메뉴 건너뛰기




Volumn 22, Issue 2, 2004, Pages 611-618

Proton MRI of metabolically produced H217O using an efficient 17O2 delivery system

Author keywords

17O MRS; 17O2 inhalation; CMRO2; Cortical oxidative metabolism; fMRI; Indirect 17O MRI; Proton T1 weighted imaging; Rat brain mapping

Indexed keywords

OXYGEN 17; WATER;

EID: 2942563950     PISSN: 10538119     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.neuroimage.2004.02.024     Document Type: Article
Times cited : (28)

References (19)
  • 2
    • 0028952012 scopus 로고
    • Micropore membrane inlet mass-spectrometer probes suitable for measurement of tissue surface gas tensions
    • Baumgardner J.E., Quinn J.A., Neufeld G.R. Micropore membrane inlet mass-spectrometer probes suitable for measurement of tissue surface gas tensions. J. Mass Spectrom. 30:1995;563-571
    • (1995) J. Mass Spectrom. , vol.30 , pp. 563-571
    • Baumgardner, J.E.1    Quinn, J.A.2    Neufeld, G.R.3
  • 6
  • 7
    • 0023918626 scopus 로고
    • Improved sensitivity of proton MR to oxygen-17 as a contrast agent using fast imaging: Detection in brain
    • Hopkins A.L., Haacke E.M., Tkach J., Barr R.G., Bratton C.B. Improved sensitivity of proton MR to oxygen-17 as a contrast agent using fast imaging: detection in brain. Magn. Reson. Med. 7:1988;222-229
    • (1988) Magn. Reson. Med. , vol.7 , pp. 222-229
    • Hopkins, A.L.1    Haacke, E.M.2    Tkach, J.3    Barr, R.G.4    Bratton, C.B.5
  • 10
    • 2442678123 scopus 로고
    • H.J. Lowe, J.A. Aldrete, & R.W. Virtue. New York: Grune and Stratton
    • Lowe H.J., Aldrete J.A., Virtue R.W. Low Flow and Closed System Anesthesia. 1979;Grune and Stratton, New York
    • (1979) Low Flow and Closed System Anesthesia
  • 14
    • 0028081801 scopus 로고
    • 17O with potential applications for functional MRI
    • 17O with potential applications for functional MRI. Magn. Reson. Med. 32:1994;789-793
    • (1994) Magn. Reson. Med. , vol.32 , pp. 789-793
    • Ronen, I.1    Navon, G.2
  • 18
    • 0033962824 scopus 로고    scopus 로고
    • Absolute measurements of water content using magnetic resonance imaging: Preliminary findings in an in vivo focal ischemic rat model
    • Venkatesan R., Lin W., Gurleyik K., He Y.Y., Paczynski R.P., Powers W.J., Hsu C.Y. Absolute measurements of water content using magnetic resonance imaging: preliminary findings in an in vivo focal ischemic rat model. Magn. Reson. Med. 43:2000;146-150
    • (2000) Magn. Reson. Med. , vol.43 , pp. 146-150
    • Venkatesan, R.1    Lin, W.2    Gurleyik, K.3    He, Y.Y.4    Paczynski, R.P.5    Powers, W.J.6    Hsu, C.Y.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.