메뉴 건너뛰기




Volumn 51, Issue 7, 2004, Pages 1242-1250

A novel electrode array for diameter-dependent control of axonal excitability: A simulation study

Author keywords

Neural prostheses; Recruitment order; Selective neural stimulation

Indexed keywords

COMPUTER SIMULATION; CORROSION; ELECTRODES; FINITE ELEMENT METHOD; MATHEMATICAL MODELS; MUSCLE; NEUROLOGY; PHYSIOLOGY;

EID: 2942744519     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/TBME.2004.827347     Document Type: Article
Times cited : (25)

References (28)
  • 1
    • 0016615564 scopus 로고
    • A percutaneous wire electrode for chronic research use
    • May
    • C. W. Caldwell and J. B. Reswick, "A percutaneous wire electrode for chronic research use," IEEE Trans. Biomed. Eng., vol. BME-22, pp. 429-432, May 1975.
    • (1975) IEEE Trans. Biomed. Eng. , vol.BME-22 , pp. 429-432
    • Caldwell, C.W.1    Reswick, J.B.2
  • 2
    • 0022590426 scopus 로고
    • Recruitment properties of monopolar and bipolar epimysial electrodes
    • P. A. Grandjean and J. T. Mortimer, "Recruitment properties of monopolar and bipolar epimysial electrodes," Ann. Biomed. Eng, vol. 14, no, 1, pp. 53-66, 1986.
    • (1986) Ann. Biomed. Eng , vol.14 , Issue.1 , pp. 53-66
    • Grandjean, P.A.1    Mortimer, J.T.2
  • 3
    • 0021804032 scopus 로고
    • Acute and chronic implantation of coiled wire intraneural electrodes during cyclical electrical stimulation
    • B. R. Bowman and R. C. Erickson, "Acute and chronic implantation of coiled wire intraneural electrodes during cyclical electrical stimulation," Ann. Biomed. Eng., vol. 13, no. 1, pp, 75-93, 1985.
    • (1985) Ann. Biomed. Eng. , vol.13 , Issue.1 , pp. 75-93
    • Bowman, B.R.1    Erickson, R.C.2
  • 4
    • 0024116463 scopus 로고
    • A spiral nerve cuff electrode for peripheral nerve stimulation
    • Nov.
    • G. G. Naples et al., "A spiral nerve cuff electrode for peripheral nerve stimulation," IEEE Trans. Biomed. Eng., vol. 35, pp. 905-916, Nov. 1988.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , pp. 905-916
    • Naples, G.G.1
  • 5
    • 0003601806 scopus 로고
    • Springfield, IL: Charles C. Thomas
    • I. Tasaki, Nervous Transmission. Springfield, IL: Charles C. Thomas, 1953.
    • (1953) Nervous Transmission
    • Tasaki, I.1
  • 6
    • 0021645235 scopus 로고
    • External control of the neuromuscular system
    • Dec.
    • M. Solomonow, "External control of the neuromuscular system," IEEE Trans. Biomed. Eng., vol. BME-31, pp. 752-763, Dec. 1984.
    • (1984) IEEE Trans. Biomed. Eng. , vol.BME-31 , pp. 752-763
    • Solomonow, M.1
  • 7
    • 0026107592 scopus 로고
    • A method to effect physiological recruitment order in electrically activated muscle
    • Feb.
    • Z. P. Fang and J. T. Mortimer, "A method to effect physiological recruitment order in electrically activated muscle," IEEE Trans. Biomed. Eng., vol. 38, pp. 175-179, Feb. 1991.
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , pp. 175-179
    • Fang, Z.P.1    Mortimer, J.T.2
  • 8
    • 0027510672 scopus 로고
    • Multielectrode spiral cuff for ordered and reversed activation of nerve fibers
    • J. Rozman et al., "Multielectrode spiral cuff for ordered and reversed activation of nerve fibers," J. Biomed. Eng., vol. 15, no. 2, pp. 113-120, 1993.
    • (1993) J. Biomed. Eng. , vol.15 , Issue.2 , pp. 113-120
    • Rozman, J.1
  • 9
    • 0028227381 scopus 로고
    • Selective sacral root stimulation for bladder control: Acute experiments in an animal model
    • E. L. Koldewijn et al., "Selective sacral root stimulation for bladder control: acute experiments in an animal model," J. Urol., vol. 151, no. 6, pp. 1674-1679, 1994.
    • (1994) J. Urol. , vol.151 , Issue.6 , pp. 1674-1679
    • Koldewijn, E.L.1
  • 10
    • 0030975592 scopus 로고    scopus 로고
    • Selective detrusor activation by electrical stimulation of the human sacral nerve roots
    • N. S. Rijkhoff et al., "Selective detrusor activation by electrical stimulation of the human sacral nerve roots," Artif. Organs, vol. 21, no. 3, pp. 223-226, 1997.
    • (1997) Artif. Organs , vol.21 , Issue.3 , pp. 223-226
    • Rijkhoff, N.S.1
  • 11
    • 0036138562 scopus 로고    scopus 로고
    • Selective suppression of sphincter activation during sacral anterior nerve root stimulation
    • N. Bhadra et al., "Selective suppression of sphincter activation during sacral anterior nerve root stimulation," Neurourol. Urodyn., vol. 21, no. 1, pp. 55-64, 2002.
    • (2002) Neurourol. Urodyn. , vol.21 , Issue.1 , pp. 55-64
    • Bhadra, N.1
  • 12
    • 0028362950 scopus 로고
    • Selective stimulation of smaller fibers in a compound nerve trunk with single cathode by rectangular current pulses
    • Mar.
    • C. Tai and D. Jiang, "Selective stimulation of smaller fibers in a compound nerve trunk with single cathode by rectangular current pulses," IEEE Trans. Biomed. Eng., vol. 41, pp. 286-291, Mar. 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , pp. 286-291
    • Tai, C.1    Jiang, D.2
  • 13
    • 0029329256 scopus 로고
    • Stimulus waveforms for selective neural stimulation
    • Apr.
    • W. M. Grill and J. T. Mortimer, "Stimulus waveforms for selective neural stimulation," IEEE Eng. Med. Biol. Mag., vol. 14, pp. 375-385, Apr. 1995.
    • (1995) IEEE Eng. Med. Biol. Mag. , vol.14 , pp. 375-385
    • Grill, W.M.1    Mortimer, J.T.2
  • 14
    • 0035972867 scopus 로고    scopus 로고
    • A nerve stimulation method to selectively recruit smaller motor-units in rat skeletal muscle
    • A. I. Van Bolhuis, J. Holsheimer, and H. H. Savelberg, "A nerve stimulation method to selectively recruit smaller motor-units in rat skeletal muscle," J. Neurosci. Meth., vol. 107, no. 1-2, pp. 87-92, 2001.
    • (2001) J. Neurosci. Meth. , vol.107 , Issue.1-2 , pp. 87-92
    • Van Bolhuis, A.I.1    Holsheimer, J.2    Savelberg, H.H.3
  • 15
    • 0035489503 scopus 로고    scopus 로고
    • The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic volume conductor model
    • K. E. Deurloo, J. Holsheimer, and P. Bergveld, "The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic volume conductor model," Biol. Cybern., vol. 85, no. 4, pp. 281-291, 2001.
    • (2001) Biol. Cybern. , vol.85 , Issue.4 , pp. 281-291
    • Deurloo, K.E.1    Holsheimer, J.2    Bergveld, P.3
  • 16
    • 0002027562 scopus 로고
    • Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation
    • W. F. M. Agnew, Ed. Englewood Cliffs, NJ: Prentice-Hall
    • L. S. Robblee and T. L. Rose, "Electrochemical guidelines for selection of protocols and electrode materials for neural stimulation," in Neural Prostheses: Fundamental Studies, W. F. M. Agnew, Ed. Englewood Cliffs, NJ: Prentice-Hall, 1990, pp. 25-66.
    • (1990) Neural Prostheses: Fundamental Studies , pp. 25-66
    • Robblee, L.S.1    Rose, T.L.2
  • 17
    • 0017103492 scopus 로고
    • Analysis of a model for excitation of myelinated nerve
    • Apr.
    • D. R. McNeal, "Analysis of a model for excitation of myelinated nerve," IEEE Trans. Biomed. Eng., vol. BME-23, pp. 329-337, Apr. 1976.
    • (1976) IEEE Trans. Biomed. Eng. , vol.BME-23 , pp. 329-337
    • McNeal, D.R.1
  • 18
    • 0029055254 scopus 로고
    • Action potentials and membrane currents in the human node of Ranvier
    • J. R. Schwarz, G. Reid, and H. Bostock, "Action potentials and membrane currents in the human node of Ranvier," Pflugers Arch., vol. 430, no. 2, pp. 283-292, 1995.
    • (1995) Pflugers Arch. , vol.430 , Issue.2 , pp. 283-292
    • Schwarz, J.R.1    Reid, G.2    Bostock, H.3
  • 19
    • 0034233928 scopus 로고    scopus 로고
    • Modeling the effects of electric fields on nerve fibers: Influence of the myelin sheath
    • A. G. Richardson, C. C. McIntyre, and W. M. Grill, "Modeling the effects of electric fields on nerve fibers: influence of the myelin sheath," Med. Biol. Eng. Comput., vol. 38, no. 4, pp. 438-446, 2000.
    • (2000) Med. Biol. Eng. Comput. , vol.38 , Issue.4 , pp. 438-446
    • Richardson, A.G.1    McIntyre, C.C.2    Grill, W.M.3
  • 20
    • 0001489697 scopus 로고
    • Conduction velocity and diameter of nerve
    • J. M. Hursh, "Conduction velocity and diameter of nerve," Amer. J. Physiol., vol. 127, p. 131, 1939.
    • (1939) Amer. J. Physiol. , vol.127 , pp. 131
    • Hursh, J.M.1
  • 22
    • 0029964010 scopus 로고    scopus 로고
    • Morphometric data of canine sacral nerve roots with reference to electrical sacral root stimulation
    • N. J. Rijkhoff et al., "Morphometric data of canine sacral nerve roots with reference to electrical sacral root stimulation," Neurourol. Urodyn., vol. 15, no. 3, pp. 235-248, 1996.
    • (1996) Neurourol. Urodyn. , vol.15 , Issue.3 , pp. 235-248
    • Rijkhoff, N.J.1
  • 23
    • 0031106339 scopus 로고    scopus 로고
    • Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
    • Jan.
    • P. Koole et al., "Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode," IEEE Trans. Rehab. Eng., vol. 5, pp. 40-50, Jan. 1997.
    • (1997) IEEE Trans. Rehab. Eng. , vol.5 , pp. 40-50
    • Koole, P.1
  • 24
    • 0012183991 scopus 로고
    • Specific impedance of the dorsal columns of cat; an anisotropic medium
    • J. B. Ranck and S. L. Be Ment, "Specific impedance of the dorsal columns of cat; an anisotropic medium," Exp. Neurol., vol. 11, pp. 451-463, 1965.
    • (1965) Exp. Neurol. , vol.11 , pp. 451-463
    • Ranck, J.B.1    Be Ment, S.L.2
  • 25
    • 0014088178 scopus 로고
    • The specific resistance of biological material - A compendium of data for the biomedical engineer and physiologist
    • L. A. Geddes and L. E. Baker, "The specific resistance of biological material-a compendium of data for the biomedical engineer and physiologist," Med. Biol. Eng., vol. 5, no. 3, pp. 271-293, 1967.
    • (1967) Med. Biol. Eng. , vol.5 , Issue.3 , pp. 271-293
    • Geddes, L.A.1    Baker, L.E.2
  • 26
    • 0024693339 scopus 로고
    • Analysis of models for extracellular fiber stimulation
    • F. Rattay, "Analysis of models for extracellular fiber stimulation," IEEE Trans. Biomed. Eng., vol. 36, pp. 676-682, July 1989.
    • (1989) IEEE Trans. Biomed. Eng. , vol.36 , pp. 676-682
    • Rattay, F.1
  • 27
    • 0026544327 scopus 로고
    • Damage in peripheral nerve from continuous electrical stimulation: Comparison of two stimulus waveforms
    • D. B. McCreery et al., "Damage in peripheral nerve from continuous electrical stimulation: comparison of two stimulus waveforms," Med. Biol. Eng. Comput., vol. 30, no. 1, pp, 109-114, 1992.
    • (1992) Med. Biol. Eng. Comput. , vol.30 , Issue.1 , pp. 109-114
    • McCreery, D.B.1
  • 28
    • 0031293951 scopus 로고    scopus 로고
    • Alteration of neural geometry for selective nerve stimulation
    • D. J. Tyler and D. M. Durand, "Alteration of neural geometry for selective nerve stimulation," in Proc. 19th Int. Conf IEEE/EMBS, 1997, pp. 2002-2003.
    • (1997) Proc. 19th Int. Conf IEEE/EMBS , pp. 2002-2003
    • Tyler, D.J.1    Durand, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.