메뉴 건너뛰기




Volumn 18, Issue 6, 2004, Pages 351-358

Sensor systems for use in reinforced concrete structures

Author keywords

Concrete structures; Cover zone; Durability; Electrical methods; Monitoring; Reinforcement corrosion; Sensors

Indexed keywords

CONCRETE CONSTRUCTION; CORROSION; DURABILITY; ELECTRIC CONDUCTIVITY; ENVIRONMENTAL IMPACT; HYDRATION; MONITORING; SENSORS;

EID: 2942638066     PISSN: 09500618     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.conbuildmat.2004.03.008     Document Type: Review
Times cited : (140)

References (26)
  • 2
    • 0342771318 scopus 로고    scopus 로고
    • Eurocode 2-Innovations in design and construction of concrete structures
    • R.K. Dhir, M.R. Jones (eds.), London: Thomas Telford Ltd., September
    • Litzner, H.U. Eurocode 2-Innovations in design and construction of concrete structures, in: R.K. Dhir, M.R. Jones (eds.) Proceedings Creating with Concrete Conference, London: Thomas Telford Ltd., September 1999; pp. 193-209.
    • (1999) Proceedings Creating with Concrete Conference , pp. 193-209
    • Litzner, H.U.1
  • 3
    • 0004198660 scopus 로고    scopus 로고
    • Report BE95-1347/R4-5, December (ISBN 90 376 0444 7)
    • European Union - Brite EuRam III, Duracrete - Modelling of degradation, Report BE95-1347/R4-5, December 1998, p. 174, (ISBN 90 376 0444 7).
    • (1998) Duracrete - Modelling of Degradation , pp. 174
  • 5
    • 2942672227 scopus 로고    scopus 로고
    • CEN, Brussels, EN 2000 206-1
    • European Committee for Standardization (CEN), Concrete: Performance, Production and Conformity. CEN, Brussels, EN 2000 206-1, 2000, pp. 17-18.
    • (2000) Concrete: Performance, Production and Conformity , pp. 17-18
  • 6
    • 0342336351 scopus 로고    scopus 로고
    • Instrumentation of structures with sensors - Why and How?
    • R.K. Dhir, M.R. Jones (eds.), London: E&FN Spon, June
    • Schießl, P., Raupach, M., Instrumentation of Structures with Sensors - Why and How? in: R.K. Dhir, M.R. Jones (eds.) Proceedings Concrete in the Service of Mankind Conference, London: E&FN Spon, June 1996; pp. 1-15.
    • (1996) Proceedings Concrete in the Service of Mankind Conference , pp. 1-15
    • Schießl, P.1    Raupach, M.2
  • 7
    • 0001958263 scopus 로고
    • Monitoring the corrosion of reinforcing steel
    • May
    • Langford P., Broomfield J.P. Monitoring the corrosion of reinforcing steel. Constr Repair. May 1987;32-36.
    • (1987) Constr Repair , pp. 32-36
    • Langford, P.1    Broomfield, J.P.2
  • 8
    • 0024082455 scopus 로고
    • Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types
    • Alonso C., Andrade C., Gonzalez J.A. Relation between resistivity and corrosion rate of reinforcements in carbonated mortar made with several cement types. Cem Concr Res. 8:(5):1988;687-698.
    • (1988) Cem Concr Res , vol.8 , Issue.5 , pp. 687-698
    • Alonso, C.1    Andrade, C.2    Gonzalez, J.A.3
  • 9
    • 0024914217 scopus 로고
    • Steel in concrete: Part I A review of the electrochemical and thermodynamic aspects
    • Sagoe-Crentsil K.K., Glasser F.P. Steel in concrete: Part I A review of the electrochemical and thermodynamic aspects. Mag Conc Res. 41:(149):1989;205-212.
    • (1989) Mag Conc Res , vol.41 , Issue.149 , pp. 205-212
    • Sagoe-Crentsil, K.K.1    Glasser, F.P.2
  • 10
    • 0027557534 scopus 로고
    • Influence of degree of saturation on the resistivity of concrete and the corrosion rate of steel reinforcement
    • Lopez W., Gonzalez J.A. Influence of degree of saturation on the resistivity of concrete and the corrosion rate of steel reinforcement. Cem Concr Res. 23:(2):1993;368-376.
    • (1993) Cem Concr Res , vol.23 , Issue.2 , pp. 368-376
    • Lopez, W.1    Gonzalez, J.A.2
  • 12
    • 0029369337 scopus 로고
    • Properties of concrete in the cover zone: Developments in monitoring techniques
    • McCarter W.J., Emerson M., Ezirim H. Properties of concrete in the cover zone: developments in monitoring techniques. Mag Concr Res. 47:(172):1995;243- 251.
    • (1995) Mag Concr Res , vol.47 , Issue.172 , pp. 243-251
    • Mccarter, W.J.1    Emerson, M.2    Ezirim, H.3
  • 13
    • 0034335038 scopus 로고    scopus 로고
    • Monitoring water and ionic penetration into cover-zone concrete
    • McCarter W.J., Chrisp T.M. Monitoring water and ionic penetration into cover-zone concrete. ACI Mater J. 97:(6):2000;668-674.
    • (2000) ACI Mater J , vol.97 , Issue.6 , pp. 668-674
    • Mccarter, W.J.1    Chrisp, T.M.2
  • 14
    • 0035283470 scopus 로고    scopus 로고
    • Near surface sensors for condition monitoring of cover-zone concrete
    • McCarter W.J., Chrisp T.M., Butler A., Basheer P.A.M. Near surface sensors for condition monitoring of cover-zone concrete. Constr Build Mater. 15:(2-3):2001;115-124.
    • (2001) Constr Build Mater , vol.15 , Issue.2-3 , pp. 115-124
    • Mccarter, W.J.1    Chrisp, T.M.2    Butler, A.3    Basheer, P.A.M.4
  • 15
    • 0033200784 scopus 로고    scopus 로고
    • Performance of steel reinforcement in Portland cement and high volume fly ash concretes exposed to chloride solution
    • Ping G., Beaudoin J.J., Zhang M., Malhotra V.M. Performance of steel reinforcement in Portland cement and high volume fly ash concretes exposed to chloride solution. ACI Mater J. 96:(5):1999;551-558.
    • (1999) ACI Mater J , vol.96 , Issue.5 , pp. 551-558
    • Ping, G.1    Beaudoin, J.J.2    Zhang, M.3    Malhotra, V.M.4
  • 16
    • 0035283437 scopus 로고    scopus 로고
    • On-site measurements of corrosion rate of reinforcements
    • Andrade C., Alonso C. On-site measurements of corrosion rate of reinforcements. Constr Build Mater. 15:(2-3):2001;141-145.
    • (2001) Constr Build Mater , vol.15 , Issue.2-3 , pp. 141-145
    • Andrade, C.1    Alonso, C.2
  • 17
    • 85111751831 scopus 로고    scopus 로고
    • Monitoring corrosion risk in concrete structures - R eview of 10 years experience and new developments
    • Barcelona, SP-192, June
    • Schießl, P., Raupach, M., Monitoring corrosion risk in concrete structures - review of 10 years experience and new developments Proceedings of the 5th CANMET/ACI Int. Conference on Durability of Concrete, Barcelona, SP-192, Vol. 1, June 2000; pp. 19-34.
    • (2000) Proceedings of the 5th CANMET/ACI Int. Conference on Durability of Concrete , vol.1 , pp. 19-34
    • Schießl, P.1    Raupach, M.2
  • 18
    • 0019558127 scopus 로고
    • The conduction of electricity through concrete
    • Whittington H.W., McCarter W.J., Forde M.C. The conduction of electricity through concrete. Mag Concr Res. 33:(114):1981;48-60.
    • (1981) Mag Concr Res , vol.33 , Issue.114 , pp. 48-60
    • Whittington, H.W.1    Mccarter, W.J.2    Forde, M.C.3
  • 19
    • 0030247344 scopus 로고    scopus 로고
    • Properties of concrete in the cover zone: Water penetration, sorptivity and ionic ingress
    • McCarter W.J., Ezirim H., Emerson M. Properties of concrete in the cover zone: water penetration, sorptivity and ionic ingress. Mag Concr Res. 48:(176):1996;149-156.
    • (1996) Mag Concr Res , vol.48 , Issue.176 , pp. 149-156
    • Mccarter, W.J.1    Ezirim, H.2    Emerson, M.3
  • 20
    • 0033200788 scopus 로고    scopus 로고
    • Measurement of concrete resistivity for assessment of corrosion severity of steel using Wenner technique
    • Gowers K.R., Millard S.G. Measurement of concrete resistivity for assessment of corrosion severity of steel using Wenner technique. ACI Mater J. 96:(5):1999;536-541.
    • (1999) ACI Mater J , vol.96 , Issue.5 , pp. 536-541
    • Gowers, K.R.1    Millard, S.G.2
  • 21
    • 0024768617 scopus 로고
    • Dependence of electrical impedance of cement-based materials on their moisture condition
    • McCarter W.J., Garvin S. Dependence of electrical impedance of cement-based materials on their moisture condition. J Phys D: Appl Phys. 22:1989;1773-1776.
    • (1989) J Phys D: Appl Phys , vol.22 , pp. 1773-1776
    • Mccarter, W.J.1    Garvin, S.2
  • 22
    • 0036524385 scopus 로고    scopus 로고
    • Standardization, to a reference temperature of 25 °C, of electrical resistivity for mortars and concretes in saturated or isolated conditions
    • Castellote M., Andrade C., Alonso M.C. Standardization, to a reference temperature of 25 °C, of electrical resistivity for mortars and concretes in saturated or isolated conditions. ACI Mater J. 99:(2):2002;119-128.
    • (2002) ACI Mater J , vol.99 , Issue.2 , pp. 119-128
    • Castellote, M.1    Andrade, C.2    Alonso, M.C.3
  • 23
    • 0343641570 scopus 로고    scopus 로고
    • Efficacy of hydrophobic treatments for concrete and their influence on moisture movement within the cover-zone
    • Prague, September (ISBN80-01-01838-5)
    • Watson, D, McCarter, W.J. Efficacy of hydrophobic treatments for concrete and their influence on moisture movement within the cover-zone, International Conference on New requirements for Materials and Structures, Prague, September 1998, pp. 23-28 (ISBN80-01-01838-5).
    • (1998) International Conference on New Requirements for Materials and Structures , pp. 23-28
    • Watson, D.1    Mccarter, W.J.2
  • 24
    • 2942639666 scopus 로고    scopus 로고
    • Smart structures: Integrated monitoring systems for durability assessment of concrete structures
    • April
    • Smart Structures: integrated monitoring systems for durability assessment of concrete structures, FORCE Institute (Denmark) Newsletter, No. 1, April 2000; pp. 1-2.
    • (2000) FORCE Institute (Denmark) Newsletter , Issue.1 , pp. 1-2
  • 25
    • 2942635225 scopus 로고    scopus 로고
    • New standard for service-life planning
    • October
    • Doran D. New standard for service-life planning. Struct Eng. 78:(19):October 2000;8.
    • (2000) Struct Eng , vol.78 , Issue.19 , pp. 8
    • Doran, D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.