메뉴 건너뛰기




Volumn 37, Issue 1, 2006, Pages 41-45

The effect of IV cannula length on the rate of infusion

Author keywords

Flow rate; Hagen Poiseuille's law; Intravenous cannula

Indexed keywords

ARTICLE; CANNULA; CLINICAL PRACTICE; FLOW RATE; FLUID FLOW; INFUSION SYSTEM; INTRAVENOUS CATHETER; MATHEMATICAL COMPUTING; PRIORITY JOURNAL; TURBULENT FLOW;

EID: 30344468790     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2005.09.001     Document Type: Article
Times cited : (24)

References (10)
  • 2
    • 0031244527 scopus 로고    scopus 로고
    • A new method for rapid fluid bolus infusion into a peripheral vein
    • W.E. Franklin, J. Patterson, and M. Kulick A new method for rapid fluid bolus infusion into a peripheral vein Prehosp Emerg Care 1 1997 273 276
    • (1997) Prehosp Emerg Care , vol.1 , pp. 273-276
    • Franklin, W.E.1    Patterson, J.2    Kulick, M.3
  • 3
    • 0028466988 scopus 로고
    • An analysis of the effect of venous resistance on the performance of gravity-fed intravenous infusion systems
    • D.B. Goodie, and J.H. Philip An analysis of the effect of venous resistance on the performance of gravity-fed intravenous infusion systems J Clin Monit 10 1994 222 228
    • (1994) J Clin Monit , vol.10 , pp. 222-228
    • Goodie, D.B.1    Philip, J.H.2
  • 4
    • 0023233076 scopus 로고
    • Flow through intravenous cannulae
    • I.G. Kestin Flow through intravenous cannulae Anaesthesia 42 1987 67 70
    • (1987) Anaesthesia , vol.42 , pp. 67-70
    • Kestin, I.G.1
  • 5
    • 0025891838 scopus 로고
    • Risk factors for infusion-related phlebitis with small peripheral venous catheters. a randomized controlled trial
    • D.G. Maki, and M. Ringer Risk factors for infusion-related phlebitis with small peripheral venous catheters. A randomized controlled trial Ann Intern Med 114 1991 845 854
    • (1991) Ann Intern Med , vol.114 , pp. 845-854
    • Maki, D.G.1    Ringer, M.2
  • 6
    • 0025357076 scopus 로고
    • Disturbances of blood-flow velocity in the dorsal veins of the hand after vein cannulation and cannula fixation in the anaesthetised patient
    • P. Nitescu, N. Larsson, and E. Eriksson Disturbances of blood-flow velocity in the dorsal veins of the hand after vein cannulation and cannula fixation in the anaesthetised patient Acta Anaesthesiol Scand 34 1990 120 125
    • (1990) Acta Anaesthesiol Scand , vol.34 , pp. 120-125
    • Nitescu, P.1    Larsson, N.2    Eriksson, E.3
  • 7
    • 0026719694 scopus 로고
    • An evaluation of the rapid infusion system
    • H.U. Rothen, R. Lauber, and M. Mosimann An evaluation of the rapid infusion system Anaesthesia 47 1992 597 600
    • (1992) Anaesthesia , vol.47 , pp. 597-600
    • Rothen, H.U.1    Lauber, R.2    Mosimann, M.3
  • 8
    • 0017163574 scopus 로고
    • Thrombus formation on indwelling venous cannulae in sheep: Effects of time, size and materials
    • H.G. Spanos, and J.F. Hecker Thrombus formation on indwelling venous cannulae in sheep: effects of time, size and materials Anaesth Intensive Care 4 1976 217 224
    • (1976) Anaesth Intensive Care , vol.4 , pp. 217-224
    • Spanos, H.G.1    Hecker, J.F.2
  • 9
    • 0029052789 scopus 로고
    • An evaluation of methods of increasing the flow rate of i.v. fluid administration
    • M.D. Stoneham An evaluation of methods of increasing the flow rate of i.v. fluid administration Br J Anaesth 75 1995 361 365
    • (1995) Br J Anaesth , vol.75 , pp. 361-365
    • Stoneham, M.D.1
  • 10
    • 0030875933 scopus 로고    scopus 로고
    • Factors affecting flow through blood administration sets
    • M.D. Stoneham Factors affecting flow through blood administration sets Eur J Anaesthesiol 14 1997 333 339
    • (1997) Eur J Anaesthesiol , vol.14 , pp. 333-339
    • Stoneham, M.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.