메뉴 건너뛰기




Volumn 1, Issue , 2005, Pages 695-699

Comparison of temperature measurements in fire test furnaces using aspirated thermocouples

Author keywords

[No Author keywords available]

Indexed keywords

ASPIRATED THERMOCOUPLES; FIRE TEST FURNACES; GAS TEMPERATURE MEASUREMENT;

EID: 29744462056     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1115/HT2005-72548     Document Type: Conference Paper
Times cited : (2)

References (14)
  • 5
    • 3342878784 scopus 로고
    • The plate thermometer - A simple instrument for reaching harmonized fire resistance tests
    • Nordtest Project 609-86, Borås, Sweden
    • Wickström, U., 1989, "The Plate Thermometer - A Simple Instrument for Reaching Harmonized Fire Resistance Tests," Nordtest Project 609-86, SP Report 1989:03, Borås, Sweden.
    • (1989) SP Report , vol.1989 , Issue.3
    • Wickström, U.1
  • 6
    • 24844439220 scopus 로고
    • The theory and application of the suction pyrometer
    • Schack, A., 1939, "The Theory and Application of the Suction Pyrometer," J. Inst. Fuel, 12, pp S30-38.
    • (1939) J. Inst. Fuel , vol.12
    • Schack, A.1
  • 7
    • 0018534718 scopus 로고
    • A simple aspirated thermocouple for use in fire
    • Newman, J.S., and Croce, P.A., 1979, "A Simple Aspirated Thermocouple for Use in Fire," J. Fire and Flammability, 10, pp. 327-336.
    • (1979) J. Fire and Flammability , vol.10 , pp. 327-336
    • Newman, J.S.1    Croce, P.A.2
  • 9
    • 0028698355 scopus 로고
    • Transport and oxidation of compartment fire exhaust gases in an adjacent corridor
    • Lattimer, B.Y., Ewens, D.S., Vandsburger, U., and Roby, R.J., 1994, "Transport and Oxidation of Compartment Fire Exhaust Gases in an Adjacent Corridor," J. of Fire Prot. Engr., 6, pp. 163-181.
    • (1994) J. of Fire Prot. Engr. , vol.6 , pp. 163-181
    • Lattimer, B.Y.1    Ewens, D.S.2    Vandsburger, U.3    Roby, R.J.4
  • 10
    • 0042189838 scopus 로고
    • Compartment fire near-field entrainment measurements
    • Dembsey, N.A., Pagni, P.J., and Wiliamson, R.B., 1995, Compartment Fire Near-Field Entrainment Measurements," Fire Saf. J., 24, pp. 383-419.
    • (1995) Fire Saf. J. , vol.24 , pp. 383-419
    • Dembsey, N.A.1    Pagni, P.J.2    Wiliamson, R.B.3
  • 12
    • 4243199113 scopus 로고
    • Suction pyrometry
    • Land, T., Barber, R., 1956, "Suction Pyrometry," Instrum. Autom., 29, pp1314-1320.
    • (1956) Instrum. Autom. , vol.29 , pp. 1314-1320
    • Land, T.1    Barber, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.