메뉴 건너뛰기




Volumn 26, Issue 4, 2005, Pages 301-314

A steady-state model for predicting hygrothermal conditions in beds in relation to house dust mite requirements

Author keywords

[No Author keywords available]

Indexed keywords

HOUSE DUST MITE REQUIREMENTS; HYGROTHERMAL CONDITIONS; MITE POPULATION INDEX (MPI); STEADY STATE MODEL;

EID: 29344463275     PISSN: 01436244     EISSN: None     Source Type: Journal    
DOI: 10.1191/0143624405bt137oa     Document Type: Article
Times cited : (4)

References (13)
  • 1
    • 3543035759 scopus 로고
    • Worldwide variations in the prevalance of asthma symptoms: The International Study of Asthma and Allergies in Childhood (ISAAC)
    • ISAAC Steering Committee
    • ISAAC Steering Committee. Worldwide variations in the prevalance of asthma symptoms: the International Study of Asthma and Allergies in Childhood (ISAAC). European Respiratory Journal 1988; 12: 315-35.
    • (1988) European Respiratory Journal , vol.12 , pp. 315-335
  • 3
    • 0020678201 scopus 로고
    • House dust mites and absolute indoor humidity
    • Korsgaard J. House dust mites and absolute indoor humidity. Allergy 1983; 38: 85-92.
    • (1983) Allergy , vol.38 , pp. 85-92
    • Korsgaard, J.1
  • 6
    • 0033326892 scopus 로고    scopus 로고
    • Condensation Targeter II: Modelling surface relative humidity to predict mould growth in dwellings
    • Oreszczyn T, Pretlove SEC. Condensation Targeter II: Modelling surface relative humidity to predict mould growth in dwellings. Building Serv. Eng. Res. Technol. 1999; 20: 143-53.
    • (1999) Building Serv. Eng. Res. Technol. , vol.20 , pp. 143-153
    • Oreszczyn, T.1    Pretlove, S.E.C.2
  • 8
    • 0037678095 scopus 로고
    • The effects of ventilation and building design factors on the risk of condensation and mould growth in dwellings
    • Building Research Station (BRS) CP 31/71
    • Loudon AG. The effects of ventilation and building design factors on the risk of condensation and mould growth in dwellings. Building Research Station (BRS) CP 31/71, 1971.
    • (1971)
    • Loudon, A.G.1
  • 9
    • 29344473871 scopus 로고    scopus 로고
    • Predicting relative humidity in UK dwellings
    • PhD thesis. London: University of London, March
    • Pretlove SEC. Predicting relative humidity in UK dwellings. PhD thesis. London: University of London, March 2000.
    • (2000)
    • Pretlove, S.E.C.1
  • 11
    • 0031718566 scopus 로고    scopus 로고
    • Direct measurements of temperature and humidity in dust mite microhabitats
    • Cunningham MJ. Direct measurements of temperature and humidity in dust mite microhabitats. Clinical and Experimental Allergy 1998; 28: 1104-12.
    • (1998) Clinical and Experimental Allergy , vol.28 , pp. 1104-1112
    • Cunningham, M.J.1
  • 13
    • 0012139332 scopus 로고    scopus 로고
    • Potential implications of climate change in the built environment
    • Foundation for the Built Environment (FBE), Building Research Establishment (BRE), East Kilbride
    • Graves HM, Phillipson MC. Potential implications of climate change in the built environment. Foundation for the Built Environment (FBE), Building Research Establishment (BRE), East Kilbride, 2000.
    • (2000)
    • Graves, H.M.1    Phillipson, M.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.