메뉴 건너뛰기




Volumn 81, Issue 6, 2004, Pages 471-477

Testing of a dual-mode microwave care regimen for hydrogel lenses

Author keywords

Disinfecting; Hydrogel contact lenses; Microbiology; Microwave; Patient trials

Indexed keywords

CONTACT LENSES; HYDROGELS; MICROWAVE DEVICES; OPTOMETERS; PATIENT MONITORING; SURFACE ACTIVE AGENTS;

EID: 2942657467     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.opx.0000135100.09288.8f     Document Type: Article
Times cited : (6)

References (16)
  • 1
    • 2942639874 scopus 로고    scopus 로고
    • note
    • Association of Contact Lens Manufacturers (UK) Market Trends 2002, unpublished internal bulletin.
  • 2
    • 0034861135 scopus 로고    scopus 로고
    • Clinical trial of a patient-operated microwave care system for hydrogel contact lenses
    • Crabbe A, Thompson P. Clinical trial of a patient-operated microwave care system for hydrogel contact lenses. Optom Vis Sci 2001;78:605-9.
    • (2001) Optom Vis Sci , vol.78 , pp. 605-609
    • Crabbe, A.1    Thompson, P.2
  • 7
    • 0002760251 scopus 로고    scopus 로고
    • Stability of Crofilcon and Polymacon (clear and tinted) contact lenses after microwave irradiation
    • Quesnel N, Simonet P, Giasson C. Stability of Crofilcon and Polymacon (clear and tinted) contact lenses after microwave irradiation. J Br Contact Lens Assoc 1996;19:49-54.
    • (1996) J Br Contact Lens Assoc , vol.19 , pp. 49-54
    • Quesnel, N.1    Simonet, P.2    Giasson, C.3
  • 8
    • 0034877512 scopus 로고    scopus 로고
    • Effects of microwave irradiation on the parameters of hydrogel contact lenses
    • Crabbe A, Thompson P. Effects of microwave irradiation on the parameters of hydrogel contact lenses. Optom Vis Sci 2001;78:610-5.
    • (2001) Optom Vis Sci , vol.78 , pp. 610-615
    • Crabbe, A.1    Thompson, P.2
  • 13
    • 0027250973 scopus 로고
    • Acanthamoeba trophozoite and cyst adherence to four types of soft contact lens and removal by cleaning agents
    • Kilvington S. Acanthamoeba trophozoite and cyst adherence to four types of soft contact lens and removal by cleaning agents. Eye 1993;7:535-8.
    • (1993) Eye , vol.7 , pp. 535-538
    • Kilvington, S.1
  • 15
    • 0018867814 scopus 로고
    • Effects of long-term heat disinfection on Soflens (polymacon) contact lenses
    • Riedhammer TM, Falcetta JJ. Effects of long-term heat disinfection on Soflens (polymacon) contact lenses. J Am Optom Assoc 1980;51:287-9.
    • (1980) J Am Optom Assoc , vol.51 , pp. 287-289
    • Riedhammer, T.M.1    Falcetta, J.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.