메뉴 건너뛰기




Volumn 62, Issue 2, 2004, Pages 214-217

Double-wire technique for access into a protruding aorto-ostial stent for treatment of in-stent restenosis

Author keywords

Aorto ostial stenosis; Restenosis; Stents

Indexed keywords

AGED; ANGIOCARDIOGRAPHY; ANGIOPLASTY; AORTA; AORTOOSTIAL STENT; ARTICLE; CASE REPORT; CORONARY STENT; DOUBLE WIRE TECHNIQUE; ELASTICITY; FEMALE; GUIDE WIRE; HEART INFARCTION; HUMAN; IN STENT RESTENOSIS; OSTIAL STENT; RESTENOSIS; RIGHT CORONARY ARTERY; SURGICAL TECHNIQUE; VASCULAR ACCESS;

EID: 2942744562     PISSN: 15221946     EISSN: None     Source Type: Journal    
DOI: 10.1002/ccd.20062     Document Type: Article
Times cited : (32)

References (26)
  • 4
    • 0025851713 scopus 로고
    • Regional differences in elastic recoil after percutaneous transluminal coronaryangioplasty: A quantitative angiographic study
    • Rensing BJ, Hermann WR, Strauss BH, Serruys PW. Regional differences in elastic recoil after percutaneous transluminal coronaryangioplasty: a quantitative angiographic study. J Am Coll Cardiol 1991;17:34B-38B.
    • (1991) J Am Coll Cardiol , vol.17
    • Rensing, B.J.1    Hermann, W.R.2    Strauss, B.H.3    Serruys, P.W.4
  • 5
    • 0027446466 scopus 로고
    • Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents
    • Haude M, Erbel R, Issa H, Meyer J. Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents. J Am Coll Cardiol 1992;21:26-34, 1993.
    • (1992) J Am Coll Cardiol , vol.21 , pp. 26-34
    • Haude, M.1    Erbel, R.2    Issa, H.3    Meyer, J.4
  • 6
    • 0031854428 scopus 로고    scopus 로고
    • Superimposed stents in the management of acute recoil after Palmaz-Schatz stenting
    • Lederman RJ, Moscucci M. Superimposed stents in the management of acute recoil after Palmaz-Schatz stenting. Cathet Cardiovasc Diagn 1998;44:407-410.
    • (1998) Cathet Cardiovasc Diagn , vol.44 , pp. 407-410
    • Lederman, R.J.1    Moscucci, M.2
  • 7
    • 0026083359 scopus 로고
    • Atherectomy of right coronary artery ostial stenoses: Initial and long-term results, technical features, and histologic findings
    • Popma J, Dick R, Haudenschild C, Topol E. Atherectomy of right coronary artery ostial stenoses: initial and long-term results, technical features, and histologic findings. Am J Cardiol 1991;67:431-433.
    • (1991) Am J Cardiol , vol.67 , pp. 431-433
    • Popma, J.1    Dick, R.2    Haudenschild, C.3    Topol, E.4
  • 12
    • 0029892364 scopus 로고    scopus 로고
    • Do excimer laser angioplasty and rotational atherectomy facilitate balloon angioplasty? Implications for lesion-specific coronary intervention
    • Safian RD, Freed M, Reddy V, Kuntz RE, Baim DS, Grines CL, O'Neill WW. Do excimer laser angioplasty and rotational atherectomy facilitate balloon angioplasty? implications for lesion-specific coronary intervention. J Am Coll Cardiol 1996;27:552-559.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 552-559
    • Safian, R.D.1    Freed, M.2    Reddy, V.3    Kuntz, R.E.4    Baim, D.S.5    Grines, C.L.6    O'Neill, W.W.7
  • 14
    • 0008841262 scopus 로고
    • Coronary stenting for ostial stenosis: Initial results and six month follow-up
    • Terstein P, Stratienko AA, Schatz RA. Coronary stenting for ostial stenosis: initial results and six month follow-up. Circulation 1991; 84(Suppl 2):II-250.
    • (1991) Circulation , vol.84 , Issue.SUPPL. 2
    • Terstein, P.1    Stratienko, A.A.2    Schatz, R.A.3
  • 16
    • 0028820971 scopus 로고
    • Coronary stenting for treatment of ostial stenoses of native coronary arteries or aorto-cororonary venous grafts
    • Rocha-Singh K, Morris N, Wong SC, Schatz RA, Teirstein PS. Coronary stenting for treatment of ostial stenoses of native coronary arteries or aorto-cororonary venous grafts. Am J Cardiol 1995;75:26-29.
    • (1995) Am J Cardiol , vol.75 , pp. 26-29
    • Rocha-Singh, K.1    Morris, N.2    Wong, S.C.3    Schatz, R.A.4    Teirstein, P.S.5
  • 19
    • 0027446466 scopus 로고
    • Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents
    • Haude M, Erbel R, Issa H, Meyer J. Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents. J Am Coll Cardiol 1993;21:26-37.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 26-37
    • Haude, M.1    Erbel, R.2    Issa, H.3    Meyer, J.4
  • 23
  • 26
    • 0034946961 scopus 로고    scopus 로고
    • Inadvertent stent extraction six months after implantation by an entrapped cutting balloon
    • Harb TS, Ling FS. Inadvertent stent extraction six months after implantation by an entrapped cutting balloon. Catheter Cardiovasc Interv 2001;53:415-419.
    • (2001) Catheter Cardiovasc Interv , vol.53 , pp. 415-419
    • Harb, T.S.1    Ling, F.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.