-
1
-
-
0034193490
-
A revolution in biological and medical sciences
-
Figeys, D.; Pinto, D. A revolution in biological and medical sciences. Anal. Chem. 2000, 72, 330A-335A.
-
(2000)
Anal. Chem.
, vol.72
-
-
Figeys, D.1
Pinto, D.2
-
2
-
-
0031752710
-
Chemiluminescence detection in integrated post-separation reactors for microchip-based capillary electrophoresis and affinity electrophoresis
-
Shakuntala, D.M.; Harrison, D.J. Chemiluminescence detection in integrated post-separation reactors for microchip-based capillary electrophoresis and affinity electrophoresis. Electrophoresis 1998, 19, 2301.
-
(1998)
Electrophoresis
, vol.19
, pp. 2301
-
-
Shakuntala, D.M.1
Harrison, D.J.2
-
3
-
-
0035076083
-
Capillary electrophoresis system with flow injection sample introduction and chemiluminescence detection on a chip platform
-
Huang, X.J.; Pu, Q.S.; Fang, Z.L. Capillary electrophoresis system with flow injection sample introduction and chemiluminescence detection on a chip platform. Analyst 2001, 126, 281-284.
-
(2001)
Analyst
, vol.126
, pp. 281-284
-
-
Huang, X.J.1
Pu, Q.S.2
Fang, Z.L.3
-
4
-
-
0033965156
-
Tris(2,2-bipyridyl)ruthenium (II) chemiluminescence in a microflow injection system for codeine determination
-
Greenway, G.M.; Nelstrop, L.J.; Port, S.N. Tris(2,2-bipyridyl)ruthenium (II) chemiluminescence in a microflow injection system for codeine determination. Anal. Chim. Acta 2000, 405, 43-50.
-
(2000)
Anal. Chim. Acta
, vol.405
, pp. 43-50
-
-
Greenway, G.M.1
Nelstrop, L.J.2
Port, S.N.3
-
5
-
-
0033994482
-
On-line monitoring of chromium(III) using a fast micromachined mixer/reactor and chemiluminescence detection
-
Xu, Y.; Bessoth, F.G.; Eijkel, J.C.T.; Manz, A. On-line monitoring of chromium(III) using a fast micromachined mixer/reactor and chemiluminescence detection. Analyst 2000, 125, 677-683.
-
(2000)
Analyst
, vol.125
, pp. 677-683
-
-
Xu, Y.1
Bessoth, F.G.2
Eijkel, J.C.T.3
Manz, A.4
-
6
-
-
0035726478
-
Development of a low-cost microfluidic capillary-electrophoresis system coupled with flow-injection and sequential-injection sample introduction
-
Fang, Z.L.; Fang, Q. Development of a low-cost microfluidic capillary-electrophoresis system coupled with flow-injection and sequential-injection sample introduction (review). Fresenius' J. Anal. Chem. 2001, 370, 978-983.
-
(2001)
Fresenius' J. Anal. Chem.
, vol.370
, pp. 978-983
-
-
Fang, Z.L.1
Fang, Q.2
-
7
-
-
0242418231
-
Miniaturized tris(2,2′-bipyfidyl) ruthenium(II) electrochemiluminescence detection cell for capillary electrophoresis and flow injection analysis
-
Liu, J.F.; Yan, J.L.; Yang, X.R.; Wang, E.K. Miniaturized tris(2,2′-bipyfidyl) ruthenium(II) electrochemiluminescence detection cell for capillary electrophoresis and flow injection analysis. Anal. Chem. 2003, 75, 3637-3642.
-
(2003)
Anal. Chem.
, vol.75
, pp. 3637-3642
-
-
Liu, J.F.1
Yan, J.L.2
Yang, X.R.3
Wang, E.K.4
-
8
-
-
0037017803
-
Chemiluminescence μTAS for the determination of atropine and pethidine
-
Paul, A.G.; Carolyn, M.; Tom, M.; Gillian, M.G. Chemiluminescence μTAS for the determination of atropine and pethidine. Talanta 2002, 56, 539-545.
-
(2002)
Talanta
, vol.56
, pp. 539-545
-
-
Paul, A.G.1
Carolyn, M.2
Tom, M.3
Gillian, M.G.4
-
9
-
-
0037457525
-
A biochemical microdevice with an integrated chemiluminescence detector
-
Anders, M.J.; Klaus, B.M.; Jörg, P.K.; Oliver, G. A biochemical microdevice with an integrated chemiluminescence detector. Sens. Actuators B 2003, 90, 15-21.
-
(2003)
Sens. Actuators B
, vol.90
, pp. 15-21
-
-
Anders, M.J.1
Klaus, B.M.2
Jörg, P.K.3
Oliver, G.4
-
10
-
-
0035356942
-
Microfluidics controlling fluids in small places
-
Polson, N.A.; Hayes, M.A. Microfluidics controlling fluids in small places. Anal. Chem. 2001, 73, 312A-319A.
-
(2001)
Anal. Chem.
, vol.73
-
-
Polson, N.A.1
Hayes, M.A.2
-
11
-
-
0000376878
-
Chemiluminescence flow system for the determination of Fe(II) and Fe(III) in water
-
Qin, W.; Zhang, Z.J.; Wang, F.C. Chemiluminescence flow system for the determination of Fe(II) and Fe(III) in water. Fresenius' Anal. Chim. 1998, 360, 130-132.
-
(1998)
Fresenius' Anal. Chim.
, vol.360
, pp. 130-132
-
-
Qin, W.1
Zhang, Z.J.2
Wang, F.C.3
-
13
-
-
2942586314
-
Determination of whole blood iron with AAS method
-
Liu, W.J. Determination of whole blood iron with AAS method. Chinese Med. Acta 1988, 6, 48-51.
-
(1988)
Chinese Med. Acta
, vol.6
, pp. 48-51
-
-
Liu, W.J.1
-
14
-
-
0005036961
-
Generating electrospray from microchip devices using electroosmotic pumping
-
Ramsey, R.S.; Ramsey, J.M. Generating electrospray from microchip devices using electroosmotic pumping. Anal. Chem. 1997, 69, 1174-1178.
-
(1997)
Anal. Chem.
, vol.69
, pp. 1174-1178
-
-
Ramsey, R.S.1
Ramsey, J.M.2
-
15
-
-
0031081614
-
Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline
-
Chiem, N.; Harrison, D.J. Microchip-based capillary electrophoresis for immunoassays: analysis of monoclonal antibodies and theophylline. Anal. Chem. 1997, 69, 373-378.
-
(1997)
Anal. Chem.
, vol.69
, pp. 373-378
-
-
Chiem, N.1
Harrison, D.J.2
-
16
-
-
0033067401
-
Characterisation of a micrototal analytical system for the determination of nitrite with spectrophotometric detection
-
Greenway, G.M.; Haswell, S.J.; Petsul, P.H. Characterisation of a micrototal analytical system for the determination of nitrite with spectrophotometric detection. Anal. Chim. Acta 1999, 387, 1-10.
-
(1999)
Anal. Chim. Acta
, vol.387
, pp. 1-10
-
-
Greenway, G.M.1
Haswell, S.J.2
Petsul, P.H.3
-
18
-
-
2942589895
-
Study on the determination of iron by differenfial potentiometric stripping analysis
-
Li, X.B.; Liang, B.; Xian, M.L. Study on the determination of iron by differenfial potentiometric stripping analysis. J. Sichuan Uni. 2001, 7, 67-70.
-
(2001)
J. Sichuan Uni.
, vol.7
, pp. 67-70
-
-
Li, X.B.1
Liang, B.2
Xian, M.L.3
|