메뉴 건너뛰기




Volumn 30, Issue 6, 2004, Pages 1320-1325

Retrospective analysis of actual LASIK flap diameter compared with microkeratome ring size performed by different surgeons

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DEVICE; HUMAN; INTERMETHOD COMPARISON; KERATOMETRY; KERATOMILEUSIS; MICROKERATOMA; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; SKIN FLAP; STATISTICAL ANALYSIS; STATISTICAL SIGNIFICANCE; SURGEON;

EID: 2942587333     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2003.10.030     Document Type: Article
Times cited : (2)

References (12)
  • 1
    • 0035989292 scopus 로고    scopus 로고
    • Factors that affect flap thickness with the Hansatome microkeratome
    • Gailitis R.P., Lagzdins M. Factors that affect flap thickness with the Hansatome microkeratome. J Refract Surg. 18:2002;439-443
    • (2002) J Refract Surg , vol.18 , pp. 439-443
    • Gailitis, R.P.1    Lagzdins, M.2
  • 2
    • 0036579844 scopus 로고    scopus 로고
    • Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes
    • Shemesh G., Dotan G., Lipshitz I. Predictability of corneal flap thickness in laser in situ keratomileusis using three different microkeratomes. J Refract Surg. 18:2002;S347-S351
    • (2002) J Refract Surg , vol.18 , pp. 347-S351
    • Shemesh, G.1    Dotan, G.2    Lipshitz, I.3
  • 3
    • 0036271439 scopus 로고    scopus 로고
    • In vivo confocal microscopy through-focusing to measure corneal flap thickness after laser in situ keratomileusis
    • Gokmen F., Jester J.V., Petroll W.M., et al. In vivo confocal microscopy through-focusing to measure corneal flap thickness after laser in situ keratomileusis. J Cataract Refract Surg. 28:2002;962-970
    • (2002) J Cataract Refract Surg , vol.28 , pp. 962-970
    • Gokmen, F.1    Jester, J.V.2    Petroll, W.M.3
  • 5
    • 0035468467 scopus 로고    scopus 로고
    • Flap analysis: Critical point in laser in situ keratomileusis
    • Srivannaboon S. Flap analysis. critical point in laser in situ keratomileusis J Med Assoc Thai. 84:2001;1317-1320
    • (2001) J Med Assoc Thai , vol.84 , pp. 1317-1320
    • Srivannaboon, S.1
  • 6
    • 0035081949 scopus 로고    scopus 로고
    • Evaluation of the reliability of the Nidek MK-2000 microkeratome for laser in situ keratomileusis
    • Naripthaphan P., Vongthongsri A. Evaluation of the reliability of the Nidek MK-2000 microkeratome for laser in situ keratomileusis. J Refract Surg. 17:2001;S255-S258
    • (2001) J Refract Surg , vol.17 , pp. 255-S258
    • Naripthaphan, P.1    Vongthongsri, A.2
  • 7
    • 0034537228 scopus 로고    scopus 로고
    • Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome
    • Yildirim R., Aras C., Ozdamar A., et al. Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome. J Cataract Refract Surg. 26:2000;1729-1732
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1729-1732
    • Yildirim, R.1    Aras, C.2    Ozdamar, A.3
  • 8
    • 0033659218 scopus 로고    scopus 로고
    • The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis
    • Durairaj V.D., Balentine J., Kouyoumdjian G., et al. The predictability of corneal flap thickness and tissue laser ablation in laser in situ keratomileusis. Ophthalmology. 107:2000;2140-2143
    • (2000) Ophthalmology , vol.107 , pp. 2140-2143
    • Durairaj, V.D.1    Balentine, J.2    Kouyoumdjian, G.3
  • 9
    • 0033959899 scopus 로고    scopus 로고
    • Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome
    • Behrens A., Seitz B., Langenbucher A., et al. Evaluation of corneal flap dimensions and cut quality using the Automated Corneal Shaper microkeratome. J Refract Surg. 16:2000;83-89
    • (2000) J Refract Surg , vol.16 , pp. 83-89
    • Behrens, A.1    Seitz, B.2    Langenbucher, A.3
  • 10
    • 0033957533 scopus 로고    scopus 로고
    • Experimental evaluation of two current-generation automated microkeratomes: The Hansatome and the Supratome
    • Behrens A., Langenbucher A., Kus M.M., et al. Experimental evaluation of two current-generation automated microkeratomes. the Hansatome and the Supratome Am J Ophthalmol. 129:2000;59-67
    • (2000) Am J Ophthalmol , vol.129 , pp. 59-67
    • Behrens, A.1    Langenbucher, A.2    Kus, M.M.3
  • 12
    • 0034198992 scopus 로고    scopus 로고
    • Corneal flap dimensions in laser in situ keratomileusis using the Innovatome automatic microkeratome
    • Choi Y.I., Park S.J., Song B.J. Corneal flap dimensions in laser in situ keratomileusis using the Innovatome automatic microkeratome. Korean J Ophthalmol. 14:2000;7-11
    • (2000) Korean J Ophthalmol , vol.14 , pp. 7-11
    • Choi, Y.I.1    Park, S.J.2    Song, B.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.