1
-
-
2942724766
-
'Load transducers'
-
Berme, N., and Cappozzo, A. (Eds): (Bertec, Washington, 1990)
-
Berme, N. (1990): 'Load transducers', in Berme, N., and Cappozzo, A. (Eds): 'Biomechanics of human movement, applications in rehabilitation, sports and ergonomics' (Bertec, Washington, 1990), pp. 140-149
-
(1990)
'Biomechanics of Human Movement, Applications in Rehabilitation, Sports and Ergonomics'
, pp. 140-149
-
-
Berme, N.1
-
2
-
-
0025184607
-
'Accuracy of determining the point of force application with piezoelectric force plates'
-
Bobbert, M. F., and Schamhardt, H. C. (1990): 'Accuracy of determining the point of force application with piezoelectric force plates', J. Biomech., 23, pp. 705-710
-
(1990)
J. Biomech.
, vol.23
, pp. 705-710
-
-
Bobbert, M.F.1
Schamhardt, H.C.2
-
3
-
-
0033653405
-
'A quality control procedure for force platform'
-
Browne, J., and O'Hare, N. (2000): 'A quality control procedure for force platform', Physiol. Meas., 21, pp. 515-524
-
(2000)
Physiol. Meas.
, vol.21
, pp. 515-524
-
-
Browne, J.1
O'Hare, N.2
-
4
-
-
26744458290
-
'Standards for instrumentation and specifications'
-
Technical Report, AIM Project A2002
-
Camarc II (1994): 'Standards for instrumentation and specifications', Technical Report, AIM Project A2002
-
(1994)
-
-
Camarc, I.I.1
-
5
-
-
0030174554
-
'Optimization and smoothing techniques in movement analysis'
-
Cappello, A., La Palombara, P. F., and Leardini, A. (1996): 'Optimization and smoothing techniques in movement analysis', Int. J. Biomed. Comput., 41, pp. 137-151
-
(1996)
Int. J. Biomed. Comput.
, vol.41
, pp. 137-151
-
-
Cappello, A.1
La Palombara, P.F.2
Leardini, A.3
-
6
-
-
0021200788
-
'Gait analysis methodology'
-
Cappozzo, A. (1984): 'Gait analysis methodology', Hum. Mov. Sci., 2, pp. 27-50
-
(1984)
Hum. Mov. Sci.
, vol.2
, pp. 27-50
-
-
Cappozzo, A.1
-
7
-
-
0036890017
-
'Do strain gauge force platforms need in situ correction?'
-
Chockalingam, N., Giagas, G., and Iossifidou, A. (2002): 'Do strain gauge force platforms need in situ correction?', Gait Posture, 16, pp. 233-237
-
(2002)
Gait Posture
, vol.16
, pp. 233-237
-
-
Chockalingam, N.1
Giagas, G.2
Iossifidou, A.3
-
9
-
-
2942719184
-
'Six-component strain-gauge balances for large wind tunnels'
-
Dubois, M. (1981): 'Six-component strain-gauge balances for large wind tunnels', Proc. Soc. Exp. Stress Anal., 38, pp. 401-407
-
(1981)
Proc. Soc. Exp. Stress Anal.
, vol.38
, pp. 401-407
-
-
Dubois, M.1
-
10
-
-
0034282138
-
'A prototype system for testing force platform dynamic performance'
-
Fairburn, P. S., Palmer, R., Whybrow, J., Fielden, S., and Jones, S. (2000): 'A prototype system for testing force platform dynamic performance', Gait Posture, 12, pp. 25-33
-
(2000)
Gait Posture
, vol.12
, pp. 25-33
-
-
Fairburn, P.S.1
Palmer, R.2
Whybrow, J.3
Fielden, S.4
Jones, S.5
-
11
-
-
0030651564
-
'Quality framework for force plate testing'
-
Fleming, H. E., Hall, M. G., Dolan, M. J., and Paul, J. P. (1997): 'Quality framework for force plate testing', Proc. Inst. Mech. Eng. (H), 211, pp. 213-219
-
(1997)
Proc. Inst. Mech. Eng. (H)
, vol.211
, pp. 213-219
-
-
Fleming, H.E.1
Hall, M.G.2
Dolan, M.J.3
Paul, J.P.4
-
12
-
-
0030878009
-
'A new testing rig for force platform calibration and accuracy tests'
-
Gill, H. S., and O'Connor, J. J. (1997): 'A new testing rig for force platform calibration and accuracy tests', Gait Posture, 5, pp. 228-232
-
(1997)
Gait Posture
, vol.5
, pp. 228-232
-
-
Gill, H.S.1
O'Connor, J.J.2
-
13
-
-
0019257008
-
'A calibration procedure of a new platform'
-
Gola, M. M. (1980): 'A calibration procedure of a new platform', Acta Orthop. Belg., 46, pp. 522-533
-
(1980)
Acta Orthop. Belg.
, vol.46
, pp. 522-533
-
-
Gola, M.M.1
-
14
-
-
0030152780
-
'Static in situ calibration of force plates'
-
Hall, M. G., Fleming, H. E., Dolan, M. J., Millbank, S. F. D., and Paul, J. P. (1996): 'Static in situ calibration of force plates', J. Biomech., 29, pp. 659-665
-
(1996)
J. Biomech.
, vol.29
, pp. 659-665
-
-
Hall, M.G.1
Fleming, H.E.2
Dolan, M.J.3
Millbank, S.F.D.4
Paul, J.P.5
-
15
-
-
0042123888
-
'Influence of body segment parameters and modeling assumptions on the estimate of center of mass trajectory'
-
Lenzi, D., Capello, A., and Chiari, L. (2003): 'Influence of body segment parameters and modeling assumptions on the estimate of center of mass trajectory', J. Biomech., 36, pp. 1335-1341
-
(2003)
J. Biomech.
, vol.36
, pp. 1335-1341
-
-
Lenzi, D.1
Capello, A.2
Chiari, L.3
-
16
-
-
0027768041
-
'An investigation of the accuracy in measuring the body centre of pressure in a standing posture with a force plate'
-
Mita, K., Akataki, K., Itoh, K., Nogami, H., Katoh, R., Ninomi, S., Watanabe, M., and Suzuki, N. (1993): 'An investigation of the accuracy in measuring the body centre of pressure in a standing posture with a force plate', Front. Med. Biol. Eng., 5, pp. 201-213
-
(1993)
Front. Med. Biol. Eng.
, vol.5
, pp. 201-213
-
-
Mita, K.1
Akataki, K.2
Itoh, K.3
Nogami, H.4
Katoh, R.5
Ninomi, S.6
Watanabe, M.7
Suzuki, N.8
-
17
-
-
0032829679
-
'Parameters influencing the accuracy of the point of force application determined with piezoelectric force plates'
-
Schmiedmayer, H. B., and Kastner, J. (1999): 'Parameters influencing the accuracy of the point of force application determined with piezoelectric force plates', J. Biomech., 32, pp. 1237-1242
-
(1999)
J. Biomech.
, vol.32
, pp. 1237-1242
-
-
Schmiedmayer, H.B.1
Kastner, J.2
-
18
-
-
0033765323
-
'Enhancements in the accuracy of the center of pressure (COP) determined with piezoelectric force plates are dependent on the load distribution'
-
Schmiedmayer, H. B., and Kastner, J. (2000): 'Enhancements in the accuracy of the center of pressure (COP) determined with piezoelectric force plates are dependent on the load distribution', ASME J. Biomech. Eng., 122, pp. 523-527
-
(2000)
ASME J. Biomech. Eng.
, vol.122
, pp. 523-527
-
-
Schmiedmayer, H.B.1
Kastner, J.2
|