1
-
-
0015689455
-
Technique for studying the sample volume of ultrasonic Doppler devices
-
Baker, D. W., and Yates, W. G. (1973). "Technique for studying the sample volume of ultrasonic Doppler devices," Med. Biol. Eng. 11, 766-770.
-
(1973)
Med. Biol. Eng.
, vol.11
, pp. 766-770
-
-
Baker, D.W.1
Yates, W.G.2
-
2
-
-
0032917608
-
A solution to diffraction biases in sonoelasticity: The acoustic impulse technique
-
Catheline, S., Wu, F., and Fink, M. (1999). "A solution to diffraction biases in sonoelasticity: The acoustic impulse technique," J. Acoust. Soc. Am. 105, 2941-2950.
-
(1999)
J. Acoust. Soc. Am.
, vol.105
, pp. 2941-2950
-
-
Catheline, S.1
Wu, F.2
Fink, M.3
-
3
-
-
0027432703
-
Radiation pattern of a focused transducer: A numerically convergent solution
-
Chen, X., Schwarz, K. Q., and Parker, K. J. (1993). "Radiation pattern of a focused transducer: A numerically convergent solution," J. Acoust. Soc. Am. 94, 2979-2991.
-
(1993)
J. Acoust. Soc. Am.
, vol.94
, pp. 2979-2991
-
-
Chen, X.1
Schwarz, K.Q.2
Parker, K.J.3
-
4
-
-
0023104542
-
Automated noninvasive motion measurement of auditory organs in fish using ultrasound
-
Cox, M., and Rogers, P. H. (1987). "Automated noninvasive motion measurement of auditory organs in fish using ultrasound," J. Vib. Acoustics, Stress, Rel. Des. 109, 55-59.
-
(1987)
J. Vib. Acoustics, Stress, Rel. Des.
, vol.109
, pp. 55-59
-
-
Cox, M.1
Rogers, P.H.2
-
7
-
-
0033813113
-
A mathematical analysis of the peripheral auditory system mechanics in the goldfish (Carassius auratus)
-
Finneran, J. J., and Hastings, M. C. (2000). "A mathematical analysis of the peripheral auditory system mechanics in the goldfish (Carassius auratus)," J. Acoust. Soc. Am. 108, 1308-1321.
-
(2000)
J. Acoust. Soc. Am.
, vol.108
, pp. 1308-1321
-
-
Finneran, J.J.1
Hastings, M.C.2
-
8
-
-
0023312048
-
A pulsed Doppler ultrasonics system for making noninvasive measurements of the mechanical properties of soft tissues
-
Krouskop, T. A., Doughtery, D. R., and Levinson, S. F. (1987). "A pulsed Doppler ultrasonics system for making noninvasive measurements of the mechanical properties of soft tissues," J. Rehab. Res. Biol. 14, 1-8.
-
(1987)
J. Rehab. Res. Biol.
, vol.14
, pp. 1-8
-
-
Krouskop, T.A.1
Doughtery, D.R.2
Levinson, S.F.3
-
9
-
-
0000311357
-
Sono-elasticity: Medical elasticity images derived from ultrasound signals in mechanically vibrated targets
-
Plenum, New York
-
Lerner, R. M., Parker, K. J., Holen, J., Gramiak, R., and Waag, R. C. (1998). "Sono-elasticity: Medical elasticity images derived from ultrasound signals in mechanically vibrated targets," Acoustical Imaging Vol. 19, Proc. 16th Int. Symp. (Plenum, New York), pp. 317-327.
-
(1998)
Acoustical Imaging Vol. 19, Proc. 16th Int. Symp.
, vol.19
, pp. 317-327
-
-
Lerner, R.M.1
Parker, K.J.2
Holen, J.3
Gramiak, R.4
Waag, R.C.5
-
10
-
-
33646651501
-
Measurement of the vibrational response of porcine lungs to low-frequency underwater sound
-
Lewis, T. N., Martin, J. S., and Rogers, P. H. (1994). "Measurement of the vibrational response of porcine lungs to low-frequency underwater sound," J. Acoust. Soc. Am. 95, 2830(A).
-
(1994)
J. Acoust. Soc. Am.
, vol.95
, pp. 2830
-
-
Lewis, T.N.1
Martin, J.S.2
Rogers, P.H.3
-
11
-
-
0038097791
-
Low-frequency response of the submerged human lung
-
Martin, J. S., Rogers, P. H., Cudahy, E. A., and Hanson, E. L. (2000). "Low-frequency response of the submerged human lung," J. Acoust. Soc. Am. 107, 2813(A).
-
(2000)
J. Acoust. Soc. Am.
, vol.107
, pp. 2813
-
-
Martin, J.S.1
Rogers, P.H.2
Cudahy, E.A.3
Hanson, E.L.4
-
12
-
-
0001148412
-
On musical air bubbles and the sounds of running water
-
Minnaert, M. (1933). "On musical air bubbles and the sounds of running water," Philos. Mag. Ser. 7 16, 235-248.
-
(1933)
Philos. Mag. Ser. 7
, vol.16
, pp. 235-248
-
-
Minnaert, M.1
-
13
-
-
0028439396
-
Internal displacement and strain imaging using ultrasonic speckle tracking
-
O'Donnell, M., Skovorada, A. R., Shapo, B. M., and Emalianov, S. Y. (1994). "Internal displacement and strain imaging using ultrasonic speckle tracking," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 41., 314-325.
-
(1994)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.41
, pp. 314-325
-
-
O'Donnell, M.1
Skovorada, A.R.2
Shapo, B.M.3
Emalianov, S.Y.4
-
14
-
-
0025806883
-
Elastography: A quantitative method for imaging the elasticity of biological tissues
-
Ophir, J., Cespedes, I., Ponnekanti, H., Yazdi, Y., and Li, X. (1991). "Elastography: A quantitative method for imaging the elasticity of biological tissues," Ultrason. Imaging 13, 111-134.
-
(1991)
Ultrason. Imaging
, vol.13
, pp. 111-134
-
-
Ophir, J.1
Cespedes, I.2
Ponnekanti, H.3
Yazdi, Y.4
Li, X.5
-
15
-
-
33646639497
-
-
(1989) "Noninvasive vibration measurement system and method for measuring amplitude of vibration of tissue in an object being investigated," U.S. Patent No. 4,819,643
-
Rogers, P. H., and Hastings, M. C. (1989). "Noninvasive vibration measurement system and method for measuring amplitude of vibration of tissue in an object being investigated," U.S. Patent No. 4,819,643.
-
-
-
Rogers, P.H.1
Hastings, M.C.2
-
17
-
-
0004181365
-
-
Mini-Circuits, Brooklyn, NY
-
Scientific Components (1992). RF/IF Designer's Handbook (Mini-Circuits, Brooklyn, NY).
-
(1992)
RF/IF Designer's Handbook
-
-
-
18
-
-
0034130870
-
Three-dimensional sonoelastography:principles and practices
-
Taylor, L. S., Porter, B. C., Rubens, D. J., and Parker, K. J. (2000). "Three-dimensional sonoelastography:principles and practices," Phys. Med. Biol. 45, 1477-1494.
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 1477-1494
-
-
Taylor, L.S.1
Porter, B.C.2
Rubens, D.J.3
Parker, K.J.4
-
20
-
-
0017933021
-
Observations of the propagation of very short ultrasonic pulses and their reflection by small targets
-
Weight, J. P., and Hayman, A. J. (1978). "Observations of the propagation of very short ultrasonic pulses and their reflection by small targets," J. Acoust. Soc. Am. 63, 396-404.
-
(1978)
J. Acoust. Soc. Am.
, vol.63
, pp. 396-404
-
-
Weight, J.P.1
Hayman, A.J.2
-
21
-
-
0025402182
-
Ultrasonic imaging of internal vibration of soft tissue under forced vibration
-
Yamakoshi, Y., Sato, J., and Sato, T. (1990). "Ultrasonic imaging of internal vibration of soft tissue under forced vibration," IEEE Trans. Ultrason. Ferroelectr. Freq. Control 37, 45-53.
-
(1990)
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
, vol.37
, pp. 45-53
-
-
Yamakoshi, Y.1
Sato, J.2
Sato, T.3
|