메뉴 건너뛰기




Volumn 17, Issue 1, 2005, Pages 9-13

A noble RBC aggregometer with vibration-induced disaggregation mechanism

Author keywords

Aggregation; Light; Red blood cell; Reflection; Vibration

Indexed keywords


EID: 30344454439     PISSN: 1226119X     EISSN: 1226119X     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (18)
  • 1
  • 3
    • 0023489487 scopus 로고
    • Aggragtionof red blood cells studied by ultrasound back-scattering phenomenon
    • Boynard, M., J.C. Lelievre and R. Guillet, 1987, Aggragtionof red blood cells studied by ultrasound back-scattering phenomenon, Biorheology 24, 451.
    • (1987) Biorheology , vol.24 , pp. 451
    • Boynard, M.1    Lelievre, J.C.2    Guillet, R.3
  • 4
    • 0015882740 scopus 로고
    • Ultrastructural basis of the mechanism of the rouleaux formation
    • Chien, S. and K. M. Jan, 1973, Ultrastructural basis of the mechanism of the rouleaux formation, Microvas. Res. 5, 155-166.
    • (1973) Microvas. Res. , vol.5 , pp. 155-166
    • Chien, S.1    Jan, K.M.2
  • 5
    • 0020413356 scopus 로고
    • Hemorheologic changes following acute myocardial infarction
    • Dormandy, L., E. Ernst, A. Matrai and P.T. Flute, 1982, Hemorheologic changes following acute myocardial infarction, Am. Heart J. 104, 1364.
    • (1982) Am. Heart J. , vol.104 , pp. 1364
    • Dormandy, L.1    Ernst, E.2    Matrai, A.3    Flute, P.T.4
  • 6
    • 0027983577 scopus 로고
    • Laser-assisted optical rotational cell analyser (L.O.R.C.A); I. A new instrument for measurement of various structural hemorheological parameters
    • Hardeman, M.R., P.T. Goedhart, J.G.G. Dobbe and K.P. Lettinga, 1994, Laser-assisted optical rotational cell analyser (L.O.R.C.A); I. A new instrument for measurement of various structural hemorheological parameters, Clinical Hemorheology 14, 605-618.
    • (1994) Clinical Hemorheology , vol.14 , pp. 605-618
    • Hardeman, M.R.1    Goedhart, P.T.2    Dobbe, J.G.G.3    Lettinga, K.P.4
  • 9
    • 0036840107 scopus 로고    scopus 로고
    • Depletion-mediated red blood cell aggregation in polymer solutions
    • Neu, B. and H. J. Meiselman, 2002, Depletion-mediated red blood cell aggregation in polymer solutions, Biophys. J. 83, 2482.
    • (2002) Biophys. J. , vol.83 , pp. 2482
    • Neu, B.1    Meiselman, H.J.2
  • 10
    • 0033498744 scopus 로고    scopus 로고
    • Dielectric approach to the investigation of erythrocyte aggregation: I. Experimental basis of the method
    • Pribush, A., H.J. Meiselman, D. Meyerstein and N. Meyerstein, 1999, Dielectric approach to the investigation of erythrocyte aggregation: I. Experimental basis of the method, Biorheology 36, 411.
    • (1999) Biorheology , vol.36 , pp. 411
    • Pribush, A.1    Meiselman, H.J.2    Meyerstein, D.3    Meyerstein, N.4
  • 11
    • 0001917006 scopus 로고
    • Red cell aggregation and yield stress
    • edited by G.D. Lowe, CRC Press, Boca Raton, Florida, USA
    • Rampling, M.W., 1988, Red cell aggregation and yield stress, in Clinical Blood Rheology Vol. 1, edited by G.D. Lowe, CRC Press, Boca Raton, Florida, USA.
    • (1988) Clinical Blood Rheology , vol.1
    • Rampling, M.W.1
  • 12
    • 1942485828 scopus 로고    scopus 로고
    • Influence of cell-specific factors on red blood cell aggregation
    • Rampling, M. W., H. J. Meiselman, B. Neu and O. K. Baskurt, 2004, Influence of cell-specific factors on red blood cell aggregation, Biorheology 41, 91.
    • (2004) Biorheology , vol.41 , pp. 91
    • Rampling, M.W.1    Meiselman, H.J.2    Neu, B.3    Baskurt, O.K.4
  • 13
    • 0034860375 scopus 로고    scopus 로고
    • Light scattering changes caused by RBC aggregation: Physical basis for new approach to non-invasive blood count
    • Shvartsman, L.D. and I. Fine, 2001, Light scattering changes caused by RBC aggregation: physical basis for new approach to non-invasive blood count, SPIE proc. 4263, 122.
    • (2001) SPIE Proc. , vol.4263 , pp. 122
    • Shvartsman, L.D.1    Fine, I.2
  • 14
    • 0242289521 scopus 로고    scopus 로고
    • Characteristics of blood flow resistance under transverse vibration: Red blood cell suspension in Dextran-40
    • Shin, S., Y.H. Ku, J.S. Suh, S.Y. Moon and J.Y. Jang, 2003, Characteristics of blood flow resistance under transverse vibration: red blood cell suspension in Dextran-40, Annals of Biomedical Engineering 31, 1077.
    • (2003) Annals of Biomedical Engineering , vol.31 , pp. 1077
    • Shin, S.1    Ku, Y.H.2    Suh, J.S.3    Moon, S.Y.4    Jang, J.Y.5
  • 15
    • 30344440871 scopus 로고    scopus 로고
    • Measurement of red blood cell aggregation by analysis of light transmission in a pressure-driven slit flow system
    • Shin, S., M.S. Park, J.H. Jang, Y.H. Ku and J.S. Suh, 2004, Measurement of red blood cell aggregation by analysis of light transmission in a pressure-driven slit flow system, Korea-Austrailia Rheology Journal 16, 129
    • (2004) Korea-Austrailia Rheology Journal , vol.16 , pp. 129
    • Shin, S.1    Park, M.S.2    Jang, J.H.3    Ku, Y.H.4    Suh, J.S.5
  • 16
    • 30344441992 scopus 로고    scopus 로고
    • Light-transmission aggregometer using a vibration-induced disaggregation mechanism
    • Shin, S., J.H. Jang, M.S. Park, Y.H. Ku and J.S. Suh, 2005, Light-transmission aggregometer using a vibration-induced disaggregation mechanism, Review of Scientific Instrum. 76, 016107 1.
    • (2005) Review of Scientific Instrum. , vol.76 , pp. 0161071
    • Shin, S.1    Jang, J.H.2    Park, M.S.3    Ku, Y.H.4    Suh, J.S.5
  • 18
    • 0033494388 scopus 로고    scopus 로고
    • Comparison of three optical methods to study erythrocyte aggregation
    • Zhao, H., X. Wang and J.F. Stolz, 1999, Comparison of three optical methods to study erythrocyte aggregation, Clinical Hemorheol. And Microcirc. 21, 297.
    • (1999) Clinical Hemorheol. and Microcirc. , vol.21 , pp. 297
    • Zhao, H.1    Wang, X.2    Stolz, J.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.