-
1
-
-
0024017416
-
RF powering of millimeter and submillimeter-sized neural prosthetic implants
-
May
-
William J. Heetderks, "RF Powering of Millimeter and Submillimeter-Sized Neural Prosthetic Implants," IEEE Trans. Biomed. Eng., vol. 35, No. 5, pp. 323-327, May 1988.
-
(1988)
IEEE Trans. Biomed. Eng.
, vol.35
, Issue.5
, pp. 323-327
-
-
Heetderks, W.J.1
-
2
-
-
0015083432
-
An inductively coupled RF system for the transmission of l kW of power through the skin
-
July
-
John C. Schuder, Jerry H. Gold, and Hugh E. Stephenson Jr., "An Inductively Coupled RF System for the Transmission of l kW of Power Through the Skin," IEEE Trans. Biomed. Eng., vol. 18, No. 4, pp. 265-273, July 1971.
-
(1971)
IEEE Trans. Biomed. Eng.
, vol.18
, Issue.4
, pp. 265-273
-
-
Schuder, J.C.1
Gold, J.H.2
Stephenson Jr., H.E.3
-
3
-
-
0017559930
-
Design of radio-frequency powered coils for implant instruments
-
Wen H. Ko, Sheau P. Liang, and Cliff D. F. Fung, "Design of radio-frequency powered coils for implant instruments," Med. & Biol. Eng. & Comput., vol. 15, pp. 634-640, 1977.
-
(1977)
Med. & Biol. Eng. & Comput.
, vol.15
, pp. 634-640
-
-
Ko, W.H.1
Liang, S.P.2
Fung, C.D.F.3
-
4
-
-
0031260315
-
A single-channel implanted microstimulator for functional neuromuscular stimulator
-
October
-
Babak Ziaie, Mark D. Nardin, Anthony R. Coghlan, and Khalil Najafi, "A Single-Channel Implanted Microstimulator for Functional Neuromuscular Stimulator," IEEE Trans. Biomed. Eng., vol. 44, No. 10, pp. 909-920, October 1997.
-
(1997)
IEEE Trans. Biomed. Eng.
, vol.44
, Issue.10
, pp. 909-920
-
-
Ziaie, B.1
Nardin, M.D.2
Coghlan, A.R.3
Najafi, K.4
-
5
-
-
0023378409
-
An external powered, multichannel, implantable stimulator for versatile control of paralyzed muscle
-
July
-
Brian Smith, P. Hunter Peckham, Michael W. Keith, and Dennis D. Roscoe, "An External Powered, Multichannel, Implantable Stimulator for Versatile Control of Paralyzed Muscle," IEEE Trans. Biomed. Eng., vol. 34, No. 7, pp. 499-507, July 1987.
-
(1987)
IEEE Trans. Biomed. Eng.
, vol.34
, Issue.7
, pp. 499-507
-
-
Smith, B.1
Hunter Peckham, P.2
Keith, M.W.3
Roscoe, D.D.4
-
6
-
-
0023324937
-
Radio-frequency coils in implantable devices: Misalignment analysis and design procedure
-
April
-
Mani Soma, Douglas C. Galbraith, and Robert L. White, "Radio-Frequency Coils in Implantable Devices: Misalignment Analysis and Design Procedure," IEEE Trans. Biomed. Eng., vol. 34, No. 4, pp. 276-282, April 1987.
-
(1987)
IEEE Trans. Biomed. Eng.
, vol.34
, Issue.4
, pp. 276-282
-
-
Soma, M.1
Galbraith, D.C.2
White, R.L.3
-
7
-
-
0015029903
-
Mutual inductance of air-cored coils: Effect on design of radiofrequency coupled implants
-
Pergamon Press, January
-
F. C. Flack, E. D. James, and D. M. Schlapp, "Mutual Inductance of Air-cored Coils: Effect on Design of Radiofrequency Coupled Implants," Med. & biol. Eng. Vol. 9, pp. 79-85, Pergamon Press, January1971.
-
(1971)
Med. & Biol. Eng.
, vol.9
, pp. 79-85
-
-
Flack, F.C.1
James, E.D.2
Schlapp, D.M.3
-
8
-
-
0021285916
-
System optimization for improved accuracy in transcutaneous signal and power transmission
-
February
-
Erwin S. Hochmair, "System Optimization for Improved Accuracy in Transcutaneous Signal and Power Transmission," IEEE Trans. Biomed. Eng., vol. 31, No. 2, pp. 177-186, February 1984.
-
(1984)
IEEE Trans. Biomed. Eng.
, vol.31
, Issue.2
, pp. 177-186
-
-
Hochmair, E.S.1
-
9
-
-
0035763550
-
A simple, wireless powering scheme for MEMS devices
-
Jie Wu, Victor Quinn, and Gary H. Bernstein, "A simple, wireless powering scheme for MEMS devices," Proc. of SPIE Vol. 4559, pp. 43-52, 2001.
-
(2001)
Proc. of SPIE
, vol.4559
, pp. 43-52
-
-
Wu, J.1
Quinn, V.2
Bernstein, G.H.3
-
10
-
-
0013788638
-
Energy transport to a coil which circumscribes a ferrite core and is implanted within the body
-
July/October
-
J. C. Schuder, and H. E. Stephenson, Jr., "Energy Transport to a Coil Which Circumscribes a Ferrite Core and Is Implanted Within the Body," IEEE Trans. Biomed. Eng., vol. 12, Nos. 3 and 4, pp. 154-163, July/October 1965.
-
(1965)
IEEE Trans. Biomed. Eng.
, vol.12
, Issue.3-4
, pp. 154-163
-
-
Schuder, J.C.1
Stephenson Jr., H.E.2
-
11
-
-
0029490470
-
Self tuning inductive powering for implantable telemetric monitoring systems
-
Stockholm, Sweden, June 25-29
-
th International Conference on Solid-State Sensors and Actuators, and Eurosensors IX, Stockholm, Sweden, pp. 55-58, June 25-29, 1995.
-
(1995)
th International Conference on Solid-state Sensors and Actuators, and Eurosensors IX
, pp. 55-58
-
-
Van Schuylenbergh, K.1
Puers, R.2
-
12
-
-
3042628783
-
An implantable system for detecting loosening of a hip prosthesis
-
Juneau, USA, Program and abstracts, May 9-14
-
R. Puers, M. Catrysse, G. Vandevoorde, R. J. Collier, E. Louridas, F. Burny, M. Donkerwolcke, and F. Moulart, "An Implantable System for Detecting Loosening of a Hip Prosthesis," in International Symposium on Biotelemetry, Juneau, USA, Program and abstracts, pp. 63-64, May 9-14, 1999.
-
(1999)
International Symposium on Biotelemetry
, pp. 63-64
-
-
Puers, R.1
Catrysse, M.2
Vandevoorde, G.3
Collier, R.J.4
Louridas, E.5
Burny, F.6
Donkerwolcke, M.7
Moulart, F.8
-
13
-
-
0020816152
-
Analysis of resonant coupled coils in the design of radio frequency transcutaneous links
-
September
-
N. de N. Donaldson, and T. A. Perkins, "Analysis of resonant coupled coils in the design of radio frequency transcutaneous links," Med. Biol. Eng. & Comput, Vol. 21, pp. 612-627, September 1983.
-
(1983)
Med. Biol. Eng. & Comput
, vol.21
, pp. 612-627
-
-
Donaldson, N.D.N.1
Perkins, T.A.2
|