메뉴 건너뛰기




Volumn 31, Issue 2, 2004, Pages 175-177

Transcatheter closure of a pateint foramen ovale in an adult with hypoxemia after cardiac transplantation

Author keywords

Contrast media; Echocardiography, Doppler, color; Echocardiography, transesophageal; Heart septal defects, atrial; Heart transplantation adverse effects; Hemodynamic processes; Postoperative complications

Indexed keywords

ADULT; ARTICLE; BALLOON CATHETER; CASE REPORT; CATHETERIZATION; DEVICE; FEMALE; HEART ATRIUM SEPTUM DEFECT; HEART TRANSPLANTATION; HUMAN; HYPOXEMIA; POSTOPERATIVE PERIOD; SEPTAL OCCLUSION DEVICE; SURGICAL TECHNIQUE; TRANSCATHETER CLOSURE; AGED; DOPPLER ECHOCARDIOGRAPHY; ECHOGRAPHY; HEART CATHETERIZATION; HEART SEPTUM DEFECT; RECURRENT DISEASE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 2942561972     PISSN: 07302347     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (9)
  • 2
    • 0030248085 scopus 로고    scopus 로고
    • Heart transplantation complicated by a patent foramen ovale of the recipient atrial septum
    • Yun KL, Reichenspurner H, Schmoker J, Hu B, Stinson EB. Heart transplantation complicated by a patent foramen ovale of the recipient atrial septum. Ann Thorac Surg 1996;62(3):897-9.
    • (1996) Ann Thorac Surg , vol.62 , Issue.3 , pp. 897-899
    • Yun, K.L.1    Reichenspurner, H.2    Schmoker, J.3    Hu, B.4    Stinson, E.B.5
  • 3
    • 0031264396 scopus 로고    scopus 로고
    • Patent foramen ovale presenting as refractory hypoxemia after heart transplantation
    • Ouseph R, Stoddard MF, Lederer ED. Patent foramen ovale presenting as refractory hypoxemia after heart transplantation. J Arm Soc Echocardiogr 1997;10(9):973-6.
    • (1997) J Arm Soc Echocardiogr , vol.10 , Issue.9 , pp. 973-976
    • Ouseph, R.1    Stoddard, M.F.2    Lederer, E.D.3
  • 4
    • 0030032491 scopus 로고    scopus 로고
    • Closure of a patent foramen ovale and tricuspid valve replacement after heart transplantation
    • Weston MW, Vijayanagar R, Sastry NS. Closure of a patent foramen ovale and tricuspid valve replacement after heart transplantation. Ann Thorac Surg 1996;61(2):717-9.
    • (1996) Ann Thorac Surg , vol.61 , Issue.2 , pp. 717-719
    • Weston, M.W.1    Vijayanagar, R.2    Sastry, N.S.3
  • 5
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: an autopsy study of 965 normal hearts. Mayo Clin Proc 1984;59:17-20.
    • (1984) Mayo Clin Proc , vol.59 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 6
    • 0029024221 scopus 로고
    • The incidence of patent foramen ovale in 1,000 consecutive patients. A contrast transesophageal echocardiographic study
    • Fisher DC, Fisher EA, Budd JH, Rosen SE, Goldman ME. The incidence of patent foramen ovale in 1,000 consecutive patients. A contrast transesophageal echocardiographic study. Chest 1995;107(6):1504-9.
    • (1995) Chest , vol.107 , Issue.6 , pp. 1504-1509
    • Fisher, D.C.1    Fisher, E.A.2    Budd, J.H.3    Rosen, S.E.4    Goldman, M.E.5