. Isot. , vol.33 , pp. 1269-1290
    • Hubbell, J.H.1
  • 15
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, "Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43," Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 18
    • 33646655506 scopus 로고    scopus 로고
    • Comments on 'Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43'
    • R. W. Kline, "Comments on 'Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43' [Med. Phys. 22, 209-234 (1995)]," Med. Phys. 23, 1579 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1579
    • Kline, R.W.1
  • 19
    • 0028919251 scopus 로고
    • R. W. Kline, "Comments on 'Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43' [Med. Phys. 22, 209-234 (1995)]," Med. Phys. 23, 1579 (1996).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
  • 20
    • 0032444837 scopus 로고    scopus 로고
    • Comments on 'Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43'
    • A. Y. C. Fung, "Comments on 'Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43' [Med. Phys. 22, 209-234 (1995)]," Med. Phys. 25, 2477 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2477
    • Fung, A.Y.C.1
  • 21
    • 0028919251 scopus 로고
    • A. Y. C. Fung, "Comments on 'Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43' [Med. Phys. 22, 209-234 (1995)]," Med. Phys. 25, 2477 (1998).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
  • 22
    • 0032521001 scopus 로고    scopus 로고
    • Clinical impact of implementing AAPM Task Group 43 on permanent prostate brachytherapy using 1-125
    • W. S. Bice, B. R. Prestlidge, J. J. Prete, and D. F. Dubois, "Clinical impact of implementing AAPM Task Group 43 on permanent prostate brachytherapy using 1-125," Int. J. Radiat. Oncol., Biol., Phys. 40, 1237-1241 (1998).
    • (1998) Int. J. Radiat. Oncol., Biol., Phys. , vol.40 , pp. 1237-1241
    • Bice, W.S.1    Prestlidge, B.R.2    Prete, J.J.3    Dubois, D.F.4
  • 23
    • 0032217054 scopus 로고    scopus 로고
    • 103Pd sources
    • 103Pd sources," Med. Phys. 25, 2271-2278 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2271-2278
    • Weaver, K.1
  • 24
    • 0032891406 scopus 로고    scopus 로고
    • Guidance to users of Nycomed Amersham and North American Scientific, Inc., 1-125 Interstitial Sources: Dosimetry and calibration changes: Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry
    • J. F. Williamson, B. M. Coursey, L. A. DeWerd, W. F. Hanson, R. Nath, and G. Ibbott, "Guidance to users of Nycomed Amersham and North American Scientific, Inc., 1-125 Interstitial Sources: Dosimetry and calibration changes: Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry," Med. Phys. 26, 570 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 570
    • Williamson, J.F.1    Coursey, B.M.2    DeWerd, L.A.3    Hanson, W.F.4    Nath, R.5    Ibbott, G.6
  • 25
    • 0033233124 scopus 로고    scopus 로고
    • 1033Pd interstitial brachytherapy sources: Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Subcommittee on Low-Energy Brachytherapy Source Dosimetry
    • 1033Pd interstitial brachytherapy sources: Recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Subcommittee on Low-Energy Brachytherapy Source Dosimetry," Med. Phys. 26, 2529-2530 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 2529-2530
    • Williamson, J.F.1    Coursey, B.M.2    DeWerd, L.A.3    Hanson, W.F.4    Nath, R.5    Rivard, M.J.6    Ibbott, G.7
  • 26
    • 0032936813 scopus 로고    scopus 로고
    • Functional fitting of interstitial brachytherapy dosimetry data recommended by the AAPM Radiation Therapy Committee Task Group 43
    • E. E. Furhang and L. L. Anderson, "Functional fitting of interstitial brachytherapy dosimetry data recommended by the AAPM Radiation Therapy Committee Task Group 43," Med. Phys. 26, 153-160 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 153-160
    • Furhang, E.E.1    Anderson, L.L.2
  • 27
    • 0034002901 scopus 로고    scopus 로고
    • Technical note: Improved analytical fit to the TG-43 radial dose function, g(r)
    • D. C. Moss, "Technical note: Improved analytical fit to the TG-43 radial dose function, g(r)," Med. Phys. 27, 659-661 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 659-661
    • Moss, D.C.1
  • 28
    • 0025743841 scopus 로고
    • Calibration of ophthalmic applicators at NIST: A revised approach
    • C. G. Soares, "Calibration of ophthalmic applicators at NIST: A revised approach," Med. Phys. 18, 787-793 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 787-793
    • Soares, C.G.1
  • 29
    • 0027169865 scopus 로고
    • Measurement of radial dose distributions around small beta particle emitters using high resolution radio-chromic foil dosimetry
    • C. G. Soares and W. L. McLaughlin, "Measurement of radial dose distributions around small beta particle emitters using high resolution radio-chromic foil dosimetry," Radiat. Prot. Dosim. 47, 367-372 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , pp. 367-372
    • Soares, C.G.1    McLaughlin, W.L.2
  • 30
    • 0028047634 scopus 로고
    • 90Y beta-particle ophthalmic applicator dose rates
    • 90Y beta-particle ophthalmic applicator dose rates," Med. Phys. 21, 91-99 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 91-99
    • Deasy, J.O.1    Soares, C.G.2
  • 31
    • 0031942882 scopus 로고    scopus 로고
    • Calibration and characterization of beta-particle sources for intravascular brachytherapy
    • C. G. Soares, D. G. Halpern, and C.-K. Wang, "Calibration and characterization of beta-particle sources for intravascular brachytherapy," Med. Phys. 25, 339-346 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 339-346
    • Soares, C.G.1    Halpern, D.G.2    Wang, C.-K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.