Volumn 55, Issue 1, 2006, Pages 147-152

Rapid mapping of flow velocity usine a new PARSE method

Author keywords

Flow quantification; Inverse problems; Parametric imaging; Single shot MRI; Velocity images

Indexed keywords

FLOW VELOCITY; MAGNETIC RESONANCE IMAGING; MAPPING; SIGNAL ENCODING; VELOCITY;

EID: 30344453653     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20750     Document Type: Article
Times cited : (6)

References (19)
  • 1
    • 0020523896 scopus 로고
    • Nuclear magnetic resonance blood flow measurements in the human brain
    • Singer JR, Crooks LE. Nuclear magnetic resonance blood flow measurements in the human brain. Science 1983;221:654-656.
    • (1983) Science , vol.221 , pp. 654-656
    • Singer, J.R.1    Crooks, L.E.2
  • 2
    • 0020340302 scopus 로고
    • A flow zeugmatographic interlace for NMR imaging in humans
    • Moran PR. A flow zeugmatographic interlace for NMR imaging in humans. Magn Reson Med 1982;1:197-203.
    • (1982) Magn Reson Med , vol.1 , pp. 197-203
    • Moran, P.R.1
  • 3
    • 0023007579 scopus 로고
    • Magnetic resonance angiography
    • Dumoulin CL, Hart HR. Magnetic resonance angiography. Radiology 1986;161:717-720.
    • (1986) Radiology , vol.161 , pp. 717-720
    • Dumoulin, C.L.1    Hart, H.R.2
  • 7
    • 0026185137 scopus 로고
    • Phase-contrast MR angiography with reduced acquisition time: New concepts in sequence design
    • Hausmann R, Lewin JS, Laub G. Phase-contrast MR angiography with reduced acquisition time: new concepts in sequence design. J Magn Reson Imaging 1991;1:415-422.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 415-422
    • Hausmann, R.1    Lewin, J.S.2    Laub, G.3
  • 8
    • 0028095056 scopus 로고
    • Magnetic resonance velocity imaging using a fast spiral phase contrast sequence
    • Pike GB, Meyer CH, Brosnan TJ, Pelc NJ. Magnetic resonance velocity imaging using a fast spiral phase contrast sequence. Magn Reson Med 1994;32:476-483.
    • (1994) Magn Reson Med , vol.32 , pp. 476-483
    • Pike, G.B.1    Meyer, C.H.2    Brosnan, T.J.3    Pelc, N.J.4
  • 10
    • 0042592959 scopus 로고    scopus 로고
    • Rapid quantification of high-speed flow jets
    • Nayak, KS, Hu BS, Nishimura DG. Rapid quantification of high-speed flow jets. Magn Reson Med 2003;50:366-372.
    • (2003) Magn Reson Med , vol.50 , pp. 366-372
    • Nayak, K.S.1    Hu, B.S.2    Nishimura, D.G.3
  • 11
    • 0344305574 scopus 로고    scopus 로고
    • Real-time volumetric flow measurements with complex-difference MRI
    • Thompson RB, McVeigh ER. Real-time volumetric flow measurements with complex-difference MRI. Magn Reson Med 2003;50:1248-1255.
    • (2003) Magn Reson Med , vol.50 , pp. 1248-1255
    • Thompson, R.B.1    McVeigh, E.R.2
  • 12
    • 0028509583 scopus 로고
    • Effects of intravoxel velocity distributions on the accuracy of the phase-mapping method in phase-contrast MR angiograpy
    • Hamilton CA, Moran PR, Santago II P, Rajala SA. Effects of intravoxel velocity distributions on the accuracy of the phase-mapping method in phase-contrast MR angiograpy. J Magn Reson Imaging 1994;4;752-755.
    • (1994) J Magn Reson Imaging , vol.4 , pp. 752-755
    • Hamilton, C.A.1    Moran, P.R.2    Santago, I.I.P.3    Rajala, S.A.4
  • 13
    • 0032833835 scopus 로고    scopus 로고
    • Flow quantification using low-spatial-resolution and low-velocity- resolution velocity images
    • Tsai CM, Olcott EW, Nishimura DG. Flow quantification using low-spatial-resolution and low-velocity-resolution velocity images. Magn Reson Med 1999;42:682-690.
    • (1999) Magn Reson Med , vol.42 , pp. 682-690
    • Tsai, C.M.1    Olcott, E.W.2    Nishimura, D.G.3
  • 15
    • 0242290944 scopus 로고    scopus 로고
    • Parsing local signal evolution directly from a single-shot MRI signal: A new approach for fMRI
    • Twieg DB. Parsing local signal evolution directly from a single-shot MRI signal: a new approach for fMRI. Magn Reson Med 2003;50:1043-1052.
    • (2003) Magn Reson Med , vol.50 , pp. 1043-1052
    • Twieg, D.B.1
  • 16
    • 0031195397 scopus 로고    scopus 로고
    • Multishot rosette trajectories for spectrally selective MR imaging
    • Noll DC. Multishot rosette trajectories for spectrally selective MR imaging. IEEE Trans Med Imaging 1997;16:372-377.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 372-377
    • Noll, D.C.1
  • 18
    • 0030797553 scopus 로고    scopus 로고
    • Density compensation functions for spiral MRI
    • Hoge RD, Kwan RKS, Pike GB. Density compensation functions for spiral MRI. Magn Reson Med 1997;38:117-128.
    • (1997) Magn Reson Med , vol.38 , pp. 117-128
    • Hoge, R.D.1    Kwan, R.K.S.2    Pike, G.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.