메뉴 건너뛰기




Volumn 24, Issue 4, 2004, Pages 139-144

Identification of transients on transmission lines caused by direct lightning strokes based on multiresolution signal decomposition

Author keywords

Direct lightning stroke; High frequency interference; Transient characteristics; Transmission lines

Indexed keywords

ELECTRIC POWER SYSTEM PROTECTION; WAVELET TRANSFORMS;

EID: 2942724535     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (78)

References (11)
  • 1
    • 85095912894 scopus 로고
    • High speed relaying using travelling wave transient analysis
    • New York
    • Dommel H W, Michels J M. High speed relaying using travelling wave transient analysis [C]. IEEE PES Winter Meeting. New York: 1978.
    • (1978) IEEE PES Winter Meeting
    • Dommel, H.W.1    Michels, J.M.2
  • 2
    • 0018038509 scopus 로고
    • Ultra high speed relay for EHV/UHV transmission lines-development, design and application
    • Chamia M, Liberman S. Ultra high speed relay for EHV/UHV transmission lines-development, design and application [J]. IEEE Trans on PAS, 1978, 97(6): 2104-2116.
    • (1978) IEEE Trans. on PAS , vol.97 , Issue.6 , pp. 2104-2116
    • Chamia, M.1    Liberman, S.2
  • 3
    • 0028384045 scopus 로고
    • Non-unit protection technique for EHV transmission systems based on fault-generated noise. Part1: Signal measurement
    • Johns A T, Aggarwal R K, Bo Z Q. Non-unit protection technique for EHV transmission systems based on fault-generated noise, Part1: signal measurement [J]. IEE Proceedings Generation, Transmission and Distribution, 1994, 141(2): 133-140.
    • (1994) IEE Proceedings Generation, Transmission and Distribution , vol.141 , Issue.2 , pp. 133-140
    • Johns, A.T.1    Aggarwal, R.K.2    Bo, Z.Q.3
  • 4
    • 0028385777 scopus 로고
    • Non-unit protection technique for EHV transmission systems based on fault-generated noise. Part2: Signal processing
    • Johns A T, Aggarwal R K, Bo Z Q. Non-unit protection technique for EHV transmission systems based on fault-generated noise, Part2: signal Processing [J]. IEE Proceedings Generation, Transmission and Distribution, 1994, 141(2): 141-147.
    • (1994) IEE Proceedings Generation, Transmission and Distribution , vol.141 , Issue.2 , pp. 141-147
    • Johns, A.T.1    Aggarwal, R.K.2    Bo, Z.Q.3
  • 5
    • 0035376940 scopus 로고    scopus 로고
    • A wavelet analysis based non-communication protection scheme for transmission lines
    • Lin Xiangning, Liu Pei, Yang Chunming, et al. A wavelet analysis based non-communication protection scheme for transmission lines [J]. Proceedings of the CSEE, 2001, 21(6): 9-14.
    • (2001) Proceedings of the CSEE , vol.21 , Issue.6 , pp. 9-14
    • Lin, X.1    Liu, P.2    Yang, C.3
  • 6
    • 2942743892 scopus 로고    scopus 로고
    • Chinese source
  • 7
    • 0030285961 scopus 로고    scopus 로고
    • Discrete wavelet analysis of power system transients
    • Wilkinson W A, Cox M D. Discrete wavelet analysis of power system transients [J]. IEEE Trans. on Power Delivery, 1996, 11(4): 2038-2044.
    • (1996) IEEE Trans. on Power Delivery , vol.11 , Issue.4 , pp. 2038-2044
    • Wilkinson, W.A.1    Cox, M.D.2
  • 8
  • 10
    • 0034171498 scopus 로고    scopus 로고
    • Application of multiresolution signal decomposition for monitoring short-duration variations in distribution systems
    • Gaouda A M, Salama M M A, Sultan M R, et al. Application of multiresolution signal decomposition for monitoring short-duration variations in distribution systems [J]. IEEE Trans. on Power Delivery, 2000, 15(2): 478-485.
    • (2000) IEEE Trans. on Power Delivery , vol.15 , Issue.2 , pp. 478-485
    • Gaouda, A.M.1    Salama, M.M.A.2    Sultan, M.R.3
  • 11
    • 0026763601 scopus 로고
    • Modeling of metal oxide surge arresters
    • IEEE Working Group 3.4.11 of Surge Protective Devices Committee
    • IEEE Working Group 3.4.11 of Surge Protective Devices Committee. Modeling of metal oxide surge arresters [J]. IEEE Trans. on Power Delivery, 1992, 7(1): 302-309.
    • (1992) IEEE Trans. on Power Delivery , vol.7 , Issue.1 , pp. 302-309


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.