메뉴 건너뛰기




Volumn 46, Issue 5, 2005, Pages 449-455

Factors associated with mortality and long time survival in patients undergoing modified Bentall operations

Author keywords

Aorta, surgery; Aortic aneurysm; Aortic root; Bentall operation

Indexed keywords

ACUTE DISEASE; ADOLESCENT; ADULT; AGED; AORTA ANEURYSM; AORTA ARCH; AORTA CLAMPING; AORTA DISSECTION; AORTA GRAFT; AORTA ROOT; AORTA THROMBOSIS; AORTA VALVE DISEASE; AORTA VALVE REGURGITATION; ARTICLE; ASCENDING AORTA; CHRONIC DISEASE; COMPOSITE GRAFT; CONTROLLED STUDY; CORONARY ARTERY BYPASS GRAFT; FALSE ANEURYSM; FEMALE; FOLLOW UP; FORWARD HEART FAILURE; HEART ARREST; HEART SURGERY; HEMOFILTRATION; HUMAN; HYPOTHERMIA; INTENSIVE CARE UNIT; KIDNEY FAILURE; LENGTH OF STAY; MAJOR CLINICAL STUDY; MALE; MORBIDITY; MULTIPLE ORGAN FAILURE; OPERATION DURATION; POSTOPERATIVE HEMORRHAGE; PROSTHESIS INFECTION; SEPSIS; SURGICAL MORTALITY; SURGICAL TECHNIQUE; SURVIVAL RATE; SURVIVAL TIME; THROMBOEMBOLISM; TREATMENT INDICATION;

EID: 29244472008     PISSN: 00219509     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (15)
  • 1
    • 0026785634 scopus 로고
    • Composite valve graft rplacement of the proximal aorta: Comparison of techniques in 348 patients
    • Svensson LG, Crawford S, Hess, KR, Coselli JS, Safi HJ. Composite valve graft rplacement of the proximal aorta: comparison of techniques in 348 patients. Ann Thorac Surg 1992;54:427-39.
    • (1992) Ann Thorac Surg , vol.54 , pp. 427-439
    • Svensson, L.G.1    Crawford, S.2    Hess, K.R.3    Coselli, J.S.4    Safi, H.J.5
  • 2
    • 0036152044 scopus 로고    scopus 로고
    • Early and long-term outcome in patients undergoing aortic root replacement with composite graft according to the Bentall's technique
    • Prifti E, Bonacchi M, Frati G, Proietti P, Giunti G, Babatasi G et al. Early and long-term outcome in patients undergoing aortic root replacement with composite graft according to the Bentall's technique. Eur J Cardiothorac Surg. 2002;21:15-21.
    • (2002) Eur J Cardiothorac Surg. , vol.21 , pp. 15-21
    • Prifti, E.1    Bonacchi, M.2    Frati, G.3    Proietti, P.4    Giunti, G.5    Babatasi, G.6
  • 3
    • 0030693712 scopus 로고    scopus 로고
    • Aortic root replacement: Results using the St. Jude Medical/Hemashield Composite graft
    • Girardi LN, Talwalkar NG, Coselli JS. Aortic root replacement: Results using the St. Jude Medical/Hemashield Composite graft. Ann Thorac Surg. 1997;64:1032-5.
    • (1997) Ann Thorac Surg. , vol.64 , pp. 1032-1035
    • Girardi, L.N.1    Talwalkar, N.G.2    Coselli, J.S.3
  • 5
    • 0032700395 scopus 로고    scopus 로고
    • Replacement of the proximal aorta and aortic valve using a composite bileaflet prosthesis and gelatin-impregnated polyester graft (Carbo-seal): Earley results in 142 patients
    • Langley SM, Rooney SJ, Dalrymple-Hay MJ, Spencer JM, Lewis ME, Pagano D et al. Replacement of the proximal aorta and aortic valve using a composite bileaflet prosthesis and gelatin-impregnated polyester graft (Carbo-seal): earley results in 142 patients. J Thorac Cardiovasc Surg 1999;118:1014-20.
    • (1999) J Thorac Cardiovasc Surg , vol.118 , pp. 1014-1020
    • Langley, S.M.1    Rooney, S.J.2    Dalrymple-Hay, M.J.3    Spencer, J.M.4    Lewis, M.E.5    Pagano, D.6
  • 6
    • 0034163017 scopus 로고    scopus 로고
    • Aortic root replacement with coronary button re-implantation: Low risk and predictable outcome
    • Westaby S, Katsumata T, Vaccari G. Aortic root replacement with coronary button re-implantation: low risk and predictable outcome. Eur J Cardiothorac Surg 2000;17:259-65.
    • (2000) Eur J Cardiothorac Surg , vol.17 , pp. 259-265
    • Westaby, S.1    Katsumata, T.2    Vaccari, G.3
  • 9
    • 0027943062 scopus 로고
    • Aortic root replacement with a composite graft: Results of 69 operations in 66 patients
    • Aoyagi S, Kosuga K, Akashi H, Oryoji A, Oishi K. Aortic root replacement with a composite graft: Results of 69 operations in 66 patients. Ann Thorac Surg 1994;58:1469-75.
    • (1994) Ann Thorac Surg , vol.58 , pp. 1469-1475
    • Aoyagi, S.1    Kosuga, K.2    Akashi, H.3    Oryoji, A.4    Oishi, K.5
  • 10
    • 0014311521 scopus 로고
    • A technique for complete replacement of the ascending aorta
    • Bentall H, De Bono A. A technique for complete replacement of the ascending aorta. Thorax 1968;23:338-9.
    • (1968) Thorax , vol.23 , pp. 338-339
    • Bentall, H.1    De Bono, A.2
  • 12
    • 0035166384 scopus 로고    scopus 로고
    • Influence of technique of coronary artery implantation on long-term results in composite aortic root replacement
    • Panos A, Amahzoune B, Robin J, Champsaur G, Ninet J. Influence of technique of coronary artery implantation on long-term results in composite aortic root replacement. Ann Thorac Surg 2001;72:1497-501.
    • (2001) Ann Thorac Surg , vol.72 , pp. 1497-1501
    • Panos, A.1    Amahzoune, B.2    Robin, J.3    Champsaur, G.4    Ninet, J.5
  • 15
    • 0033385860 scopus 로고    scopus 로고
    • Aortic root replacement with the Carboseal composite graft: 7-year experience with the first 100 implants
    • Luciani GB, Casali G, Barozzi L, Mazzucco A. Aortic root replacement with the Carboseal composite graft: 7-year experience with the first 100 implants. Ann Thorac Surg 1999;68:2258-62.
    • (1999) Ann Thorac Surg , vol.68 , pp. 2258-2262
    • Luciani, G.B.1    Casali, G.2    Barozzi, L.3    Mazzucco, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.