메뉴 건너뛰기




Volumn 66, Issue 3, 1999, Pages 181-186

ABG cementless THR: Description of the implant, medium-term results;Necementovaná náhrada kyčelního kloubu ABG: Popis implantátu, střednědobé výsledky

Author keywords

Cementless THR; Hydroxyapatite; Pressfit principle

Indexed keywords


EID: 3042552630     PISSN: 00015415     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 8844256595 scopus 로고
    • Total Hip Replacement with the ABG Cement-free Hip with Hydroxyapatite
    • Howmedica Publications, January
    • ANDREY, J., BERTEAUX, D., GOALARD, CH. et al.: Total Hip Replacement with the ABG Cement-free Hip with Hydroxyapatite. Early Clinical Results at Three Years. Howmedica Publications, January 1994.
    • (1994) Early Clinical Results at Three Years
    • Andrey, J.1    Berteaux, D.2    Goalard, Ch.3
  • 2
    • 0028006356 scopus 로고
    • An Indirect Comparison of Third-body Year in Retrieved Hydroxyapatitecoated, Porous and Cemented Femoral Components
    • BAUER, T. W., TAXLOR, S. K., JSANG, M., MEDENDORP, S. V.: An Indirect Comparison of Third-body Year in Retrieved Hydroxyapatitecoated, Porous and Cemented Femoral Components. Clin. Orthop., 298: 11-18, 1994.
    • (1994) Clin. Orthop. , vol.298 , pp. 11-18
    • Bauer, T.W.1    Taxlor, S.K.2    Jsang, M.3    Medendorp, S.V.4
  • 3
    • 0026442089 scopus 로고
    • Hydroxyapatite-coated Hip Implants, Multicenter Three-years Clinical and Roentgenographic Results
    • D'ANTONIO, J. A., CAPELLO, W. N., JAFFE, W. L.: Hydroxyapatite-coated Hip Implants, Multicenter Three-years Clinical and Roentgenographic Results. Clin. Orthop., 285: 102-115, 1992.
    • (1992) Clin. Orthop. , vol.285 , pp. 102-115
    • D'Antonio, J.A.1    Capello, W.N.2    Jaffe, W.L.3
  • 4
    • 27844553484 scopus 로고    scopus 로고
    • Zkušenosti s necementovanou endoprotézou kyčelního kloubu Walter-Motorlet
    • HAJNÝ, P., ŠTĚDRY̌, V.: Zkušenosti s necementovanou endoprotézou kyčelního kloubu Walter-Motorlet. Acta Chir. orthop. Traum. čech., 64: 342-346, 1997.
    • (1997) Acta Chir. Orthop. Traum. Čech. , vol.64 , pp. 342-346
    • Hajný, P.1    Štědry̌, V.2
  • 5
    • 0028921627 scopus 로고
    • Short-term Results of Hydroxyapatite-coated Primary Total Hip Arthroplasty
    • ROSSI, P., SIBELLI, P., FUMERO, S., CRUA, E.: Short-term Results of Hydroxyapatite-coated Primary Total Hip Arthroplasty. Clin. Orthop., 310: 98-102, 1995.
    • (1995) Clin. Orthop. , vol.310 , pp. 98-102
    • Rossi, P.1    Sibelli, P.2    Fumero, S.3    Crua, E.4
  • 6
    • 0001893960 scopus 로고
    • Hydroxyapatite Ceramic Coating for Bone Implant Fixation
    • SOBALLE, K.: Hydroxyapatite Ceramic Coating for Bone Implant Fixation. Acta orthop. scand., Suppl. 255: 64, 1993.
    • (1993) Acta Orthop. Scand., Suppl. , vol.255 , pp. 64
    • Soballe, K.1
  • 7
    • 3042525008 scopus 로고
    • Bezcementová endoprotéza kyčelního kloubu ABG: Popis implantátu, operační technika
    • ŠTĚDRÝ, V., MATĚJOVSKÝ, Z.: Bezcementová endoprotéza kyčelního kloubu ABG: popis implantátu, operační technika. Acta Chir. orthop. Traum. čech., 62: 106-110, 1995.
    • (1995) Acta Chir. Orthop. Traum. Čech. , vol.62 , pp. 106-110
    • Štědrý, V.1    Matějovský, Z.2
  • 8
    • 3042631971 scopus 로고
    • Zkušenosti s necementovaným dříkem kyčelní endoprotézy typu Schenker
    • ŠTĚDRÝ, V, VAVROŇ, P.: Zkušenosti s necementovaným dříkem kyčelní endoprotézy typu Schenker. Acta Chir. orthop. Traum. čech., 60: 284-287, 1993.
    • (1993) Acta Chir. Orthop. Traum. Čech. , vol.60 , pp. 284-287
    • Štědrý, V.1    Vavroň, P.2
  • 9
    • 0009747054 scopus 로고
    • Zkušenosti s necementovanou endoprotézou kyčelního kloubu Walter-Motorlet
    • ŠTĚDRÝ, V., VAVROŇ, P.: Zkušenosti s necementovanou endoprotézou kyčelního kloubu Walter-Motorlet. Acta Chir. orthop. Traum. čech., 62: 47-52, 1995.
    • (1995) Acta Chir. Orthop. Traum. Čech. , vol.62 , pp. 47-52
    • Štědrý, V.1    Vavroň, P.2
  • 10
    • 0028230087 scopus 로고
    • The Influence of a Hydroxyapatite Coating and Tricalcium-phosphate Coating on Bone growth into Titanium Fiber-metal Implants
    • TISDEL, C. L., GOLDBERG, V. M., PARR, A. et al.: The Influence of a Hydroxyapatite Coating and Tricalcium-phosphate Coating on Bone growth into Titanium Fiber-metal Implants. J. Bone Jt Surg., 76-A: 159-171, 1994.
    • (1994) J. Bone Jt Surg. , vol.76 A , pp. 159-171
    • Tisdel, C.L.1    Goldberg, V.M.2    Parr, A.3